Closing slow-down 
point

Percentage adjustment of the total door travel, from the closing slow-down starting point.

 This function only appears when functions F11 and F30 are activated.

= 5% of the gate travel /... / 

15 

= 15% of gate travel (

default

) /... / 

30 

= 30% of gate travel

F48

Maneuver thrust 
activation

Greater pushing torque that activates during the operator's beginning opening and closing phases.

OFF

 (

default

) / 

ON

F49

Managing the serial 
connection

To enable the paired operating mode or the CRP (Came Remote Protocol).

OFF

 (

default

) / 

= Paired / 

= CRP

F50

Saving data

Saving users and saved settings in memory roll.

 This function only appears if a memory roll has been fi tted into the control board.

OFF

 (

default

) / 

ON

F51

Uploading date

Uploading data saved in memory roll.

 This function only appears if a memory roll has been fi tted into the control board.

OFF

 (

default

) / 

ON

F52

Transferring 
parameters in paired 
mode

Uploading settings from Master to Slave.

 This appears only if function F49 is set to Paired.

OFF

 (

default

) / 

ON

F54

Opening

direction

For setting the gate opening direction.

0

 = Opening left (

default

) / 

1

 = Opening right

F56

Peripheral number

To set the peripheral number from 1 to 255 for each control board when a system is fi tted with several 
operators and features the CRP (Came Remote Protocol) connection system.

1 ----> 255

F63

COM speed

For setting the communication speed used in the CRP (Came Remote Protocol) connection system.

0

 = 1200 Baud / 

1

 = 2400 Baud / 

2

 = 4800 Baud / 

3

 = 9600 Baud / 

4

 = 14400 Baud / 

5

 = 19200 Baud 

6

 = 38400 Baud (

default

) / 

7

 = 57600 Baud / 

8

 = 115200 Baud

F65

Wireless input 
RIO-EDGE [T1]

RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and 
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing, 
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.

 This function only appears if the RIOCN8WS card is plugged into the control board.

OFF (default) / P0 

= P0

 / P7 

= P7

 / P8 

= P8

F66

Wireless input 
RIO-EDGE [T2]

RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and 
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing, 
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.

 This function only appears if the RIOCN8WS card is plugged into the control board.

OFF (default) / P0 

= P0

 / P7 

= P7

 / P8 

= P8

F67

Wireless input 
RIO-CELL [T1]

RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = 
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.

 This function only appears if the RIOCN8WS card is plugged into the control board.

 The P3 function appears only if the F19 function is activated.

OFF (default) / P1 

= P1

 / P2 

= P2

 / P3 

= P3 / 

P4

 = P4

F68

Wireless input 
RIO-CELL [T2]

RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = 
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.

 This function only appears if the RIOCN8WS card is plugged into the control board.

 The P3 function appears only if the F19 function is activated.

OFF (default) / P1 

= P1

 / P2 

= P2

 / P3 

= P3 / 

P4

 = P4

F71

Partial opening time

After an opening command from the button connected to 2-3P, the gate opens for an adjustable time of 
between fi ve seconds and 40 seconds.

 

This function only appears if function F11 is deactivated.

= 5 Seconds (

default

) /... / 

40 

= 40 Seconds

Содержание BX708AGS

Страница 1: ...Sliding gate operator BX series BX704AGS 708AGS BX708RGS INSTALLATION MANUAL EN English FA00945 EN...

Страница 2: ...2 3 1 2 3 1...

Страница 3: ...well fastened to the ground entirely above the surface and free of any impediments to the gate s movement The rails of the upper guide must not cause any friction Make sure that opening and closing li...

Страница 4: ...use this device in any way except as specified in this manual INTENDED USE Model BX704AGS BX708AGS BX708RGS Standard reference length of the sliding part m 4 Maximum weight of the sliding part kg 400...

Страница 5: ...Cycles hour no 17 Consecutive cycles no 6 The cycles calculation refers to a gate that has a standard reference length see the intended use that are professionally installed free of any mechanical iss...

Страница 6: ...ng light 7 Photocells 8 Posts 9 Mechanical gate stop 10 Sensitive safety edge 11 Junction pit DESCRIPTION OF PARTS 1 Cover 2 Front cover 3 Gear motor 4 Condenser 5 Mechanical limit switch 6 Anchoring...

Страница 7: ...PES AND MINIMUM THICKNESSES Connection cable length 20 m 20 30 m Input voltage for 230 V AC control board 1P N PE 3G x 1 5 mm 2 3G x 2 5 mm 2 Flashing light 2 x 0 5 mm 2 Command and control devices 2...

Страница 8: ...surface Wait at least 24 hrs for the concrete to solidify Fit the bolts into the anchoring plate and tighten them using the nuts Remove the pre shaped clamps using a screw driver or pliers Place the p...

Страница 9: ...AME S p A Translated original instructions Remove the foundation frame and fill the hole with earth around the concrete block Remove the nuts from the bolts Fit the electric cables into the tubes so t...

Страница 10: ...must pass under the gearmotor casing and must not touch any parts that may overheat during use such as the motor or the transformer and so on Lift the gearmotor by 5 to 10 mm from the plate by adjusti...

Страница 11: ...zontal adjustment This prevents the gate s weight from bearing down on the operator FASTENING THE RACK If the rack is already set up the next step should be to adjust the rack and pinion coupling dist...

Страница 12: ...he plate using the supplied hardware Spring For closing close the gate t the closing limit switch tab into the rack until the micro switch is activated spring and fasten it using the grub screws ESTAB...

Страница 13: ...es DESCRIPTION OF PARTS 1 Power supply terminals 2 Gear motor terminals 3 Transformer terminals 4 Control board fuse 5 Terminals for control and safety devices 6 Fuse accessories 7 Terminals for the R...

Страница 14: ...e law Before connecting all the wires set up the cables by using cable glands on the control board brace as shown in the figure The electrical cables must not touch any heated parts such as the motor...

Страница 15: ...es power supply output 24 V AC max 20 W To change the motor torque plug the faston terminal as shown into one of the four positions from 1 min to 4 max 120 230 V AC 50 60 Hz POWER SUPPLY Flashing ligh...

Страница 16: ...e g the AF R800 you MUST CUT OFF THE MAIN POWER SUPPLY and remove any batteries PARTIAL OPENING function from control device NO contact OPEN CLOSE INVERT step step function from control device NO con...

Страница 17: ...g opening the contact triggers the inversion of movement until the gate is completely closed C3 partial stop Stopping of the gate if it is moving with consequent automatic closing if the automatic clo...

Страница 18: ...d WARNING For the system to work properly before fitting the control board you MUST CUT OFF THE POWER MAINS and remove any emergency batteries Serial RS485 connection via CRP Came Remote Protocol or f...

Страница 19: ...closing by sensitive safety edges with clean contact C8 reclosing during opening by sensitive safety edges with clean contact r7 reopening during closing for sensitive safety edges 8K2 resistive inpu...

Страница 20: ...hing light default 1 Cycle F19 Automatic Closing Time The automatic closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds The automatic closing...

Страница 21: ...available P0 stop gate and exclude any automatic closing to resume movement use the control device P7 reopening during closing P8 reclosing during opening For programming see the instructions that com...

Страница 22: ...f swing see the CALIBRATING SWING paragraph This function only appears if function F11 is activated If the operator is not calibrated it excludes all commands OFF default ON A 4 Resetting parameters C...

Страница 23: ...an opening maneuver until it reaches a final stop MANAGING USERS When adding and deleting users the flashing numbers appearing are those numbers that are available and usable to assign to a new user m...

Страница 24: ...9 130 131 132 133 134 135 136 137 138 139 140 141 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53...

Страница 25: ...2 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 20...

Страница 26: ...ror messages appear on the display Memory roll Memory roll SAVING AND UPLOADING ALL DATA USERS AND CONFIGURATION WITH THE MEMORY ROLL Procedure for memorizing all of the system s user and configuratio...

Страница 27: ...el calibration The programming keys on the SLAVE control panel are disabled Operating modes Either STEP STEP or ONLY OPEN command Both leaves open PARTIAL PEDESTRIAN OPENING command Only the MASTER op...

Страница 28: ...lla Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Manual FA00945 EN 01 2018 CAME S p A Translated original instructions The contents of this manual may change at any...

Отзывы: