background image

Push Buttons

Keypads

Strikes

Magnetic Locks

Key Switches

Relays & Timers

Access Control

5502 Timberlea Blvd., 

Mississauga, ON Canada 

L4W 2T7

www.camdencontrols.com 

Toll Free: 1.877.226.3369

File: CX-ED2079 Designer 

        Installation Instructions.indd R6 

Revision: 01/06/2018  

Part No.: 40-82B187

CX-ED2079 ‘Universal’ Electric Strike

Page 3 of 3

Red

Black

Blue

Green

Black

Red

Blue

Green

Black

Red

Blue
Green

(+12V)

( - )

(+24V)

( - )

12V

24V

Varistor  

Varistor  

Power

Power

5. Connections

6. Operation

POWER  

12VDC

 

Red/Black:   +12V 

Blue/Green:   Ground

A varistor is provided to protect/prevent strike from spikes.  

Connect varistor between input wires.

Fail Safe

Changing

Fail Secure

(32mm)

(16mm)

1 ¼”

5⁄8”

(32mm)

1 ¼”

(104mm)

4 1⁄8”

(123mm)

4 7⁄8”

(16mm)

5⁄8”

(104mm)

4 1⁄8”

(123mm)

4 7⁄8”

(154mm)

6 1⁄8”

(173mm)

6 7⁄8”

(189mm)

7 ½”

(200mm)

7 7⁄8”

(85mm)

3 3⁄8”

(19mm)

¾”

(85mm)

3 3⁄8”

(19mm)

¾”

(85mm)

3 3⁄8”

(85mm)

3 3⁄8”

(32mm)

1 ¼”

(44mm)

1 ¾”

(57mm)

2 ¼”

(16mm)

5⁄8”

(36mm)

1 3⁄8”

(16mm)

5⁄8”

7. Faceplates

24VDC

 

Red:  

+24V 

Black/Blue:       - 

Green:  

Ground

How to modify fail-safe to fail-secure or vice versa.
(1). Loosen the screw as per the product diagram below.
(2). Rotate the set plate 180° and slide the plate until it is    

     properly seated.
(3). Tighten the screw.

Note: For UL 294 / UL 1034 compliance the door strikes 

are to be powered via a UL 294/ UL 603  class 2 power 

limited output from a control panel and or power supply.  

Furthermore, when powered by AC/DC the units shall use a 

UL regulated UL 294/ UL 603  power limited class 2 output 

rated 12/24V with AC on indicator.

ESP1B - ANSI Square

ESP3B - Hollow Metal Door

ESP4B - Wood Door

ESP2B - Ansi Round

INCLUDED IN PACKAGE

ADDITIONAL FACEPLATE

Отзывы: