3
E
last 5 error messages (displayed by pressing “Data”)
r
current resistances of the sensors (kOhm): 1, 2, 4, 6, 8, 10, 12 or 14
S
shows the state of output 1:
output activated, 1 = okay, current flow; E = error, no current flow
(press “Data”) output deactivated, 0 = no current flow; E = error, current flow
S
shows the state of output 2:
output activated, 1= okay, current flow; E = error, no current flow
(press “Data”) output deactivated, 0 = okay, no current flow; E = error, current flow
S
shows the state of both outputs:
outputs activated, 1 = okay, current flow; E = error, no current flow
(press “Data”) outputs deactivated, 0 = okay, no current flow; E = error, current flow
C
shows the current configuration (active inputs):
001 = both inputs 1 and 2, 002 = only input 1, 003 only input 2
h
The holding time (extension of the output signal):
001 = none, 002 =100 ms, 003 = 200 ms, 004 = 500 ms, 005 = 1000 ms
C
configuration: entering into the configuration mode by pressing “data”
→
chap. 4.3
Enter Diagnostic menu:
Press “Mode” and “Data” buttons simultaneously for
2 seconds
→
Status LED flashes orange
To see the next parameter, press “Mode”, Data query
(Mode E and r): press “Data”
Exit Diagnostic menu:
Press “Mode” button for 2 seconds
Errors flash
r
Resistors
S
Output 1
S
Output 2
S
both
outputs
C
Configu-
ration
h
Fall-delay
time
C
Configu-
ration
Error 5
latest
1
value
1
1or E
1
1 or E
11
11 or E
C
001
h
002
con
Error 4
2
value
0
0 or E
0
0 or E
00
00 or E
con
(flashing)
Error 3
Error 2
Error 1
End
4.4 Diagnostic menu
(read only)
Data
Back to
start
Mode
›
›
›
›
Back
to top
›
›
›
›
›
›
›
›
›
›
2 sec
Access Configuration
(see chapter 4.3)
›
›
›
›
›
›
›
›
›
›
›
›
›
›
›
{
›
E
Function test
• Press sensor 1, check LED (orange), display (P
,
1). Check if output 1 is open.
• Release sensor
• If present, press sensor 2, check LED, display (P
, 2). Check if output 2 is open.
• Release sensor
After successful testing, the system is ready for operation.
Display: A and two flashing dots
4.5 Function test
Outputs
Contacts
Unpowered
Sensor 1
idle
Sensor 1
actuated
Sensor 2
idle
Sensor 2
actuated
Sensor 1 + 2
idle
Fault
Safety output 1
OPEN
CLOSED
OPEN
CLOSED
OPEN
Safety output 2
OPEN
CLOSED
OPEN
CLOSED
OPEN
Status output
OPEN
OPEN
OPEN
CLOSED
OPEN