Before proceeding with the installation, it is necessary to:
• Make sure the area selected for the mounting of the base and for the unit itself is hazard free;
• Provide for a suitable omnipolar disconnection device with contacts more than 3 mm apart, and independent (sectioned off) power
supply;
• Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as
compared to the other conductive parts inside;
• Make sure that the point where the gearmotor is fastened is protected from impact and that it is sturdy. The fastening must be carried
out using screws and/or rivets that are suitable for the type of surface;
•
Make sure that any connections inside the container (made for the continuity of the protection system) are provided with additional
insulation compared to the other conductive parts inside;
• Make sure that the door has a sturdy enough structure, that the hinges be in proper working order and that there is friction between
moving and fixed parts;
The installation must be carried out by export, qualified personnel in total compliance with the norms in effect.
Size measurements
Installation
Preliminary checks
Connections
Type of cable
Length of cable
1 < 10 m
Length of cable
10 < 20 m
Length of cable
20 < 30 m
230V power supply
FROR CEI 20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Flashing lamp
2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photocell transmitters
2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photocell receivers
4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V power supply to accessories
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control and safety devices
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Antenna connection
RG58
max. 10 m
Cable list and minimun thickness
N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual
power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.
When connecting products other than those mentioned in this manual please see the documents provided with the products themselves.