CAME ZA3N Скачать руководство пользователя страница 4

204

254

274

133

184

p. 

4

 - M

an

u

al

 

FA

0

1

07

8

-E

N

 - 0

2

/2

0

18 © C

A

M

E S

.p.

A

. - T

ra

n

sl

ati

on of th

e o

rig

in

al

 in

str

u

cti

on

s

Intended use

Model

Operator

ZA3N

ATI - FAST - FERNI - FROG - KRONO

 Any installation and/or use other than that specified in this manual is forbidden.

Technical data

Type

ZA3N

Protection rating (IP)

54

Power supply (V - 50/60 Hz)

230 AC

Absorption when idle (mA)

60

Max. power* (W)

600

Casing material

ABS

Operating temperature (°C)

-20 to +55

Insulation class
* Overall power of the connected motors

Dimensions

Fuse table

To protect

Fuse type

Line (

)

5 A-F

Control board (

)

3.15 A-F

DESCRIPTION

Multifunction control panel for swing gates.
The control devicesand accessories run on 24V. 

 The accessories must not exceed 20W overall.

Allthe connection are quick-fuse protected (see table).
The card providesand controls the following functions:
- automatic closing following an opening command;
- pre-flashingby the movement indicator-light;
- obstructiondetection when gate is not moving at any point;
- adjustmentof the connected operator's torque;
- opening jolt.
The settablecontrol modes are:
- opening/closing;
- opening/closingin maintained action;
- partial opening;
-total stop.
The photocells, afterdetecting an obstruction, may trigger:
- reopening ifthe gate is closing;

- reclosing or partial stop if gate is opening;
- partial stop if gate is opening.
Specific trimmersregulate:
- the automaticclosing's intervention time;
- gearmotor M2'sclosing delay;
- the operating time. 
You can also connect:

gate open warning lights; - cycle lights;
- electric lock.

KEY

  This symbol shows which parts to read carefully.

  This symbol shows which parts describe safety issues
  This symbol shows which parts to tell users about.

The measurements, unless otherwise stated, are in millimeters.

Содержание ZA3N

Страница 1: ...Control panel for 230Vgearmotors ZA3N INSTALLATION MANUAL EN English FA01078 EN...

Страница 2: ...te any guided part that includes a pedestrian gate unless the latter can be activated only when the pedestrian gate is secured Make sure the anchoring spot is clear of any potential impacts that the a...

Страница 3: ...Make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules It should completely cut off the power supply according to category...

Страница 4: ...table The card providesand controls the following functions automatic closing following an opening command pre flashingby the movement indicator light obstructiondetection when gate is not moving at...

Страница 5: ...ted internally Colour of thetransformer and condenser cables white red black orange purple light blue Description of parts 1 Connection terminals 2 Control board fuses 3 Fuse for control devices and a...

Страница 6: ...57 IEC whereas indoors use H05VV F type cables that conform to 60227 IEC 48V 53 IEC When powered up to you may use FROR 20 22 II type cables that conform to standard EN 50267 2 1 CEI For the Encoder u...

Страница 7: ...otor with delayed opening Electolock connection 12V 15W max Terminals for powering the 24VA C accessories Control panel 230V A C 50 60 Hz ELECTRICAL CONNECTIONS AND PROGRAMMING Input voltage Gearmotor...

Страница 8: ...n made on the DIP switches see selecting functions DIP switches 2 and 3 Key switch selector and or opening button N O contact For commanding the gate to open Stop button N C contact For commandingthe...

Страница 9: ...to ON Safety devices with DIP switch 8 OFF DIP switch 10 OFF with DIP switch 8 OFF DIP switch 10 ON Connection for reclosing during opening N C contact With safety devices such as photocells sensitive...

Страница 10: ...osingcommand thegateleavesjoltinwards forasecond tohelpreleasetheelectriclockconnectedtoterminals11 S This is active only if the leaves are closed and at the end of the operating time or at the rst ma...

Страница 11: ...ontrol board AFTER CUTTING OFF THE MAINS POWER SUPPLY N B The control board recognizes the radiofrequency card only when it is powered up Saving CH1 Channel for direct commands to a feature of the gea...

Страница 12: ...SPOSAL Always make sure you comply with local laws before dismantling and disposing of the product The packaging materials cardboard plastic and so on should be disposed of as solid household waste an...

Отзывы: