OVERVIEW OF SETTINGS
Back
More
RAD: IMMUNITY
RAD: DIRECTION
RAD: HOLDTIME
IR: WIDTH
IR: NUMBER
IR: PRESENCE TIME
IR: OUTPUT
REDIRECTION
SMART DAISY CHAIN*
FACTORY RESET
DOOR BELL*
More
Back
Back
More
PRESETTINGS
RAD: FIELDSIZE
RAD: OUTPUT
IR: IMMUNITY
IR: FREQUENCY
More
Back
ZIP CODE all parameter settings in zipped format
(see application note on ZIP CODE)
ID #
unique ID-number
ERROR LOG last 10 day indication
IR: SPOTVIEW view of spot(s) that trigger detection
IR: C1 ENERG signal amplitude received on curtain 1
IR: C2 ENERG signal amplitude received on curtain 2
POWERSUPPLY
supply voltage at power connector
OPERATINGTIME power duration since first startup
RESET LOG
delete all saved errors
PASSWORD
LCD and remotre control password
(0000= no password)
LANGUAGE
language of LCD-menu
ADMIN
enter code to access admin mode
standard critical
env.
shopping
street
For conformity to EN 16005 or DIN 18650 at a
mounting height of 2.8 or more, use values 6 and 7.
For conformity to BS 7036 at a mounting height
of 2.2 m or more, use values 6 and 7.
Sensors mounted close to each other should
have a different frequency.
increased immunities, 1 curtain
increased immunities, redirection = motion and presence
factory values for radar immunity, IR immunity, IR number and redirection
small
large
bi
uni
uni
AWAY
low
0.5 s
1 s
2 s
3 s
4 s
5 s
6 s
7 s
8 s
9 s
uni
PRM
bi
auto
uni
auto
PRM
auto
PRM: for persons with reduced mobility
AWAY: unidirectional motion away from sensor
auto: automatic adaptation of field size (small shops)
service
mode
motion 15 s
30 s
1
min
2
min
5
min
10
min
motion
motion
or
presence
motion
and
presence
opening output is active in case of: 0 motion detection
1 motion
or
presence detection
2 motion
and
presence detection
20 min 60 min infinite
service mode = no IR detection during 15 minutes (maintenance).
This value excludes conformity of the door system to EN 16005 and DIN 18650.
high
min. value for DIN18650: 1 min
min. value for EN16005: 30 s
not allowed when the sensor is used in emergency exits
BASIC
ADV
ANCED
DIAGNOSTICS
freq: frequency output
current: current output
NO: normally open
NC: normally closed
Always additionally adjust
the arrow position on the
sensor with a screwdriver.
excludes conformity of the door system
according to EN 16005 / DIN 18650 / BS 7036
freq
NC
current
NC
NO
NC
NC
NC
NC
NO
NO
NO
freq
NC
current
NC
NO
NC
NC
NC
NC
NO
NO
NO
NO: normally open
NC: normally closed
low
normal
high
normal
high
higher highest
< 2.8 m
> 2.8 m
full
reset
partial
reset
partial: outputs are
not reset
1/2
: 1
st
sensor in chain of 2;
2/2
: 2
nd
sensor in chain of 2
1/3
: 1
st
in chain of 3;
2/3
: 2
nd
in chain of 3;
3/3
: 3
rd
in chain of 3
off
* Setting in combination with an accessory (see p. 1).
For more information see user’s guide of accessory.
factory value
radar
off
off
0.05 s 0.10 s 0.25 s
0.50 s 0.75 s
1 s
1.5 s
2 s
5 s
M
R
8
7
0
0 / F
A
0
0
3
61
M
0
6
☜☞
I
X
IO
-DT
3 / 4
2
.8
6
3
8 / v
1 - 0
2
.1
6