CONTROL BOARD

 

Caution! Before doing any work on the control board, cut off the mains power supply, and disconnect any batteries. 

The functions available on the input and output contacts, the time adjustments and user management are all set and viewable on the segmented graphic 
display.

The operator is designed to be fitted on the left. If installing on the right, invert the gearmotor's U-V and the limit-switches FA-FC cables.

DESCRIPTION OF PARTS

1.  Power supply terminals
2.  Gear motor terminals
3. Transformer 

terminals

4. Control-board 

fuse

5.  Terminals for control and safety devices
6. Fuse 

accessories

7.  Terminals for the RGP1 module
8. Encoder 

terminals

9.  Keypad selector terminal
10. Terminals for limit-switch micro-switches
11. Antenna terminal

12. AF card slot
13. Terminals for transponder selector
14. Terminals for paired of CRP connection
15. Connector for the R700/R800/R900 card
16. Connector for the RIO-CONN card
17. RSE card slot
18. Programming buttons
19. Memory roll card slot
20. Display
21. Power supply on warning LED
22. Line fuse

Fuses

ZBX7N

 - Line

5 A-F (230 V AC)

8 A-F (120 V AC)

 - Card

630 mA-F 

 - Accessories

1 A-F

Содержание BX708AGS

Страница 1: ...Sliding gate operator BX series BX704AGS 708AGS BX708RGS INSTALLATION MANUAL EN English FA00945 EN...

Страница 2: ...2 3 1 2 3 1...

Страница 3: ...well fastened to the ground entirely above the surface and free of any impediments to the gate s movement The rails of the upper guide must not cause any friction Make sure that opening and closing li...

Страница 4: ...use this device in any way except as specified in this manual INTENDED USE Model BX704AGS BX708AGS BX708RGS Standard reference length of the sliding part m 4 Maximum weight of the sliding part kg 400...

Страница 5: ...Cycles hour no 17 Consecutive cycles no 6 The cycles calculation refers to a gate that has a standard reference length see the intended use that are professionally installed free of any mechanical iss...

Страница 6: ...ng light 7 Photocells 8 Posts 9 Mechanical gate stop 10 Sensitive safety edge 11 Junction pit DESCRIPTION OF PARTS 1 Cover 2 Front cover 3 Gear motor 4 Condenser 5 Mechanical limit switch 6 Anchoring...

Страница 7: ...PES AND MINIMUM THICKNESSES Connection cable length 20 m 20 30 m Input voltage for 230 V AC control board 1P N PE 3G x 1 5 mm 2 3G x 2 5 mm 2 Flashing light 2 x 0 5 mm 2 Command and control devices 2...

Страница 8: ...surface Wait at least 24 hrs for the concrete to solidify Fit the bolts into the anchoring plate and tighten them using the nuts Remove the pre shaped clamps using a screw driver or pliers Place the p...

Страница 9: ...AME S p A Translated original instructions Remove the foundation frame and fill the hole with earth around the concrete block Remove the nuts from the bolts Fit the electric cables into the tubes so t...

Страница 10: ...must pass under the gearmotor casing and must not touch any parts that may overheat during use such as the motor or the transformer and so on Lift the gearmotor by 5 to 10 mm from the plate by adjusti...

Страница 11: ...zontal adjustment This prevents the gate s weight from bearing down on the operator FASTENING THE RACK If the rack is already set up the next step should be to adjust the rack and pinion coupling dist...

Страница 12: ...he plate using the supplied hardware Spring For closing close the gate t the closing limit switch tab into the rack until the micro switch is activated spring and fasten it using the grub screws ESTAB...

Страница 13: ...es DESCRIPTION OF PARTS 1 Power supply terminals 2 Gear motor terminals 3 Transformer terminals 4 Control board fuse 5 Terminals for control and safety devices 6 Fuse accessories 7 Terminals for the R...

Страница 14: ...e law Before connecting all the wires set up the cables by using cable glands on the control board brace as shown in the figure The electrical cables must not touch any heated parts such as the motor...

Страница 15: ...es power supply output 24 V AC max 20 W To change the motor torque plug the faston terminal as shown into one of the four positions from 1 min to 4 max 120 230 V AC 50 60 Hz POWER SUPPLY Flashing ligh...

Страница 16: ...e g the AF R800 you MUST CUT OFF THE MAIN POWER SUPPLY and remove any batteries PARTIAL OPENING function from control device NO contact OPEN CLOSE INVERT step step function from control device NO con...

Страница 17: ...g opening the contact triggers the inversion of movement until the gate is completely closed C3 partial stop Stopping of the gate if it is moving with consequent automatic closing if the automatic clo...

Страница 18: ...d WARNING For the system to work properly before fitting the control board you MUST CUT OFF THE POWER MAINS and remove any emergency batteries Serial RS485 connection via CRP Came Remote Protocol or f...

Страница 19: ...closing by sensitive safety edges with clean contact C8 reclosing during opening by sensitive safety edges with clean contact r7 reopening during closing for sensitive safety edges 8K2 resistive inpu...

Страница 20: ...hing light default 1 Cycle F19 Automatic Closing Time The automatic closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds The automatic closing...

Страница 21: ...available P0 stop gate and exclude any automatic closing to resume movement use the control device P7 reopening during closing P8 reclosing during opening For programming see the instructions that com...

Страница 22: ...f swing see the CALIBRATING SWING paragraph This function only appears if function F11 is activated If the operator is not calibrated it excludes all commands OFF default ON A 4 Resetting parameters C...

Страница 23: ...an opening maneuver until it reaches a final stop MANAGING USERS When adding and deleting users the flashing numbers appearing are those numbers that are available and usable to assign to a new user m...

Страница 24: ...9 130 131 132 133 134 135 136 137 138 139 140 141 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53...

Страница 25: ...2 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 20...

Страница 26: ...ror messages appear on the display Memory roll Memory roll SAVING AND UPLOADING ALL DATA USERS AND CONFIGURATION WITH THE MEMORY ROLL Procedure for memorizing all of the system s user and configuratio...

Страница 27: ...el calibration The programming keys on the SLAVE control panel are disabled Operating modes Either STEP STEP or ONLY OPEN command Both leaves open PARTIAL PEDESTRIAN OPENING command Only the MASTER op...

Страница 28: ...lla Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Manual FA00945 EN 01 2018 CAME S p A Translated original instructions The contents of this manual may change at any...

Отзывы: