P
age
34
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Closing slowdown point
Set the percentage of the total travel to be used for the M1 and M2 closing slowdown.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Closing slowdown point
Deactivated (Default)
1% to 50%
Opening slowdown speed
Set the M1 and M2 slowdown speed during opening (as a percentage of the maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
The parameter is only used with the [Opening slowdown point] function active.
Confi guration>
Gate travel settings
Opening slowdown speed
10% to 50% (Default 40%)
Closing slowdown speed
Set the M1 and M2 slowdown speed during closing (as a percentage of the maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
The parameter is only used with the [Closing slowdown point] function active.
Confi guration>
Gate travel settings
Closing slowdown speed
10% to 50% (Default 40%)
Slowdown AST control
Adjust the obstruction detection sensitivity during slowdown in percentage terms.
The parameter is only used if the opening or closing slowdown point is active.
Confi guration>
Gate travel settings
Slowdown AST control
Deactivated (Default)
Maximum thrust and low obstruction sensitivity.
Minimum
Average
Maximum*
(*)
Minimum thrust and high obstruction
sensitivity.
Customised
Customised closing
Customised opening
The personalised values to be used are expressed as a
percentage:
- from 10% (minimum thrust and high obstruction
sensitivity)
- to 100% (maximum thrust and low obstruction
sensitivity)