 Installation Instructions 

 

 

 

 

 

 

[*0] Set “Latching Mode” for a User 

Default: 0 (Disabled) 
When  enabled,  the  specified  user  keycode  becomes 
a “latching” code. Entering a “latching code will toggle 
the state of relay 1. 
0 = Disabled 
1 = Enabled 

 
NOTE: 

When  the  keypad  is  operating  with  “force 

unique user codes” disabled (the default), users may 
have  identical  codes.  If  individual  control  of  “latching 
mode”  is  required,  consider  enabling  the  “force 
unique user codes” option. 
 
To set a users access to “latching mode”: 
First,  enter  program  mode.  Then  enter  [*0],  then  the 
user  number,  then  ‘#’,  then  (0  to  disable  latching 
mode or 1 to enable it), then *. 
For example, 

[*0] 1 2 # 1 * 

will set user number 12 to 

“latching mode” access. 

 

NOTE:

 If the the Relay Output mode has been set to 

Split,  then  this  latch  mode  affects  only  the  relay 
associated with that user number (memory location) 
If the Relay Output Mode has been set to Sequence, 
then the user Latching mode affects both relays. (So 
both relays toggle on & off simultaneously). 
 

[*4] Alarm Control Functions 

 
0# Incorrect code alarm 
 

Default: 0 (Disabled) 
Use  to  control  how  the  “Incorrect  code  alarm”  is 
annunciated. 
0 = disabled 
1 = buzzer 
2 = relay 2 
3 = both buzzer and relay 2 
 
If the “Incorrect code alarm” is enabled, and triggered, 
a valid code is required to reset. 
 
To program how the “incorrect code alarm” condition 
is annunciated:  
First,  enter  program  mode.  Then  enter  [*4],  then  0#, 
then the annunciation code, then *. 
 
For  example, 

[*4]  0  #  1  * 

will  configure  the  keypad 

indicate  entry  of  the  programmed  count  of  invalid 
codes on the buzzer only. 
 

2# Stuck key alarm 

Default: 0 (Disabled) 
Enable or disable the “Stuck key alarm”. 
0 = disabled 
1 = enable 

The “Stuck key” alarm will activate the buzzer after 15 
seconds  (factory  set  delay)  of  the  key  being  held 
continuously,  and  reset  as  soon  as  the  key  is 
released (or after 10 seconds, whichever occurs first) 
 
To enable the “stuck key alarm”: 
First,  enter  program  mode.  Then  enter  [*4],  then  2#, 
then (0 or 1), then *. 
For example, 

[*4] 2 # 1 * 

will configure the keypad to 

activate the stuck key buzzer. 
 

3# Door Prop open Alarm 
 

Default: 0 (Disabled) 
Use  to  control  how  the  “Door  prop  open  alarm”  is 
annunciated. 
0 = disabled 
1 = buzzer 
2 = relay 2 
3 = both buzzer and relay 2 
 
To  program  how  the  “Door  Prop  open  alarm” 
condition is annunciated: 
First,  enter  program  mode.  Then  enter  [*4],  then  3#, 
then the annunciation code, then *. 
For example, 

[*4] 3 # 3 * 

will annunciate by both the 

buzzer and by activating relay 2. 
 

NOTE  1:

  The  alarm  will  sound  continuously  until 

reset. To reset, enter valid code. 

NOTE 2:

 To set Delay Time, see 

[*3]

 2# on Page 4.

 

 
5# Incorrect code alarm lockout 
 

Default: 0 (Disabled) 
Use to configure the incorrect code alarm lockout. 
0 = disabled 
1 = enabled 
 
To program: 
First,  enter  program  mode.  Then  enter  [*4],  then  5#, 
then the enable/disable code, then *. 
 
For example, 

[*4] 5 # 1 * 

will configure the keypad to 

lockout  for  2  minutes  (factory  set  lockout  duration), 
after  the  incorrect  code  count  alarm  limit  is  reached. 
During the lockout period, all keypad entry (including 
correct codes) is ignored. 
There is an automatic reset after 2 minutes. 
(See 2# on Page 3 of manual for setting code count) 
 

6# Door Forced open Alarm 
 

Default: 0 (Disabled) 
Use  to  control  how  the  “Door  forced  open  alarm”  is 
annunciated. 
0 = disabled 
1 = buzzer 

Содержание CM-120wV2

Страница 1: ...to Program Keypad Using This Manual Brackets and spaces are not part of the codes They are used here to clarify the operations and group like functions Square brackets are used to indicate that the k...

Страница 2: ...details Using with TX 99 Transmitter Another unique feature of our CM 120 keypad is the ability to plug in our TX 99 transmitter to send the signal wirelessly to our RX 91 or RX 92 receiver the keypa...

Страница 3: ...enable then For example 1 4 0 will disable the anti tailgating feature 5 Backlight Control Enable Disable applies to CM 120W only Default 0 disabled Enable or disable backlight control on keypress Whe...

Страница 4: ...relay on and enter a valid code to toggle the relay back off This is a global setting It is also possible to set for individual users See command 0 further along in this section To program relay 1 op...

Страница 5: ...invalid codes on the buzzer only 2 Stuck key alarm Default 0 Disabled Enable or disable the Stuck key alarm 0 disabled 1 enable The Stuck key alarm will activate the buzzer after 15 seconds factory se...

Страница 6: ...igit code 0 255 then For example 5 1 66 will configure the keypad to output a 26 bit wiegand protocol with a facility code of 66 6 Annunciation Control Functions 0 Yellow LED Enable Default 1 Enabled...

Страница 7: ...closes requires a magnetic door contact 0 disabled default 1 enabled To use this feature First enter program mode Then enter 6 6 0 to disable or 1 to enable then For example 6 6 1 will enable the red...

Страница 8: ...make an input error and have not yet entered just wait 5 seconds and the command memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors featur...

Страница 9: ...Installation Instructions 9...

Страница 10: ...Installation Instructions 10...

Страница 11: ...Installation Instructions 11...

Страница 12: ...Installation Instructions 12...

Отзывы: