6
Section 1
Model 752 and 752A Differential Pressure Transmitters
Specifications (cont'd)
Load Range
(includes line and receiver; see
4-20 mA ....................................... 50 ohms per volt above 12 VDC (to 2900 ohms
maximum)
10-50 mA ..................................... 20 ohms per volt above 12 VDC (to 1160 ohms
maximum)
Load Effect*
4-20 mA .......................................
±0.025% of factory-calibrated span per 100-ohms
change
10-50 mA .....................................
±0.05% of factory-calibrated span per 100-ohms
change
Power Supply Effect*
4-20 mA .......................................
±0.025% of factory-calibrated span per 1 Volt
change
10-50 mA .....................................
±0.05% of factory-calibrated span per 1 Volt change
Noise* .............................................
0.2% (peak-to-peak) maximum of factory-calibrated
span
Thermal Effect*(combined effect
on zero and span)...........................
±1.0% of factory-calibrated span per 100
º
F change
within the operating temperature range selected
Operating Temperature ................... 40
º
F to 135
º
F (standard), -15
º
F to +135
º
F (optional)
Max. Safe Working Pressure .......... 3000 psig
Static Pressure Effects*
1-30 psid range............................
±0.2% of factory-calibrated span per 1000 psig
30-200 psid range........................
±0.5% of factory-calibrated span per 1000 psig
200-500 psid range......................
±1.0% of factory-calibrated span per 1000 psig
Overpressure Effects*
1-30 psid range............................
±0.5% of factory-calibrated span per 1000 psig
30-200 psid range........................
±1.5% of factory-calibrated span per 1000 psig
200-500 psig range......................
±3.0% of factory-calibrated span per 1000 psig
Overpressure limit .......................... Up to 3000 psig on either side of DPU without
damage to unit
Process Connections...................... 1/4" and 1/2" NPT (female) on both high and low
pressure sides
Weight ............................................ 8 lb (basic)
Electrical Interface .......................... 1/2 inch conduit connections to internal screw termi-
nals (external junction box optional)
*Note: Turndown has a directly proportional effect on the indicated specifications. Zero
or span field adjustments beyond ±5% may affect indicated performance. Calibration is
by the end-point method with zero and full scale outputs held to ±0.5% of true calibrated
values.
IMPORTANT: The Model 752 and 752A transmitters have no integral electronic interfer-
ence suppression features. If an instrument is to be installed in an area
containing EMI/RFI sources and this interference cannot be tolerated,
take precautions to protect the transmitter signal. See also
. An optional EMI/RFI filter system is available upon
request.