ENGLISH

 

The unit does not require specifi c maintenance. Only as a precautionary measure and in case of intensive use, it is opportune 

to periodically (every six months) check that the electric cables are in good condition and that the bolts and nuts are tight, and oil the 
contact areas between the fi xed and mobile sliding pieces.

All checks must be recorded (in a dedicated record-book).

Maintenance

 

In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in compliance 

with the UNI EN ISO 14001 standard to ensure environmental protection.

Please continue our eff orts to protect the environment—which CAME considers one of the cardinal elements in the development of its 
operational and market strategies—simply by observing brief recommendations as regards disposal:

 

DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste products 

and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.

PLEASE DISPOSE OF PROPERLY!

 

PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical wires, 

etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c recyclable material collection 
bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, etc.), however, may contain polluting 
substances. They should therefore be removed and given to qualifi ed service companies for proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.

PLEASE DISPOSE OF PROPERLY!

Demolition and disposal

Periodic maintenance

Problem solving

THE GATE DOES NOT MOVE:

- check the 120V or 230V AC power on the terminals L-N;
- check the fuses;
- check the 24 V power on terminals 10-11;
- check the connection of the stop button; if not used, set the dip 10 to ON;
- check the safety device connection (partial stop); if unused, set dip switch 8 to ON
- check that the small access panel for blocking/release is closed.

THE GATE REMAINS IN THE OPEN POSITION: 

- automatic closure disabled, see dip no.1;
- check all the command devices are working correctly; 
- ensure that nothing is obstructing the safety devices;
- make sure all N.C. contacts are set to ON if not used. 

www.metalines.com

[email protected]

Содержание BK 800

Страница 1: ...INSTALLATION MANUAL BK 800 1200 1800 2200 BKE 1200 1800 2200 AUTOMATION FOR SLIDING GATES English EN 119BS04EN www metalines com sales metalines com...

Страница 2: ...missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant Make sure that the o...

Страница 3: ...www metalines com sales metalines com...

Страница 4: ...mple 1 2 chain 009 CGIU 1 2 chain joint Important Check that the safety equipment and accessories are CAME originals this is a guarantee that also makes the system easy to set up and upkeep Descriptio...

Страница 5: ...tor 2 Board cover support 3 End stop flaps 4 ZBK ZBKE basic control board 5 Electric board front cover 6 Release door 7 Base plate 8 Securing screws 9 Plates for securing screws 10 Nuts ACCESSORIES 1...

Страница 6: ...al conductive parts Set up suitable tubing and trenching to allow for electrical cables to pass making sure they are free from any potential mechanical damage Only expert qualified personnel must carr...

Страница 7: ...embedded in the concrete in the positions indicated the drive unit is then attached to this bots The anchor plate must be perfectly level and absolutly clean the bolts threads must be completly expos...

Страница 8: ...ow Release the gearmotor position the rack on the pinion of the gearmotor and slide the gate manually in order to attach the rack along its entire length when the rack is attached to the gate adjust t...

Страница 9: ...whose positions determine the limits of gate travel on the rack Note do not allow the gate to strike the mechanical stops in the open or closed positions Manual release of the gearmotor To open the ac...

Страница 10: ...y closes it Warning After the gate s direction is inverted three consecutive times the gate remains opened excluding the automatic closing function use the remote control or push button to close the g...

Страница 11: ...nection Connection for the limit switch unit BK series ORANGE RED WHITE Connection for gear motor limit switch or encoder RED Invert the phases of the gear motor U V On the BK series invert wires FA F...

Страница 12: ...t gate leaf is open and turns off when the gate is closed Courtesy lamp Contact output 230V 60 V max Auxiliary connection for suitably positioned external lamp to increase lighting of the steering are...

Страница 13: ...the direction of movement until the gate leaf is fully open N C contact for partial stop Input for safety devi ces such as photocells sensitive safety edges and other devices compliant with EN 12978...

Страница 14: ...sed by acting on their corresponding DIPs see selecting functions Electrical connection for the check of the operating state of the photocells A C T Trimmer Automatic Closing Time This adjusts the gat...

Страница 15: ...losing they trigger an inversion of direction movement until full opening is achieved insert the safety device into terminal 2 C1 if not used set dip switch to ON 8 OFF 9 OFF Re closing during opening...

Страница 16: ...ate leaf press the CLOSE button the led indicator keeps ashing as long as button is kept pressed 3 Manually open the gate leaf press the OPEN button the led code indi cator keeps ashing as long as the...

Страница 17: ...es while on the control board of the 2nd motor position dip switch 11 to the ON position to place it into a slave state N B Make sure that the radio frequency board is inserted only into the Master bo...

Страница 18: ...ying the transmitter memorizing the code on the command board Radio board AF Motherboard 2 The AF board must ALWAYS be inserted into the coupling ref point 5 page 8 when the power is off because the m...

Страница 19: ...158 ATOMO AT01 AT02 AT04 CAME CAME CAME CAME CAME CAME CAME CAME CAME CAME Pag 17 17 Manual code 119BS04EN 119BS04EN ver 6 6 04 2013 CAME cancelli automatici s p a The data and information reported in...

Страница 20: ...sequence described above CH2 Channel for direct commands to an auxiliary device or for the control of two paired motors con nected to B1 B2 Memorizing the code on the command board CH1 Channel for di...

Страница 21: ...Prior to disposal it is always advisable to check speci c regulations in force in the place of installation PLEASE DISPOSE OF PROPERLY PRODUCT DISPOSAL Our products are made up of various types of ma...

Страница 22: ...empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da empresa de produtos e assist...

Отзывы: