F1 Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
NC input - Barrier stops while excluding any automatic closing; to resume movement, use the control device. The safety device is inserted into
[1-2].
F2 Input [2-CX]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C5 = immediate closing, C9 = immediate closing with obstruction wait during closing.
F3 Input [2-CY]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C5 = immediate closing, C9 = immediate closing with obstruction wait during closing.
F5 Safety test
0 = Deactivated (
default
) / 1 = CX / 2 = CY / 3 = CX+CY
After every opening or closing command, the board will check whether the photocells are working properly.
IMPORTANT! IMPORTANT! Start programming by first performing the following: A1 BOOM-TYPE SETTING, A2
MOTOR TEST, F1 TOTAL STOP and A3 CALIBRATING BOOM TRAVEL.
Functions menu
F 1
Total stop function (1-2)
F 2
Function associated to input CX
F 3
Function associated to input CY
F 5
Safety test function
F 6
Maintained action function
F 9
Obstruction detection with motor idle function
F 10
Function associated the open-barrier signal output
F11 Exclude
Encoder
F 14
Sensor type selection function
F 15
Intermittent luminous cord function
F 18
Additional light function
F 19
Automatic closing time
F 21
Preflashing time
F 22
Working time
F 25
Courtesy light time
F 28
Adjusting opening speed
F 29
Adjusting closing speed
F 30
Adjusting opening slow-down speed
F 31
Adjusting closing slow-down speed
F 33
Adjusting calibration speed
F 34
Sensitivity during travel
F 35
Sensitivity during slow-downs
F 37
Adjusting the opening slow-down starting point
F 38
Adjusting the closing slow-down starting point
F 49
Manage serial connection
F 50
Save data in memory roll
F 51
Reading memory roll data
F 52
Copying parameters from Master to Slave
F 56
Number of the peripheral
F 60
Sleep Mode function
F 61
Pre-flashing function
F 63
Changing COM speed
U 1
Enter new user with an associated command
U 2
Delete single user
U 3
Deleting all users
A 1
Boom-type setting
A 2
Motor test
A 3
Travel calibration
A 4
Resetting parameters
A 5
Counting maneuvers
H 1
Software version
Functions map
Содержание 001G4040EZT
Страница 1: ...English EN Русский RU Italiano IT Français FR FA00583M04 BARRIERE AUTOMATICHE ...
Страница 33: ...English EN INSTALLATION MANUAL G4040EZT AUTOMATIC BARRIERS FA00583 EN ...
Страница 65: ...Français FR MANUEL D INSTALLATION G4040EZT BARRIÈRES AUTOMATIQUES FA00583 FR ...
Страница 97: ...Русский RU ИНСТРУКЦИЯ ПО МОНТАЖУ G4040EZT АВТОМАТИЧЕСКИЕ ДОРОЖНЫЕ ШЛАГБАУМЫ FA00583 RU ...