Programming the door release code and relay with DNA.
Press and key in the
relay code you wish to programme (press key 1 to activate the door opening control in
the entry panel; press key 2 to activate relay 1 on the VLS/2 relay module; press key 3
to activate relay 2 on the VLS/2 relay module)
7
. Press once again and key in the
desired code (from 3 to 5 figures).
Once programming has been completed, by pressing the key plus the desired code
and
8
, it is possible to activate the door opening control and relay 1 or 2.
Exiting Programming.
Briefly press the PROG key on the power
supply: the PROG LEDs and the LEDs on the entry panels will
go out. NOTE. If no action is performed, the procedure will end
automatically after 30 minutes.
Entering Codes and Tags
Position the power supply's PROG RFID jumper at “+”
1
: the power supply's PROG
LED will flash slowly along with the message LEDs with the configuration in fig.
2
. If
the LEDs immediately go out it means there is a malfunction in the connections between
the power supply and entry panel. Check the connections and return to programming.
Badge.
Bring a badge/tag up to the reader of any entry panel that
has already been addressed
3
and, after the confirmation beep,
press the key (group) to which the code should be assigned
4
. If
the maximum permitted number is exceeded (5) for each group,
an error tone will be generated.
Codes.
Press , enter the access code (4-8 figures) followed by the key on the
keypad of any already addressed entry panel reader
5
and, after the confirmation beep,
enter the call code for the group and then press
6
(or press the group key). If
the maximum permitted number is exceeded (5) for each group, an error tone will be
generated.
Finally, reposition the PROG RFID jumper in the rest position
7
: the procedure is
NOT terminated automatically!