Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
Confi guration>
Functions
Hold-to-run
Deactivated (Default)
On
Obstacle with motor stopped
With the function active, the operator remains stopped if the safety devices detect an obstacle. The function is active when the
gate is closed, open or after a complete stop.
Confi guration>
Functions
Obst. with motor stopped
Deactivated (Default)
On
Automatic closure
Set the time before automatic closure, once the opening travel end point has been reached or once the photocells have
caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
Confi guration>
Times
Automatic close
Deactivated (Default)
From 1 to 180 seconds
Automatic closing after either partial or pedestrian opening
Set the time before automatic closure after a partial opening command.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
Confi guration>
Times
Automatic partial close
Off
1 to 180 seconds (Default 10)
Apartment building mode
With the Partial Opening command (2-3P), the leaf M2 opens.
If an Open command (2-3) is then sent, both leaves open.
With the [Automatic closing] function set, leaf M1 closes after the selected automatic closing time, while leaf M2 moves to the
partial opening point set under [Partial opening adjustment].
If the partial opening command is given from input (2-3P), the [Automatic closing after either partial or
pedestrian opening] function must be deactivated.
To return to normal gate operation, send a closing command.
If the partial opening command is sent via a timer, after the set time the operator returns to normal operation
and the leaves close. See function [Create timer].
M1 opening delay time
Adjust the delayed opening of the fi rst leaf compared to the second.
Confi guration>
Times
M1 open delay
Off
1 to 10 seconds (Default 2)