Installation Instructions
6
2 = relay 2
3 = both buzzer and relay 2
To program how the “Door forced open alarm”
condition is annunciated:
First, enter program mode. Then enter [*4], then 6#,
then the annunciation code, then *.
For example,
[*4] 6 # 3 *
will configure the keypad to
sound an alarm at both the buzzer and relay 2 if the
door is forced open (without entering a valid code).
NOTE 1:
this feature requires the use of the door
contact input.
NOTE 2:
The alarm will sound continuously until
reset. To reset, enter valid code.
[*5] Wiegand Control Functions
0# Wiegand Protocol selection
Default: 0 (Disabled)
Use to control and select the wiegand protocol.
0 = disabled
1 = 26b raw
2 = 26b raw plus facility code
To enable and select the wiegand output function:
First, enter program mode. Then enter [*5], then 0#,
then the protocol code, then *.
For example,
[*5] 0 # 1 *
will configure the keypad to
output 26 bit wiegand.
NOTE 1
: If wiegand output is chosen, then both
relays, and RF outputs are automatically disabled.
The REX input is also disabled.
See Diagram 2, Page 10 for wiring instruction.
NOTE 2
: If protocol 2 is chosen, then the 2-digit
facility code must be selected in the next step.
1# Wiegand Facility Code
Default: 34 (Camden) (0 – 255 allowed)
Use to select the facility code if wiegand output with
facility code is desired.
To chose the wiegand facility code function:
First, enter program mode. Then enter [*5], then 1#,
then your 1 – 3 digit code (0 – 255), then *.
For example,
[*5] 1 # 66 *
will configure the keypad to
output a 26 bit wiegand protocol with a facility code of
66.
[*6] Annunciation Control
Functions
0# Yellow LED Enable
Default: 1 (Enabled)
Enable or disable the yellow LED. When
enabled, the yellow LED illuminates when any
key is pressed.
0 = disabled
1 = enabled
To disable the yellow LED:
First, enter program mode. Then enter [*6], then 0 #,
then 0 to disable, or 1 to enable, then *.
For example,
[*6] 0 # 0 *
will disable yellow LED
illumination.
1# Buzzer Enable / Disable
Default: 1 (Enabled)
Enable or disable the buzzer. When disabled, the
buzzer will not sound for any condition
0 = disabled
1 = enabled
To disable the buzzer:
First, enter program mode. Then enter [*6], then 1#,
then 0 to disable, or 1 to enable, then *.
For example,
[*6] 1 # 0 *
will disable the buzzer for all
conditions.
2# Correct Code Audio Tone
Default: 0 (Disabled)
Enable or disable the audio tone annunciating correct
code entry. When enabled, a single 2 tone beep will
sound when a correct code has been entered. In the
case of toggled mode, the audio tone will last for 8
seconds (hard-coded) when a correct code toggles
relay one ON; the audio tone will be a single two-tone
beep, “do-ray”, when a correct code toggles relay one
OFF.
0 = disabled
1 = enabled
To enable the audio tone on correct code entry:
First, enter program mode. Then enter [*6], then 2#,
then (0 to disable, or 1 to enable), then *.
For example,
[*6] 2 # 1 *
will enable the audio tone on
correct code entry.
3# Incorrect Code Audio Tone
Default: 1 (Enabled)
Enable or disable the audio tone annunciating correct
code entry. When enabled, an audio tone will sound