TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Applicable directives:

Presence

Typical response time: < 200 ms (max. 500 ms)

Active infrared with background analysis

Spot: 5 cm x 5 cm (typ)

Number of spots: max. 24 per curtain

Number of curtains: 2

Solid-state-relay (potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Holdtime: 0.3 to 1 s

Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms

EN 12978 
EN ISO 13849-1:2008 PL «c» CAT. 2

(under the condition that the door control system 
monitors the sensor at least once per door cycle)

IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8; 
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1

Motion

Min. detection speed: 5 cm/s

Microwave doppler radar

Transmitter frequency: 24.150 GHz

Transmitter radiated power: < 20 dBm EIRP

Transmitter power density: < 5 mW/cm

2

Solid-state-relay (potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

  - in switching mode:   NO/NC

  - in frequency mode:   pulsed signal 

 

 

(f= 100 Hz +/- 10%) 

Galvanically isolated current source

No detection: current source ON

Open circuit voltage: 6.5 V

Output voltage available at 10 mA: 3 V min.

Typical load: up to 3 optocouplers in series

Detection: current source OFF

Open-circuit remained voltage: < 500 mV

EN 12978 
EN ISO 13849-1:2008 PL «d» CAT. 2
EN 16005:2012 Chapter 4.6.8; 
DIN 18650-1:2010 Chapter 5.7.4; AutSchR
BS 7036-1:1996 Chapter 7.3.2

(only applicable for relay output in frequency mode 
and current source output)

Detection mode:

Technology:

Output:

Test input:

Norm conformity:

12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%  

(to be operated from SELV compatible power supplies only)

< 2.5 W
2 m to 3.5 m

 

(local regulations may have an impact on the acceptable mounting height)

-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU

M

R

8

7

0

0 / F

A

0

0

3

61

M

0

O

ri

g

in

al

 i

n

st

ru

ct

io

n

s

 I

X

IO

-DT

3 / 4

2

.8

6

3

8 / v

1 - 0

2

.1

6

Came S.p.A. hereby declares that MR8700 is in conformity with the basic requirements and the other relevant provisions 

of the directives 1999/5/EC, 2006/95/EC and 2006/42/CE.

Only for EC countries: According to the European Guideline 2012/19/EC for Waste Electrical and Electronic Equipment 

(WEEE)

Original upon request.

buy

-

to

-

sell

 

product

 

SAFETY INSTRUCTIONS

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery 

directive 2006/42/EC. 
Only trained and qualified personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by 
unauthorized personnel. Avoid touching any electronic and optical components.

Содержание MR8700

Страница 1: ...b 9 IR curtain angle adjustment knob Opening safety sensor for automatic sliding doors according to EN 16005 and DIN 18650 including emergency exits ENGLISH User s Guide for product version 0400 and h...

Страница 2: ...ALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed v...

Страница 3: ...eight of the sensor In emergency exits the full door width must be covered GREEN BROWN YELLOW WHITE PINK GREY RED BLUE YE BK WH BK POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR...

Страница 4: ...ld always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settin...

Страница 5: ...s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shop...

Страница 6: ...ter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted...

Страница 7: ...sk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be h...

Страница 8: ...up to 3 optocouplers in series Detection current source OFF Open circuit remained voltage 500 mV EN 12978 EN ISO 13849 1 2008 PL d CAT 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 Aut...

Отзывы: