![CAME SDN Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/came/sdn-series/sdn-series_quick-start-manual_4061315004.webp)
CAME Australia Pty Limited
Automatic Gates
– Access Control – Parking Equipment - Bollards
CAME Australia Pty Limited ABN 31 116 251 024
Unit 55, 11-21 Underwood Road, Homebush NSW 2140
T: (02) 9746 9991 F: (02) 9746 8891 W: www.came.com.au
Wiring of DIR10 and Delta SE*
C.B
10
2
C1
Rx
10
2
C
NC
Tx
Tx
2
Tx
*Reminder: Turn off dipswitch on Control Board
Wiring of DOC-E and DELTA E*
C.B
10
11
2
C1
Rx
+
-
2
NC
Tx
+
-
AMICO
1.
Insert all wires between motors and CB, unlock motor using trilobed key
2.
Set limits on operators, lock motor using trilobed key
3.
Insert AF43S card
4.
Connect power lead to L and N terminals, turn power on
5.
Turn on dipsw 9 & 10 (on the 10 dipsw assembly) and turn on dipsw 1 (on the 2 dipsw assembly) *
6.
Select Ch1, then press desired button on transmitter
7.
Press Open Motor button, if polarity is right then the gate will open, if not swap M + N
8.
Open gate leaves to 45 degrees using Open Motor button
9.
Press setup, each gate leaf will cycle and set themselves
*For Amico set dipsw 7 ON, for Frog J set dipsw 7 OFF