CAME ZLX24S Скачать руководство пользователя страница 29

  

29

  - Manual 

FA01797-EN - 

 05/2022 -  © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. -  Translation of the original instructions

Содержание ZLX24S

Страница 1: ...Tel 39 0422 4940 Fax 39 0422 4941 info came com www came com DESCRIPTION OF PARTS KIT components 1 Control board ZLX24S 801QA 0060 801QA 0080 2 Control board holder 3 Terminal block with fuse compartm...

Страница 2: ...ng the safety devices 8 Memory Roll card connector 9 Terminal board for B1 B2 output 10 Connector for CAME KEY 11 RIO CONN card connector 12 Terminal board for CRP connection 13 RSE card connector 14...

Страница 3: ...is manual may be changed at any time and without notice Translation of the original instructions INSTALLATION A Control board support xing point B Fuse holder terminal block xing point Screws not prov...

Страница 4: ...ents of this manual may be changed at any time and without notice Translation of the original instructions ELECTRICAL CONNECTIONS Before working on the control panel cut off the mains power supply Alw...

Страница 5: ...this manual may be changed at any time and without notice Translation of the original instructions ZLJ24 control panel Blue cable White cable Red cable Black cable Orange cable Purple cable 120 230 V...

Страница 6: ...5 2022 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions White cable Black cable Orange cable Purple cable Cable not provide...

Страница 7: ...his manual may be changed at any time and without notice Translation of the original instructions ZL19N control panel Blue cable White cable Red cable Black cable Orange cable Purple cable Brown cable...

Страница 8: ...5 2022 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions White cable Black cable Orange cable Purple cable Cable not provide...

Страница 9: ...r status warning light 10 5 26 AC 3 The outputs deliver 24 V DC when the batteries start operating if they are installed Device Output Power supply V Power W Auxiliary contact B1 B2 24 24V AC DC Conne...

Страница 10: ...programming 2 Control device NO contact OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control device NO contact PARTIAL OPENING or PE...

Страница 11: ...he original instructions Signalling devices 1 Flashing beacon It ashes when the operator opens and closes 2 Additional light It increases the light in the manoeuvring area See Additional light functio...

Страница 12: ...the input Connect the safety devices to the CX and or CY and or CZ and or CK inputs If used the contacts CX CY CZ CK must be con gured during programming For systems with multiple pairs of photocells...

Страница 13: ...any time and without notice Translation of the original instructions DIR DELTA S photocells Standard connection Connection with safety test See Safety devices test function 10 TS 2 CX CY CZ CK 10 11 E...

Страница 14: ...slation of the original instructions DXR DLX photocells Standard connection Connection with safety test See Safety devices test function 10 TS 2 CX CY CZ CK 10 11 E E3 5 RX TX 10 11 OUT 10 11 SY 10 TS...

Страница 15: ...decrease values 3 ENTER button The ENTER button is used to perform the operations described below Access menus Con rm choice Outside the menu the ESC key stops the gate and the keys open and close th...

Страница 16: ...t switches deactivated the stop point is de ned by mechanical stops on the ground Stop in FA stop in FC Slowdown in FA FC Default Stop in FA slowdown in FC Input type FC FA N O Default N C N C for FA...

Страница 17: ...s Limit switch function Slowdown in FA FC Default Select the parameter if both microswitches are used for slowdown Stop in FA slowdown in FC Select the parameter if the opening microswitch is used as...

Страница 18: ...travel The panel will not accept motion commands except for the motor test Complete programming and check the warning and safety devices are working properly After powering up the system the rst manoe...

Страница 19: ...4N A5024N FROG A24 FROG A24E Default ATS F1024 F4024E F4024EP Con guration Motor settings Encoder Activated Default Off Con guration Motor settings Reduce speed Deactivated Default 1 to 50 Con guratio...

Страница 20: ...itch function Input type FC FA Motor power See the speci c parameters for each function Con guration Gate travel settings Opening speed 40 to 100 Default 70 Con guration Gate travel settings Closing s...

Страница 21: ...Closing slowdown speed 10 to 50 Default 40 Con guration Gate travel settings Slowdown AST control Deactivated Default Maximum thrust and low obstruction sensitivity Minimum Average Maximum Minimum thr...

Страница 22: ...ning photocells C3 Partial stop Only with Automatic close activated C4 Obstacle standby photocells C7 Reopen while closing sensitive edges C8 Reclose while opening sensitive edges C13 Reopen while clo...

Страница 23: ...Maximum Con guration Functions Thrust Deactivated Default On Con guration Functions Removing obstacles Deactivated Default On Con guration Functions B1 B2 output Bistable Monostable on from 1 to 180...

Страница 24: ...mp The lamp stays on during the manoeuvre Courtesy light The light switches on when a manoeuvre starts and remains on once the manoeuvre has nished for the time set under the function Courtesy time Co...

Страница 25: ...ck Con rm NO Con rm YES Manage users Self Learning Rolling Deactivated Default On Manage users Change mode Step by step Sequential Open Partial opening B1 B2 output Con rm NO Con rm YES Information FW...

Страница 26: ...ge to daylight saving time Winter changeover 1 hour on the last Sunday in October change to standard time Timer management Time format 24 hour 12 hour Timer management Create new timer Open Partial op...

Страница 27: ...ntrol board all saved users set times manoeuvre con gurations and calibration operations are deleted Import export data Save user data and system con guration data on a MEMORY ROLL card The stored dat...

Страница 28: ...ce test failure error E7 Operating time error E9 Consecutive obstacles detected during closing E10 Consecutive obstacles detected during opening E11 Maximum number of obstacles E12 Motor supply voltag...

Страница 29: ...29 Manual FA01797 EN 05 2022 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Страница 30: ...30 Manual FA01797 EN 05 2022 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Страница 31: ...31 Manual FA01797 EN 05 2022 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Страница 32: ...ntents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy Tel 39 0422 494...