CAMDEN CM-120wV2 Скачать руководство пользователя страница 6

 Installation Instructions 

 

 

 

 

 

 

2 = relay 2 
3 = both buzzer and relay 2 
 
To  program  how  the  “Door  forced  open  alarm” 
condition is annunciated: 
First,  enter  program  mode.  Then  enter  [*4],  then  6#, 
then the annunciation code, then *. 
 
For example, 

[*4] 6 # 3 * 

will configure the keypad to 

sound an alarm at both the buzzer and relay 2 if the 
door is forced open (without entering a valid code). 

NOTE  1:

  this  feature  requires  the  use  of  the  door 

contact input. 

NOTE  2:

  The  alarm  will  sound  continuously  until 

reset. To reset, enter valid code. 

 

[*5] Wiegand Control Functions 

 
0# Wiegand Protocol selection 
 

Default: 0 (Disabled) 
Use to control and select the wiegand protocol. 
0 = disabled 
1 = 26b raw 
2 = 26b raw plus facility code 
 
To enable and select the wiegand output function: 
First,  enter  program  mode.  Then  enter  [*5],  then  0#, 
then the protocol code, then *. 
 
For example, 

[*5] 0 # 1 *

 will configure the keypad to 

output 26 bit wiegand. 
 

NOTE  1

:  If  wiegand  output  is  chosen,  then  both 

relays,  and  RF  outputs  are  automatically  disabled. 
The REX input is also disabled. 
See Diagram 2, Page 10 for wiring instruction. 

NOTE  2

:  If  protocol  2  is  chosen,  then  the  2-digit 

facility code must be selected in the next step. 
 

1# Wiegand Facility Code 
 

Default: 34 (Camden) (0 – 255 allowed) 
Use  to  select  the  facility  code  if  wiegand  output  with 
facility code is desired. 
To chose the wiegand facility code function: 
First,  enter  program  mode.  Then  enter  [*5],  then  1#, 
then your 1 – 3 digit code (0 – 255), then *. 
 
For example, 

[*5] 1 # 66 *

 will configure the keypad to 

output a 26 bit wiegand protocol with a facility code of 
66. 

 
 
 
 

[*6] Annunciation Control

 Functions 

 
 
0# Yellow LED Enable 

 
Default: 1 (Enabled) 
Enable or disable the yellow LED. When 
enabled, the yellow LED illuminates when any 
key is pressed. 
0 = disabled 
1 = enabled 
To disable the yellow LED: 
First, enter program mode. Then enter [*6], then 0 #, 
then 0 to disable, or 1 to enable, then *. 
 
For  example, 

[*6]  0  #  0  * 

will  disable  yellow  LED 

illumination. 

 
1# Buzzer Enable / Disable 

 
Default: 1 (Enabled) 
Enable or disable the buzzer. When disabled, the 
buzzer will not sound for any condition 
0 = disabled 
1 = enabled 
To disable the buzzer: 
First,  enter  program  mode.  Then  enter  [*6],  then  1#, 
then 0 to disable, or 1 to enable, then *. 
 
For example, 

[*6] 1 # 0 * 

will disable the buzzer for all 

conditions. 

 

2# Correct Code Audio Tone 

Default: 0 (Disabled) 

Enable or disable the audio tone annunciating correct 
code entry. When enabled, a  single 2 tone beep will 
sound when a correct code has been entered.  In the 
case  of  toggled  mode,  the  audio  tone  will  last  for  8 
seconds  (hard-coded)  when  a  correct  code  toggles 
relay one ON; the audio tone will be a single two-tone 
beep, “do-ray”, when a correct code toggles relay one 
OFF. 
0 = disabled 
1 = enabled 
 
To enable the audio tone on correct code entry: 
First,  enter  program  mode.  Then  enter  [*6],  then  2#, 
then (0 to disable, or 1 to enable), then *. 
 
For example, 

[*6] 2 # 1 * 

will enable the audio tone on 

correct code entry. 

 
3# Incorrect Code Audio Tone 

 
Default: 1 (Enabled) 
Enable or disable the audio tone annunciating correct 
code  entry.  When  enabled,  an  audio  tone  will  sound 

Содержание CM-120wV2

Страница 1: ...to Program Keypad Using This Manual Brackets and spaces are not part of the codes They are used here to clarify the operations and group like functions Square brackets are used to indicate that the k...

Страница 2: ...details Using with TX 99 Transmitter Another unique feature of our CM 120 keypad is the ability to plug in our TX 99 transmitter to send the signal wirelessly to our RX 91 or RX 92 receiver the keypa...

Страница 3: ...enable then For example 1 4 0 will disable the anti tailgating feature 5 Backlight Control Enable Disable applies to CM 120W only Default 0 disabled Enable or disable backlight control on keypress Whe...

Страница 4: ...relay on and enter a valid code to toggle the relay back off This is a global setting It is also possible to set for individual users See command 0 further along in this section To program relay 1 op...

Страница 5: ...invalid codes on the buzzer only 2 Stuck key alarm Default 0 Disabled Enable or disable the Stuck key alarm 0 disabled 1 enable The Stuck key alarm will activate the buzzer after 15 seconds factory se...

Страница 6: ...igit code 0 255 then For example 5 1 66 will configure the keypad to output a 26 bit wiegand protocol with a facility code of 66 6 Annunciation Control Functions 0 Yellow LED Enable Default 1 Enabled...

Страница 7: ...closes requires a magnetic door contact 0 disabled default 1 enabled To use this feature First enter program mode Then enter 6 6 0 to disable or 1 to enable then For example 6 6 1 will enable the red...

Страница 8: ...make an input error and have not yet entered just wait 5 seconds and the command memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors featur...

Страница 9: ...Installation Instructions 9...

Страница 10: ...Installation Instructions 10...

Страница 11: ...Installation Instructions 11...

Страница 12: ...Installation Instructions 12...

Отзывы: