background image

L

N

+

E

-

10

2

1

11

1,6 A-F

L

N

+          -

+

E

-

A

B

GND

EbA

EbA

EbI

EbI

10

S2

S1

2

EM

4

3

2

1

11

1,6 A-F

1

5

4

6

3

2

2

7

8

9

10

TOR100A

TOR100B

L

N

L

N

TOR100A

TOR100B

11

Pa

g

8

  - M

an

u

al

 c

od

e: 

11

9

G

3

7

8

2

E

N

11

9

G

3

7

8

2

E

N

 ve

r.

 

1

  

1  

0

1/

2

0

14  © C

A

M

E

 c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

 by C

A

M

E

 C

an

ce

lli

 A

u

to

m

ati

ci

 S

.p.a.

FUSE TABLE

TOR100A

TOR100B

Line fuses (A)

1.6 (230 V)

3.15 (120 V)

Accessories:

1.6

6.3

230 V AC transformer power supply
(default connection)

120 V AC transformer power supply
(Reverse cables 

 and 

)

Ref.

Description

L1T = White

L2T = Red

Black (insulated)

Ref.

Description

L1T = White

Red (

insulated)

L2T = Black

Replace the 1.6 A line fuse with a 3.15 A unit.

 

*

 Must be performed by the installer!

ELECTRICAL CONNECTIONS

Description of the components

1. Transformer

2.  Transformer terminal block

3. Accessory 

fuse

4.  Transit sensor terminal block

5. Line 

fuse

6.  Power supply terminal block

7.  Control ans safety device terminal block

8.  Electric lock terminal block

9.  Arrow indicators terminal block 

PSBPS10

PSBPS10

PSBPS08

PSBPS08 PSBPS09

PSBPS09

10.  Arm drop power supply terminal block 

PSBPS10

PSBPS10

 

 Before intervening on the control board, disconnect the line voltage.

Control board supply (V - 50/60 Hz): 120 - 230 AC.
Control device power supply: 24 V AC

The total power of the accessories should not exceed 35 W.

 

The output power at 24V AC

 

is SELV and entails in a risk of electric shock.

All the connections are protected by quick fuses.

Power supply

120 - 230 V AC (50 / 60 Hz)

Содержание TWISTER LIGHT PSBPS07N

Страница 1: ...INSTALLATION MANUAL English EN 119G3782EN TRIPOD TURNSTILES TWISTER LIGHT PSBPS07N PSBPS08 PSBPS09 PSBPS10 ...

Страница 2: ... identification data must be clearly visible Before connecting the turnstile to the power supply make sure the identification data corresponds to the mains data The turnstile must be connected to an effective compliant earthing system The manufacturer disclaims any liability for the use of non original products this also results in the invalidation of the warranty All hold to run commands must be pl...

Страница 3: ...nst climbing over Automatic tripod release in the event of a blackout 001PSBPS10 AISI 304 steel bidirectional electromechanical turnstile with scotch brite finish complete with control board hydraulic damper and LED arrow indicators lights plus arm drop system Automatic tripod release in the event of a blackout Technical data Model PSBPS07N PSBPS08 PSBPS09 PSBPS10 Protection rating IP 44 Control p...

Страница 4: ... and washers for fixing the legs 13 Screw for fixing the casing 1 Legs 2 Tripod 3 Steel housing 4 Casing 5 Casing cover 6 Top cover 7 LED arrow indicatorss 8 Mechanism 9 TOR100A control panel 10 Cover lock 11 Screws and washers for fixing the legs 12 Screw for fixing the casing 13 Photocell holder crosspiece 14 Security photocells 15 Protection against climbing over sensors 1 Legs 2 Tripod 3 Sheet...

Страница 5: ...time without prior notice by CAME Cancelli Automatici S p a Dimensions Example of a system 1 Tripod turnstile 2 Arrow indicators 3 Junction box 4 Barrier Examples of use Standard installation Wall flanking installation Multiple installation A turnstile regulated exit should not be considered an emergency exit Always provide an exit for emergency situations and for the physically impaired Recommend...

Страница 6: ...e table must be re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please refer to the documentation provided with said products Connection Cable type Cable length 1 10 m Cable length 10 20 m Cable length 20 30 m 230 V power supply control panel FROR CEI 20 22 IEC EN 50267 2 1 3G x 1 5 mm 2 3G x 1 5 mm 2 3G x 1 5 mm 2 Accessory powe...

Страница 7: ... screws M10x60 and flat head washers Drill the marked holes and insert the dowels into them The floor on which the turnstile is fixed must be perfectly level Securing the turnstile The turnstile ancoring spot depends on the size of the gap and the possible accessories to be connected Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm...

Страница 8: ...d L2T Black Replace the 1 6 A line fuse with a 3 15 A unit Must be performed by the installer ELECTRICAL CONNECTIONS Description of the components 1 Transformer 2 Transformer terminal block 3 Accessory fuse 4 Transit sensor terminal block 5 Line fuse 6 Power supply terminal block 7 Control ans safety device terminal block 8 Electric lock terminal block 9 Arrow indicators terminal block PSBPS10 PSB...

Страница 9: ...without prior notice by CAME Cancelli Automatici S p a Devices already connected all models White Brown Green Transit sensor White Red 230 V AC White Black 120 V AC Blue Blue Transformer Red Red Red Red Electric lock Photocell Photocell Photocells PSBPS09 PSBPS09 Sensor Sensor Protection against climbing over sensors PSBPS09 PSBPS09 Buzzer PSBPS09 PSBPS09 Devices to be connected Arrow indicatorss ...

Страница 10: ...llows clockwise unlocking of tripod The tripod will lock automatically after a fixed time of 10 s Release button N C contact Allows the tripod to be unlocked for rotation in both directions Terminal block for 24 V AC powering of accessories with maximum current and power draw of 250 mA and 35 W respectively FINAL OPERATIONS Wait 10 seconds before performing any operation after connecting the turnst...

Страница 11: ... by acting on the tripod and while screwing unscrewing the damper adjust braking force of the rotating mechanism it must smoothly reach the end run during slowdown Make sure that slowdown is as expected for both clockwise and anti clockwise rotation Lock the hydraulic damper by tightening the bolt ADJUSTING THE HYDRAULIC DAMPER Put the cover on and close the lock with the key MAINTENANCE Before an...

Страница 12: ...n engaged Invite the person to stop leaning on the arm and try again Contact service Check the validity of the release command The tripod does not slow down at end run The hydraulic damper is not functioning properly Adjust the damper The turnstile is unlocked after passage The transit sensor is incorrectly positioned The transit sensor is damaged Check the position of the transit sensor Contact s...

Отзывы:

Похожие инструкции для TWISTER LIGHT PSBPS07N