background image

14

1

3

7

6

4

12

13

15

16

12

10

8

5

9

11

2

Pa

g.

 

55

  - M

an

u

al

 c

od

e: 

11

9

G

2

5

11

9

G

2

5

 ve

r.

 

7.

2

7.

2

  1

1/

2

0

11  © C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

 in

sta

lla

tio

n m

an

u

al

 a

re s

u

sc

ep

tib

le to

 c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 s.p.a. to n

otify u

se

rs.

ENGLISH

 1 -  GARD group
 2 -  Control panel  
 3 -  Aluminium boom
 4 -  Red reflecting strips
 5 -  Antenna
 6 -  Protective rubber
 7 -  Warning lamps
 8 -  Motion warning flashing light

 9 -  Keypad selector switch

10 -  Emergency batteries
11 -  Photocell post
12 -  Safety photocells
13 -  Magnetic card reader post
14 -  Magnetic card reader
15 -  Fixed rest
16 -  Magnetic loop

N.B.:  An evaluation of the size of the cables with lengths other than the data in the table must be made based on the eff ective 
absorption of the connected devices, according to the instructions indicated by the CEI EN 60204-1 standards.
For connections that require several loads on the same line (sequential), the size given on the table must be re-evaluated based on 
actual absorption and distances.

5.3 Cable list and minimun thickness

5.4 Standar installation

Connections

Type of 

cable

Length of cable

1 < 10 m

Length of cable

10 < 20 m 

Length of cable

20 < 30 m

230V 2F power supply

FROR CEI 

20-22 

CEI EN 

50267-2-1

3G x 1,5 mm

2

3G x 2,5 mm

2

3G x 4 mm

2

Photoelectric cells TX

2 x 0,5 mm

2

2 x 0.5 mm

2

2 x 0,5 mm

2

Photoelectric cells RX

4 x 0,5 mm

2

4 x 0,5 mm

2

4 x 0,5 mm

2

24V power supply accessory

2 x 0,5 mm

2

2 x 0,5 mm

2

2 x 1 mm

2

Safety and control divices

2 x 0,5 mm

2

2 x 0,5 mm

2

2 x 0,5 mm

2

Antenna connection  

RG58

max. 10m 

Metallic mass detector

(see documents provided with product) 

Содержание G4000

Страница 1: ...G4000 G4001 G4000N INSTALLATION MANUAL STREET BARRIER AUTOMATION English EN 119G25EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ......

Страница 4: ...Joint for the G0401 G0468 Support for applying DOC series photocells to cabinet G0469 Support for applying the ashing light to the cabinet LB38 Battery card for connecting 3 12V 7Ah batteries Importa...

Страница 5: ...thick sheet metal cabinet with galvanised varnished finish G4000 RAL 2004 G4000N RAL rough grey or 2 mm thick satin polished stainless steel G4001 ready to fit all accessories Inspection door with cus...

Страница 6: ...lation it is necessary to Make sure the area selected for the mounting of the base and for the unit itself presents no hazards Provide for suitable omnipolar disconnection device with more than 3 mm b...

Страница 7: ...a in the table must be made based on the effective absorption of the connected devices according to the instructions indicated by the CEI EN 60204 1 standards For connections that require several load...

Страница 8: ...ng clamps at the base Prepare a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections N B the number of tubes depends on the type of system and the accessories...

Страница 9: ...e right length and secure via the A boom supporting attachment using the four supplied bolts Check the horizontal and vertical positions by adjusting the B C internal travel stops 5 7 Balancing the bo...

Страница 10: ...ngle 4 Now tighten the locknut and lock the gear motor M12 rh jointed rod M12 nut M12 lh eye rod Pull force WARNING Unlocking the barrier may be dangerous for users if the boom is wrongly secured duri...

Страница 11: ...he bar stops during closing the bar reverses its direction until it opens completely automatic closure is thus activated Caution after three consecutive direction reversals the bar will remain up and...

Страница 12: ...matici s p a to notify users ENGLISH Deceleration Speed Max Min Max Avg Min 1 Terminal boards for external connections 2 Line fuse 3 Accessories fuse 4 Select Function dip switch 5 Radiofrequency term...

Страница 13: ...tomatici s p a to notify users ENGLISH 6 2 Electrical connections The swing joint in the picture which is factory made is for a left hand barrier see par 5 8 24V d c Motor Gearmotor endstop Closing mi...

Страница 14: ...and or button connection N O contact Boom opening and closing command Pressing the button inverts movement of the boom Check position of Jumper n 12 page 10 as shown in the gure Opening button N O co...

Страница 15: ...within the range of the safety devices If unused set Dipswitch 8 to ON DIR photocells DIR photocells Safety devices DOC photocells DOC photocells Contact N C for immediate closing If not used position...

Страница 16: ...e inversion enabled with radiofrequency card slot 3 ON 24V voltage in output on terminals 10 E during movement cycles and when in the barrier closed position enabled 3 OFF 24V voltage in output on ter...

Страница 17: ...e at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Lock the radiofrequency card into the electronic card AFTER CUTTING OFF THE POWER SUPPLY or after disconn...

Страница 18: ...a to notify users ENGLISH Radio card PROG Keep pressed the PROG button on the electronic board The LED light will ash Press the button of the transmitter to be memorie The LED light will stay lit to s...

Страница 19: ...automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH De...

Страница 20: ...by accident In the event of anomalous behaviour stop using the operator immediately Danger of crushing hands Danger High voltage No transit during operation Important safety instructions 10 Maintenan...

Страница 21: ...automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Pe...

Страница 22: ...ator name Date of job Technician s signature Requester s signature Job performed ________________________________________________________________________________________ ______________________________...

Страница 23: ...ervice companies for proper disposal Prior to disposal it is always advisable to check speci c regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 10 3 Problem solving MALFUNCTION...

Страница 24: ...informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da empresa...

Отзывы: