background image

Pa

g. 

9

  - M

an

ua

l c

od

e: 

11

9A

V3

1

 v

er

2.

0

  0

9/

20

10  © C

AM

E c

an

ce

lli a

ut

om

at

ic

i s

.p

.a

. - 

Th

e d

at

a a

nd i

nf

or

m

at

io

n r

ep

or

te

d i

n t

hi

s i

ns

ta

lla

tio

n m

an

ua

l a

re s

us

ce

pt

ib

le t

o c

ha

ng

e a

t a

ny t

im

e a

nd w

ith

ou

t o

bl

ig

at

io

n o

n C

AM

E c

an

ce

lli a

ut

om

at

ic

i s

.p

.a

. t

o n

ot

ify u

se

rs

.

5.5 Assembly diagram

Fig.3

2.64” in

2.6” in

6.

3”

 in

4”

 in

2.

4”

 in

.1

2”

 in

5.6 Installing the unit

- Check the efficiency of both moving and non-moving parts on the structure that will be supporting the operator.

- Determine, depending on the type of supporting structure and desired opening, the exact position of the motor assembly 

by following the standard applications shown.

- Set up a closing end stop and an opening end stop (fig. 4, p. 5)

- Dig, depending on the size of the assembly, a foundation pit in the chosen spot (Fig. 3)

- Prepare a drainage system in the foundation, to drain away any water leaks which may cause oxidation (fig 3 – part.1)

- The foundation box makes for quick and easy setting up of the assembly.  Place it inside the pit with the pin aligned to 

the upper hinge (Fig. 3 – part. 2), sink it into the cement (Fig. 3 – part. 3) making sure it is perfectly levelled and that the 

upper edge is 1 inch above ground level (Fig. 3 part. 4)

- Plan for the route of the electrical cables according to the command and safety instructions using the apposite hole on 

the box (Fig. 3 – part. 5)

- Grease the rotation pins of the foundation box and the gate attachment lever; the hinge and pin lever must be aligned

- Position the gate leaf between the upper hinge and the pin lever; the hinge and pin lever must be aligned

- Secure the pin lever to the gate leaf, by welding spots from 1 to 1.5 inches apart along the contact surface.  

Avoid any welding near the threaded screws (Fig. 3 – Part. 6).

Fig.2

- Screw the M10 x 100 (A) and the M10 (B) bolt onto the  

gearmotor arm as shown in fig. 4-1 (left HAND installation) 

and fig. 4-2 (right HAND installation)

- Affix the gearmotor to the foundation box using the threaded 

pins and securing it using the provided bolts and washers

-  Insert  the  (C  )  transmission  lever  between  the  motor  arm 

and  the  box  lever  and  electronically  shut  the  gate  against 

the closing end stop.  Adjust screw (A) until it touches the (C) 

transmission lever.  

- When testing, adjust the screw so as to allow proper closing 

pressure of the gate leaf and allow its re-hooking during the 

mechanism’s release procedure.

- Once adjustment is complete, secure the (B) nut.

Fig.4

RT

LF

Fig.4-1

Fig.4-2

A

B

C

C

B

A

LF

RT

Содержание FROG series

Страница 1: ...INSTALLATION MANUAL FROG A 24U IN GROUND OPERATOR FOR SWING GATES FROG SERIES ...

Страница 2: ... openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 1 22m above the ground to prevent a 2 1 4 inch 57 2mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position 3 All exposed pinch points are eliminated or guarded 4 Guarding is supplied for...

Страница 3: ... the risk of entrapment or obstruction exists such as the leading edge trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hardwired contact sensor shall b...

Страница 4: ...urned freight prepaid to CAME AMERICAS AUTOMATION LLC 11345 NW 122nd Street Medley Florida 33178 IMPORTANT Obtain a Return Goods Authorization RGA number before returning item s to our facilities by submitting a warranty claim and request for RGA with our customer service department Products shipped without an RGA number will not be accepted Replacements or repaired parts are covered by this warra...

Страница 5: ...ill be no more than the amount you paid for the product that is the subject of a claim This is the maximum amount recoverable under this warranty The limitations in this section shall apply whether or not the alleged breach or default is a breach of a fundamental or material condition or term or a fundamental or material breach CAME AUTOMATION GATES UL 325 CLASSES CLASS DESCRIBTION DUTY CYCLE FROG...

Страница 6: ...TALLERS 2 2 Limits to use This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S p a and complies with current safety regulations The operator is made up of a foundation box a release assembly a gearmotor and a transmission arm Zinc plated press forged fondation box for underground installation On the inside is the release assembly with a customized manual release key and the ge...

Страница 7: ...lar cut off device with contacts more than 3 mm apart and independent sectioned off power supply Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage Fit tubing to drain away any water leaks which may cause oxidation Make sure that any connections inside the case that provide continuance to the protective circuit be fi...

Страница 8: ...w and distances When connecting products that are not described in this manual please refer to the instructions that come with said products 5 3 Cable list and minimum thickness Connections Type of cable Length of cable 3 32ft Leng cable 32 65ft Leng cable 65 100ft Controlpanelpowersupply230V UL LISTED CABLE WIRE 3G x 14AWG 3G x 14AWG 3G x 14AWG Motor power supply 24V 3 x 20AWG 3 x 20AWG 3 x 20AWG...

Страница 9: ...d that the upper edge is 1 inch above ground level Fig 3 part 4 Plan for the route of the electrical cables according to the command and safety instructions using the apposite hole on the box Fig 3 part 5 Grease the rotation pins of the foundation box and the gate attachment lever the hinge and pin lever must be aligned Position the gate leaf between the upper hinge and the pin lever the hinge and...

Страница 10: ...rt 3 consult the documentation pertinent to the relative items for the release procedure Note Release operations need to be carried out during emergency procedures and with the power disconnected 3 Fig 5 Fig 5 A Fig 5 B A4366 A4364 A4365 We suggest making the gearmotor cable connections in shunt boxes For further information concerning the functions see the technical documentation for the ZLJ24U c...

Страница 11: ...e limit stop s stopping zone Prepare a 2 x1 inch template and hold it up against one of the two mechanical stops as shown in fig 8 adjustment is to be made either on the closing endstop or opening endstop Activate the gate either using a command button or the remote control and turn the OP TIME TL trimmer clockwise until the gate leaf inverts its direction just as it touches the obstacle template ...

Страница 12: ...otentially dangerous The manufacturer cannot be held liable for any damages resulting from wrongful erroneous or negligent uses Avoid working close to the hinges or other moving mechanical parts Stay out of the opening closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Do not allow children to pla...

Страница 13: ...edures cut off the main power to prevent possible accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam and that the gate motion is...

Страница 14: ...ate of job Technician s signature Requester s signature Job performed_____________________________________________________________________________________ ________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s signature Requester s signature Job performed______________________________________________...

Страница 15: ...teproductsandmaybedisposedof easily keeping in mind recycling possibilities Prior to disposal it is always advisable to check specific regulations in force in the place of installation PLEASE DISPOSE OF PROPERLY PRODUCT DISPOSAL Our products are made up of various types of materials Most of them aluminium plastics iron electrical wires etc may bedisposedofinnormalgarbagecollectionbinsandcanberecyc...

Страница 16: ...ion on CAME cancelli automatici s p a to notify users CAME AMERICAS AUTOMATION LLC 11345 NW 122nd STREET MEDLEY FL 33178 Tel 305 433 3307 Fax 305 396 3331 Manual code 119AV31 ver 2 0 09 2010 CAME cancelli automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ...

Отзывы: