P
age
19
- Manual
FA01768-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CX input
Associate a function with the CX input.
F2
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
r8 = Reclose while opening (sensitive edges with 8K2 resistor)
CY input
Associate a function with the CY input.
F3
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
r8 = Reclose while opening (sensitive edges with 8K2 resistor)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
F5
OFF (Default)
1 = CX
2 = CY
3 = CX+CY
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
OFF (Default)
ON
Command 2-7
Associate a command to the connected device on 2-7.
F7
0 = Step-by-step (default)
The first command is to open and the second to close.
1 = Sequential
The first command is to open, the second to STOP, the third to close and the fourth to STOP.
2 = Open
3 = Close
Command 2-3P
Associate a command to the connected device on 2-3P.
F8
1 = Partial opening (Default)
The degree of partial opening is set as a percentage using the [F36 – Adjusting the partial opening] function.
2 = Open
Obstacle with motor stopped
With the function active and the operator stopped, an open or close command is not performed if the safety devices detect an obstacle.
F9
OFF (Default)
ON
Содержание VER10DMS
Страница 1: ...VER10DMS VER13DMS FA01768M04 IT Italiano EN English FR Français RU Русский ...
Страница 2: ......
Страница 29: ...Garage door operators VER10DMS VER13DMS INSTALLATION MANUAL FA01768 EN EN English ...
Страница 30: ......
Страница 57: ...Automatismes pour portes de garage VER10DMS VER13DMS MANUEL D INSTALLATION FA01768 FR FR Français ...
Страница 58: ......
Страница 85: ...Автоматика для гаражных ворот VER10DMS VER13DMS РУКОВОДСТВО ПО МОНТАЖУ FA01768 RU RU Русский ...
Страница 86: ......