There are several things to keep in mind when setting the Multi-ROI feature on the VC-12MC camera:
The sum of the Offset X value plus the Width value must not exceed the width (4096 on the VC-12MC) of
the camera
’s sensor.
The sum of the Offset Y value plus the Height value must not exceed the height (3072 on the VC-12MC) of
the camera
’s sensor.
The Offset X value must be a multiple of 8.
The Width value must be a multiple of 8 ranging from 24 to 4096.
The Offset Y and Height values must be a multiple of 4 ranging from 4 to 3072.
You need to set the regions in order. When you set a preceding region to OFF, all the succeeding regions
will be set to OFF automatically. For example, you have set four regions from 0 through 4. If you set the
region 1 to OFF, the region 2, 3 and 4 will be set to OFF.
You do not need to order the regions from top to bottom on the sensor. For example, you could place the
region 1 near the bottom of the sensor, the region 2 near the top, and the region 3 in the middle.
You can save (
Configurator
>
File
>
Save Setting
>
User 1
or
User 2
) the setting values for Multi-ROI to
parameter storage space and then load (
Configurator
>
File
>
Load Setting
>
From User 1 Space
or
From User 2 Space
) the values to the camera when desired.