background image

!,%

3

 43 " "

!,%

3

 43 " "

./

.#

#

&53)"),%M!

48

48

  48 #

.#

 # #

0

(Delta)

(DIR)

2
3

45

2
3

45

6

ENGLISH

P.

 

99

 - 

M

an

u

al

 c

od

e: 

31

9

U

3

6

31

9

U

3

6

 ve

r.

 

1.

0

1.

0

 05

/2

0

11

 © C

A

M

E c

an

ce

lli auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on

 in

 th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny tim

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n th

e p

art of C

am

e C

an

ce

lli A

uto

m

ati

ci

 S

.p.a. to n

otify s

ai

d c

h

an

g

es.

With each opening and c
losing command, the card checks the effi

  ciency of the safety devices 

(i.e. photocells). Any anomalies
 in the photocell is notifi ed by the fl ashing 
LED (PROG) on the control panel, and cancels any other command from the transmitter or button.
Electrical connection to work the photocells safety test:
- the transmitter and receiver, must connected  as shown in the diagram:
Set Dip-switch 3 (Four-way Dip-switch) to ON to activate the test.
IMPORTANT: 
When you activate the safety test, CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2-C3, 2-C1 and, if the contacts are 
unused, exclude them via Dip-switch 8 and 10.

6.1 Electrical connection for photocells functionalities test

Stop button (

(N.C.) contact.

- Door stopping button that excludes the automatic closing.To resume movement 
press the command button or trasmitter key.
If unused set DIP switch n.9 to ON.

Key-switch selector and/or opening button (

  N.O. contact

Door opening and closing commands, by pressing the button 
or turning the selector key, 

 

the door inverts its movement 

or stops depending on what is selected on the Dip-switches 
(see selecting functions, Dip-switches 2 and 3). Jumper OFF 
(p. 4 point 20) .

Ket switch selector and/or opening button (

N.O. contact

- Door opening command.

Command devices

Key switch selector and/or opening button (

N.O. contact

- Door 

closing command.

 Jumper ON (p. 4 point 20).

Содержание 319U36EN

Страница 1: ...English EN INSTALLATION MANUAL ZL19NA Z CONTROL PANELS CONTROL PANEL FOR 24V GEARMOTORS 836EN...

Страница 2: ...30 V AC at 50 60 Hz frequency the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features...

Страница 3: ...ntainer protection rating IP54 working temperature 20 55 C You can also connect the open door signal lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outages...

Страница 4: ...ed with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Pr...

Страница 5: ...1 Secure the base of the panel in a safe area yes max 6 mm Head with to 2 Perforate where shown and insert the gable gland with the corrugated tubes for the electrical cables to go through Careful no...

Страница 6: ...automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections...

Страница 7: ...ssories power source Lighting and warning devices Flashing light for open doorContact rated for 24 V 3 W Max Signals the position of the open door it turns off when the door is closed Flashing light c...

Страница 8: ...ls and other devices that comply with EN 12978 regulations Door stopping if it is moving with subsequent automatic closing If unused set DIP switch n 8 to ON Safety devices C1 N C contact di riapertur...

Страница 9: ...to activate the test IMPORTANT When you activate the safety test CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10...

Страница 10: ...ommand it prevents any movement if the safety devices e g photocells detect an obstacle 6 ON Maintained action Door opens and closes only if button is kept pressed 7 ON Ramming function activated At e...

Страница 11: ...ADJ SENS End adjustement of amperometric sensor during travel min max AMP SENS Adusts the amperometric sensitivity which controls the force developed by the motor during movement if the force exceeds...

Страница 12: ...nges Adjusting the microswitch Swing the door until it is about 500 mm from its closed position Turn the outer cam until the micro switch is inserted and lock it using the screw Micro switch Outer slo...

Страница 13: ...radio command Connect antenna cable to the apposite terminals Antenna Possible second channel output of the radio receiver N O contact Contact rated for 1 A 24 V DC Jumper p 4 point 15 in pos B Adjust...

Страница 14: ...teries and snap in the radio frequency card into the electronic card N B The electronic card recognises the radio frequency card only when it is powered up Only for the AF43S AF43SM radi frequency car...

Страница 15: ...132 T134 T138 T152 T154 T158 ATOMO AT01 AT02 AT04 TWIN TWIN 2 TWIN 4 ENGLISH P 15 15 Manual code 319U36 319U36 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manua...

Страница 16: ...ashes ON and OFF 2 Press the button on the transmitter you want memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Страница 17: ...solid waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially a...

Страница 18: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Отзывы: