CM-RQE70A   

PIR ‘REQUEST TO EXIT’ DETECTOR

INSTALLATION INSTRUCTIONS

Door Activation Devices 

1. GENERAL DESCRIPTION

Camden CM-RQE70A Request-to-Exit Sensor is a passive infrared (PIR) 
detector designed for interior use. This device is UL listed as an access 
control device under UL 294 Standard and is listed for Class I for UL 
Canada under ULC-S319 when it is connected to a UL approved access 
control system.

2. FEATURES

• Compact size, designed to mount on door frames

•  On-board programming buttons. No dip switches

•  (4) factory default operating modes, with the ability to customize mode 

attributes 

•  Makes installation easy and fast

•  Selectable Fail Safe/Fail Secure

•  (2) Form ‘C’ contacts

•  Momentary and latching relay modes

•  Secondary activation device input

•  Card/keypad input

•  Door position switch input

•  Request to exit input

•  Built-in sounder (adjustable)

•  Tamper switch

3. OPERATION

FIGURE 1 - COMPONENT LOCATIONS 

FIGURE 1 - MOUNTING LOCATIONS 

Self-Test 

When power is first applied to the CM-RQE70A, the sensor will beep 
once, then the unit performs a self-test to ensure its major functions are 
within acceptable operating parameters. The self-test checks the input 
voltage, switch operation and sensor function. If the sensor passes all 
tests, there is a single beep and normal operation begins. If the sensor 
fails any of the tests, the unit will provide a series of audible beeps 
indicating the failure. This is take approximately 30 seconds.

Post-Test Failure Beeps

If the sensor fails a test, the unit will perform one or more short beeps, 
followed by a long beep. This series of beeps is repeated continuously.

# of Short 
Beeps

Description

1

The IR sensor did not settle to an acceptable level 
during the test.

2

One of the 3 buttons, Mode, Parameter or Select is 
detected as being pressed.

3

The Source Voltage to the CM-RQE70A is outside 
of the range of 12 – 24V

4

The IR sensor is not changing over a large enough 
range of values to reach its settle point

Fail Safe vs Fail Secure: Field Selectable 

These terms are used to describe the normal operating state of the 
output relays. In Fail Safe Mode, the relays will be normally energized. 
The relays will de-energize when a person is in the field of view (normal 
operation) or when the power is removed due to an outage or other 
external reasons. In Fail Secure Mode, the relays remain de-energized 
normally. The relays will energize when a person is in the field of view 
(normal operation). The relays remain de-energized during a power 
outage, therefore, keeping the controlled device secure.

(2) #6 x 3/4" Screws
(2) 3/16" Wall Plugs
(2) MOV's

THIS PACKAGE INCLUDES

BP7175

MODE

PARAMETER

ADJUST

LED

LENS

LOCK

DOWN

SCREW

TAMPER

SWITCH

SOUNDER

OUTPUT

RELA

Y

J4

J2