CM-RQE70A PIR ‘REQUEST TO EXIT’ DETECTOR

INSTALLATION INSTRUCTIONS

Vin- C1 NO1 NC1 C2 NO2 NC2

Vin+ I1 I2 I3 GND T1 T2

12 - 24 V

DC

 

Power

+

-

Maglock

MOV

Door Contact Request to Exit

Push Button

Sounder

Control

Notes:

1. Relay is set to Safe Mode in  

  this application

2. Relay O/P2 is EMF protected.  

  If using O/P1a diode should be 

  place across the maglock 

     power connections.

Notes:

1. Relay is set to Safe Mode in 

  this application

2. Relay O/P2 is EMF protected.  

  If using O/P1a diode should be 

  place across the maglock 

     power connections.

Notes:

1. Relay is set to Safe Mode in  

  this application

2. Relay O/P2 is EMF protected.  

  If using O/P1a diode should be 

  place across the maglock 

     power connections.

MODE 1&2 WIRING DIAGRAM

Vin- C1 NO1 NC1 C2 NO2 NC2

Vin+ I1 I2 I3 GND T1 T2

12 - 24 V

DC

 

Power

+

-

Maglock

MOV

Door Contact Request to Exit

Push Button

MODE 3 WIRING DIAGRAM

1 2 3
4 5 6
7 8 9

Access

Control

Keypad/

Reader

Vin- C1 NO1 NC1 C2 NO2 NC2

Vin+ I1 I2 I3 GND T1 T2

12 - 24 V

DC

 

Power

+

-

Maglock

MOV

Door Contact Request to Exit

Push Button

MODE 4 WIRING DIAGRAM

REX Sensor

Keypad

Eye Beams

J2

J4

J2

J4

J2

J4

J2

1

2

3

4

5

6

7

J4

1

2

3

4

5

6

7

Description

Power +

Input 1

Input 2

Input 3

Ground

Tamper Switch 1

Tamper Switch 2

Description

Relay 1b - Normally Closed (NC2)

Relay 1b - Normally Open (NO2)

Relay 1b - Common (C2)

Relay 1a - Normally Closed (NC1)

Relay 1a - Normally Open (NO1)

Relay 1a - Common (C1)

Power -

EMF Spike

protected relay

Voltage:

 

  12 /24V DC operation

Current Draw:

     50mA (max)

Relays:

  

  (2) Form ‘C’ (DPDT)

Contact Rating:

    3A @ 30VDC

Programming: 

    On-board push buttons  

 

  and status LED

Modes:

 

  - (4) Factory Default 

 

  - (1) Fully Custom 

 

  -  Selectable Fail Safe/ 

Fail Secure

Coverage:

  

  - Max. 10’ W x 10’ H 

 

  -  Horizontal & vertical  

adjustment (mechanical)

 

  -  Sensor sensitivity/range  

(electronic)

Time Delay:

 

  Adjustable, 0.5, 1, 2.5,  

 

  5, 15, 30, 45 & 60  

 

 second

Sounder:

  

  On/Off, with adjustable  

 

 volume

Piezo Buzzer:

     92db.@ 10cm. 

Indicator: 

 

  Activation LED

Card or  

Keypad Input:

    (1) N/O

Door Position  

Switch Input:

     (1) N/O 

Request to  

Exit Input:

 

  (1) N/O 

Tamper Switch  

Contact Rating:

   50mA @ 12VDC

Temp Operating 

Range:

  

  32°F - 120°F (0 - 50°C)

Humidity Range:

  0 - 93% non-condensing

Dimensions:

 

  1 3/4”H x 7” W x 1 3/4” D   

 

  (43mm x 176mm x 43mm)

Weight:

  

  0.25 lbs. (0.12kg.)

Colors:

 

  White and black models

UL 294 Access Control Performance 
Levels

1)  

Access Controls, Destructive Attack 

Level I (No Attack)

2)  

Line Security -

 Level I (No Line  

 

Security)

3) 

Endurance -

 Level IV (100,000 cycles)

4)  

Standby Power - 

Level I (No Stand by 

Power)

Power is to be supplied by a compatible 

UL294 Listed control unit, or by a UL294 

Listed or UL603 Listed Class 2 low-voltage 

power limited power supply that is capable of 

4 hours of standby power, as described in the 

installation guide.
The products shall not be installed in the  

fail-secure mode unless permitted by the  

local authority having jurisdiction and shall 

not interfere with the operation of Listed 

panic hardware.

5. SPECIFICATIONS