Foreword

• This product should only be used for the purpose for which it was explicitly 
designed. Any other use is considered dangerous. CAME Cancelli Automatici 
S.p.A. is not liable for any damage resulting from improper, wrongful or un-
reasonable use • Keep these warnings with the installation and use manuals 
issued with the automation system.

Before installing

(preliminary check: in case of a negative outcome, do not proceed until you 
have complied with the safety requirements)

• Check that the part you intend to automate is in good mechanical condition, 
balanced and aligned, and that it opens and closes properly. Make sure that 
proper mechanical stops are already in place • If the operator will be installed 
at a height of less than 2.5 m from the ground or other access level, check 
whether you will need any protections and/or warnings • Any leaves fi tted 
with pedestrian entrances onto which you will install an operator must have a 
blocking mechanism when the leaf is in motion • Make sure that the opening 
of the automated leaf is not an entrapment hazard as regards any surrounding 
fi xed parts • Do not mount the operator upside down or onto any elements that 
may fold under its weight. If needed, add suitable reinforcements at the points 
where it is secured • Do not install onto leaves not on level ground • Check 
that any lawn watering devices will not wet the operator from the bottom up.

Installation

• Carefully section off  the entire site to prevent unauthorised access, espe-
cially by minors and children • Be careful when handling operators that weigh 
more than 20 kg. In case, procure the tools required for safe gate movement 
• All opening commands (buttons, key selectors, magnetic readers etc.) must 
be installed at least 1.85 m from the perimeter of the area of turnstile move-
ment, or where they cannot be reached from outside through the turnstile. In 
addition, direct controls (button, touch sensitive keys, etc.) must be installed 
at a height of at least 1.5 m and must not be accessible to the public • All 
‘hold-to-run’ commands must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, apply a permanent 
label that shows the position of the release mechanism • Before delivering to 
the user, check that the system is EN 12453 (impact test) standard compliant. 
Make sure that the operator has been properly adjusted and that the safety 
and protection devices as well as the manual release are working properly • 
Where necessary and in plain sight, apply the Warning Signs (e.g. gate plate)

Special instructions and advice for users

• Keep the gate’s area of operation clean and clear of any obstacles. Check 
that there is no vegetation in the area of operation of the photocells and that 
there are no obstacles in the area of operation of the operator • Do not allow 
children to play with the fi xed command devices, or in the gate’s area of op-
eration. Keep any remote control devices (i.e. transmitters) or any control de-
vices away from children as well, to prevent the operator from being activated 
accidentally •The operator is not designed to be used by persons (including 
children) whose physical, sensorial or mental capacities are limited, or who are 
lacking in experience or knowledge, unless said persons can be supervised 
or given instructions regarding using the operator by a person responsible for 
their safety • Frequently check the system, to see whether any anomalies or 
signs of wear and tear appear on the moving parts, on the component parts, on 
the securing points, on the cables and any accessible connections. Keep any 
joints (i.e. hinges) lubricated and clean, and do the same where friction may 
occur (i.e. slide rails) • Perform functional tests on photocells and sensitive 
edges every six months. To check that the photocells work, pass an object in 
front of them during closing. If the operator reverses the direction of movement 
or comes to a halt, the photocells work correctly. This is the only maintenance 
operation that must be carried out while the operator is live. Ensure that the 
glass on the photocells is kept clean (use a cloth slightly moistened with wa-
ter; do not use solvents or any other chemicals as these could damage the 
devices) • If the system requires repairs or modifi cations, release the opera-
tor and do not use it until safety conditions have been restored • Cut off  the 
power supply before releasing the operator for manual openings and before 
any other operation, to prevent dangerous situations. Read the instructions • 
If the power cable is damaged, it must be replaced by the manufacturer or 

the technical assistance service or by a person with a similar qualifi cation 
so as to prevent any risks • It is STRICTLY FORBIDDEN for users to perform 
OPERATIONS THEY ARE NOT EXPLICITLY REQUIRED AND ASKED to do in the 
manuals. For repairs, adjustments and extraordinary maintenance, CONTACT 
THE SPECIALIST TECHNICAL SERVICE CENTRE • On the periodic maintenance 
log, note down the checks you have done. 

Special instructions and advice for all

• Avoid working near the hinges or moving mechanical parts • Stay clear 
of the gate’s area of operation when in motion • Do not resist the direction 
of movement of the gate; this may present a safety hazard • At all times be 
extremely careful about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using a selector or com-
mand in ‘hold-to-run’ mode, keep checking that there are no people in the 
area of operation of the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut the power when 
cleaning or performing maintenance. 

Danger of hand crushing

Danger - live parts

No transit during the manoeuvre

CAUTION!

important personal safety instructions:

READ CAREFULLY!

Содержание BX-324

Страница 1: ...119BV10IT OPERATOR FOR SLIDING GATES Installation manual BX 324 BX 324V English EN ...

Страница 2: ...vegetation in the area of operation of the photocells and that there are no obstacles in the area of operation of the operator Do not allow children to play with the fixed command devices or in the gate s area of op eration Keep any remote control devices i e transmitters or any control de vices away from children as well to prevent the operator from being activated accidentally The operator is not...

Страница 3: ... and condominium use Any installation and operation that differs from what is set out in this manual is prohibited Limits of use Type BX 324 BX 324V Max leaf length m 8 5 Max leaf weight kg 300 REGULATORY REFERENCES Came Cancelli Automatici is a company with an ISO 9001 certified company quality management system and an ISO 14001 certified environmental management system The product in question co...

Страница 4: ... may hinder gate movement Check that the upper guide blocks do not create friction Make sure there is one opening and one closing mechanical stop Make sure that the mounting point for the gearmotor is in an area protected from impacts and that the anchoring surface is solid Provide a suitable single pole disconnection device with a maximum of 3 mm between the contacts to disconnect the power suppl...

Страница 5: ...max 10 m N B If the cables differ in length compared to what is shown in the table the cable cross section is determined according to the actual current draw of the devices connected and according to the provisions of the IEC EN 60204 1 standard For connections that require several sequential loads the sizes given on the table must be re evaluated based on actual power draw and distances When conn...

Страница 6: ...ed tubes necessary for the connections from the inspection chamber In order to connect the gearmotor a Ø 60 mm corrugated tube is advisable Ø 25 mm pipes are recommended for accessories on the other hand N B the number of tubes depends on the type of system installed and any accessories Installing the mounting plate Prepare a counterframe that is larger than the mounting plate and place it in the ...

Страница 7: ...ent The plate must be perfectly level with the screw threads completely on the surface Wait at least 24 hours for it to harden Remove the counterframe and fill the hole around the block of cement with earth Remove the nuts and washers from the screws Insert the electric cables in the tube until they protrude approximately 400 mm Securing the gearmotor Remove the gearmotor cover by unscrewing the s...

Страница 8: ... the rack on top of the gearmotor pinion Lift the gearmotor 5 to 10 mm up from the plate using the threaded steel feet for any subsequent adjustments between the pinion and the rack Weld or secure the rack to the gate along its entire length To assemble the rack modules use a piece of scrap and place it under the join point securing it using two terminals N B if the rack is already present proceed...

Страница 9: ...t and the slots horizontal adjustment This prevents the weight of the gate bearing upon the operator When adjustment is complete secure the gearmotor to the plate using the washers and nuts Feet Slot Rack Pinion Rack Pinion Horizontal adjustment Vertical adjustment Determining the end run points Position the end run fins on the rack and secure them using the 3 mm hex key Their position limits the ...

Страница 10: ... code memorisation buttons 6 ACT trimmer adjusting the automatic closing time 7 Function select DIP 8 Connector for AF card 9 Indicator LED 10 Accessory encoder and end run connection terminal block 11 Emergency batteries connection board terminal block FUSE TABLE Line fuses 1 6 A F Panel fuse 315 mA F Accessory fuse 1 6 A F General description The card has an amperometric device that continuously...

Страница 11: ... on the control panel Stop button NC contact Stops the gate with the exclusion of automatic closing To resume movement press the control button or other control device NB if not used short 1 and 2 OPEN STOP CLOSE STOP sequential function OPEN CLOSE step by step from the control device N O contact See dip switch 2 function selection Control devices Flashing light Contact rated for 24 V AC DC 25 W m...

Страница 12: ...78 standard While the operator is closing the opening of the contact causes the reversal of the direction of movement until completely open Safety devices Photocells DIR Photocells DELTA S Photocells DELTA 1 ON AUTOMATIC CLOSING function activated 2 ON OPEN STOP CLOSE STOP function from the transmitter and or the button 2 7 activated 2 OFF OPEN CLOSE function from the transmitter and or the button...

Страница 13: ...cards only position the jumper as shown according to the series of transmitters used DISCONNECT POWER AND REMOVE THE BATTERIES IF PRESENT Insert the AF card on the control board N B the control board only recognises the AF card when the operator is powered again Hold down the CH1 key on the control board the LED indicator flashes Press a key on the transmitter to send the code The LED will remain ...

Страница 14: ...r The operation must be carried out while the power is off MAINTENANCE Before any maintenance disconnect power to prevent any possible dangerous situations that can be caused by accidental movement of the operator Lubricate the rotation points with grease whenever abnormal vibrations or squeaking occurs as shown below Date Notes Signature Periodic maintenance Periodic maintenance log to be complet...

Страница 15: ...ERLY DECLARATION OF CONFORMITY Declaration Came Cancelli Automatici S p A declares that this device complies with the essential requirements and other relevant provisions established in Directives 2006 42 CE and 2004 108 CE Reference code for requesting a true copy DDI B IT B001 TROUBLESHOOTING MALFUNCTIONS POSSIBLE CAUSES CHECKS AND REMEDIES The gate does not open or close No power The gearmotor ...

Отзывы: