Dir/DeltaS

<- C1 ->

<- CX ->

p. 

9

 - M

an

u

al

 

FA

0

1

07

8

-E

N

 - 0

2

/2

0

18 © C

A

M

E S

.p.

A

. - T

ra

n

sl

ati

on of th

e o

rig

in

al

 in

str

u

cti

on

s

Connection for 

reopening during closing 

(N.C. contact).

 

- With safety devices such as photocells, sensitive safety-

edges or other devices. During closing, the contact triggers an inversion of movement until the gate is completely open.

If unused, set DIP-switch 9 to ON.

Safety devices 

with DIP-switch 8 OFF - DIP-switch 10 OFF

with DIP-switch 8 OFF - DIP-switch 10 ON

Connection for 

reclosing during opening 

(N.C. contact). 

- With safety devices such as photocells, sensitive safety-
edges or other devices. During the opening phases, the 
contact triggers an inversion of movement until the gate is 
completely closed.

Partial-stop connection (N.C. contact). - With safety 
devices such as photocells, sensitive safety-edges or 
other devices. Stops movement and sets up for automatic 
closing.

If unused, disable input CX with DIP-switch 8 set to ON.

Содержание ZA3N

Страница 1: ...Control panel for 230Vgearmotors ZA3N INSTALLATION MANUAL EN English FA01078 EN...

Страница 2: ...te any guided part that includes a pedestrian gate unless the latter can be activated only when the pedestrian gate is secured Make sure the anchoring spot is clear of any potential impacts that the a...

Страница 3: ...Make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules It should completely cut off the power supply according to category...

Страница 4: ...table The card providesand controls the following functions automatic closing following an opening command pre flashingby the movement indicator light obstructiondetection when gate is not moving at...

Страница 5: ...ted internally Colour of thetransformer and condenser cables white red black orange purple light blue Description of parts 1 Connection terminals 2 Control board fuses 3 Fuse for control devices and a...

Страница 6: ...57 IEC whereas indoors use H05VV F type cables that conform to 60227 IEC 48V 53 IEC When powered up to you may use FROR 20 22 II type cables that conform to standard EN 50267 2 1 CEI For the Encoder u...

Страница 7: ...otor with delayed opening Electolock connection 12V 15W max Terminals for powering the 24VA C accessories Control panel 230V A C 50 60 Hz ELECTRICAL CONNECTIONS AND PROGRAMMING Input voltage Gearmotor...

Страница 8: ...n made on the DIP switches see selecting functions DIP switches 2 and 3 Key switch selector and or opening button N O contact For commanding the gate to open Stop button N C contact For commandingthe...

Страница 9: ...to ON Safety devices with DIP switch 8 OFF DIP switch 10 OFF with DIP switch 8 OFF DIP switch 10 ON Connection for reclosing during opening N C contact With safety devices such as photocells sensitive...

Страница 10: ...osingcommand thegateleavesjoltinwards forasecond tohelpreleasetheelectriclockconnectedtoterminals11 S This is active only if the leaves are closed and at the end of the operating time or at the rst ma...

Страница 11: ...ontrol board AFTER CUTTING OFF THE MAINS POWER SUPPLY N B The control board recognizes the radiofrequency card only when it is powered up Saving CH1 Channel for direct commands to a feature of the gea...

Страница 12: ...SPOSAL Always make sure you comply with local laws before dismantling and disposing of the product The packaging materials cardboard plastic and so on should be disposed of as solid household waste an...

Отзывы: