Configuring the system for winter control
Configuring the system for summer
Configuring for winter control
Configuring for summer control
Configuring for winter control
Configuring for summer control
Properties:
Properties:
Properties:
Properties:
PUMP
PUMP
ZONE 1 VALVE
ZONE 1 VALVE
BOILER
BOILER
ZONE 2 VALVE
ZONE 2 VALVE
FAN COIL
FAN COIL
ZONE 3 VALVE
ZONE 3 VALVE
TH/PLUS (Id: 70BD62C1)
TA/P1 (Id: 070013E15001)
TH/PLUS (Id: 70BD62C1)
TA/P1 (Id: 070013E15001)
First, you need to tell the system which outputs are connect-
ed to the heating devices you will use.
By pressing icons
you can scroll the list of outputs that
control valves, pumps, boilers, fan coils, and so on.
Check the box that corresponds to the outputs that control
the pump and boiler, depending on the type of system you
have.
By pressing icons you can scroll the list of thermal de-
vices selected to control the various thermal zones.
Check the box that corresponds to the output that controls
the valve present in the zone where the thermal device is
operating.
Each thermal device selected to control a specific zone needs
to also control a heating valve.
First, you need to tell the system which outputs are connect-
ed to the cooling devices you will use.
By pressing icons
you can scroll the list of outputs that
control valves, pumps, boilers, fan coils, and so on.
Check the boxes that correspond to the outputs that control
the pump and fan coil, depending on the type of system you
have.
By pressing icons you can scroll the list of thermal de-
vices selected to control the various thermal zones.
Check the box that corresponds to the output that controls
the valve present in the zone where the thermal device is
operating.
Each thermal device selected to control a specific zone needs
to also control a cooling valve.
Once the thermal devices are configured, the system is now
fully configured; to return to the start page, press icon
☞
Once the configuration procedures are finished, the system in goes into OFF mode.