10
Section 3
Model 351/352/353 Liquid Level Systems
Capillary Tubing Welding
Figures 3.1 through 3.3 present the information and procedures necessary to
weld the capillary tubing and tubing coupling.
Figure 3.1—1/4-in. OD capillary tubing welds
IMPORTANT: All parts are solution annealed 316 or 304 stainless steel. Please adhere
to the following welding practices:
(1) Weld type: GTAW fillet, 45 amps, 10 volts, 20 CFH (9.5 l/m) Argon
gas flow.
(2) Use 1/16” dia. Type 308 filler rod
Содержание 351
Страница 30: ...30 Section 6 Model 351 352 353 Liquid Level Systems Figure 6 3 Model S048 sensor ...
Страница 32: ...32 Section 6 Model 351 352 353 Liquid Level Systems ...
Страница 34: ...34 Section 6 Model 351 352 353 Liquid Level Systems ...
Страница 35: ...35 ...