Page 4 of 11
CM-550SK-V2 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
7.3 System Setting
Standby
Master Code
Menu
Setting
Remarks
Functions
Red Flash
Red
Red
Orange
*
Master Code #
30
0-15 #
Default 0
To Set Facility Code
31
0 #
This setting is not
affected by resetting
to factory default.
Wiegand Reader
1 #
Standalone for Single Door
33
0-2 #
This setting is not
affected by resetting
to factory default.
To set keypad
transmission format
0=26 bit weigand
1=4 bit burst
2=8 bit burst
34
1-3 #
Default 1
To set alarm time in minutes
35
0 #
Default 0
Normal mode
1 #
Lock out mode
2 #
Alarm mode
7.4 User Optional Setting
Standby
Master Code
Menu
Setting
Remarks
Functions
Red Flash
Red
Red
Orange
*
Master Code #
41
0 #
Buzzer is turned off, except while in programming mode
1 #
Default 1
Buzzer will sound during key presses
42
0 #
Disable keypad backlighting
1 #
Enable keypad backlighting
43
0 #
LED Light Disable while in stand-by
1 #
Default 1
LED flashes while in stand-by
Notes:
1. Master code must be 6-8 digits.
2. Anti-duress PIN must be 8 digits.
3. User PIN is 4-6 digits.
4. The user ID number is any number from 1-2000
5. Door open time is 0-99 second, 0=50mS.
6. While operating the keypad, pressing # means to confirm the input digits, in operation of a cycle adding or deleting PIN
code, pressing # means to end the cycle operation and back up the operation; pressing * means to exit the operation.
7. Keypad Wiegand modes are set at the factory to 26 bit. If the output format is changed through programming, the
changes are not affected by a reset to factory defaults.