![CAME 801QA-0080 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/came/801qa-0080/801qa-0080_installation-manual_486842035.webp)
P
age
35
- Manual
FA01412-EN
- 01/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
Confi guration>
Command inputs
Hold-to-run
Deactivated (Default)
On
Electric lock
Associate the electric lock release with a command.
Confi guration>
Functions
Electric lock
Deactivated (Default)
Open
Close
Opening and closing
Continuous when opening and closing
Closing thrust
When the leaves reach the closing limit-switch, the operator thrusts them towards the strike plate for a second.
Confi guration>
Functions
Closing thrust
Deactivated (Default)
Minimum
Medium
Maximum
Thrust
Before every opening or closing manoeuvre, the leaves thrust inwards to release the electric lock.
The command operates during opening or closing, depending on where the electric lock is active (see function
[F17 electric lock]).
Confi guration>
Functions
Thrust
Deactivated (Default)
On
Removing obstacles
If an obstacle is detected via the AST control on the board or by a safety edge input, the [Remove obstruction] function inverts
the gate leaf far enough to free the obstruction, then it stops.
Confi guration>
Functions
Removing obstacles
Deactivated (Default)
On
B1-B2 output
Confi gure the contact.
Confi guration>
Functions
B1-B2 output
Bistable
Monostable: on from 1 to 180 seconds (Default 1)