10. Connections

When you connect the amplifier to other equipment, turn off the power and 
unplug all of the equipment from the supply source. Failure to do so may 
cause an electric shock and serious personal injury. Read the user manual 
of the other equipment carefully and follow the instructions when making 
the connections.

11. Lightning

For additional protection of this amplifier during lightning storms or when 
it is left unattended and/or unused for long periods of time, unplug it from 
the wall outlet. This will prevent damage to the amplifier due to lightning 
and power line surges. Disconnection from the mains power supply can 
only be achieved by removing the plug from the mains socket and by 
external disconnecting all poles from the mains.

12. Damages that Require Service

Unplug this amplifier from the mains supply and refer to your dealer/dis-
tributor or other authorized repair workshop if any of the following situa-
tions occur: 

 if liquid has been spilled or objects have fallen into the amplifier
  if the amplifier has been exposed to rain or moisture 
 if the amplifier has been dropped or damaged in any other way
 if the power supply cord or plug has been damaged
  when the amplifier exhibits a distinct change from its normal function 

or performance

  in case the amplifier has been used in a dusty environment for quite 

a period of time

13. Servicing

All service and repair work must be carried out by a dealer/distributor 
authorized by 

CAMCO

. Do not attempt to service this amplifier yourself. 

As opening or removing covers may expose you to dangerous voltage or 
other hazards, the amplifier may only be opened by qualified personnel. 
Please refer to your dealer/distributor.

14. Spare Parts

When spare parts are required, please ensure that the dealer/distribu-
tor only uses spare parts specified by the manufacturer. The use of un-
authorized spare parts may result in injury and/or damage through fire or 
electric shock or other electricity-related hazards.

15. Safety Check

Upon completion of any service or repairs to this product, ask the dealer/
distributor to perform safety checks to determine that the amplifier works 
properly. 
Recommendations on how to carry out the safety test can be found in 
DIN VDE 0701-1 “Maintenance, Modification and Test of Electronic Appli-
ances“.

16. Cleaning

Unplug this amplifier from the wall outlet before cleaning. Do not use liquid 
or aerosol cleaners. Clean only with dry cloth.

17. Packaging and Shipping

When shipping the 

VORTEX SILVER SERIES V8

 amplifier, always use the 

original shipping carton and packing materials. For maximum protection 
repack the unit as it was originally packed at the factory.

IMPORT

ANT SAFETY INSTRUCTIONS

Содержание V8

Страница 1: ......

Страница 2: ...il to the exclusion of the national translation on hand Copyright 2010 2012 by CAMCO Produktions und Vertriebs GmbH f r Beschallungs und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany Telephone...

Страница 3: ...ous injury and serious damage to the prod uct Any mounting of the amplifier should follow the manufacturer s instructions Only mounting accessory shall be used which is recommended by the manufac ture...

Страница 4: ...a distinct change from its normal function or performance in case the amplifier has been used in a dusty environment for quite a period of time 13 Servicing All service and repair work must be carried...

Страница 5: ...THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE OUTPUT CONNECTORS THAT COULD POTENTIALLY BE LIFE THREATENING THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF UNI...

Страница 6: ...Germany Declares That The Product With The Model Name CAMCO Power amplifier VORTEX SILVER SERIES V8 Conforms To The Following Standards EN60065 Safety EN55103 1 Emission EN55103 2 Immunity The operat...

Страница 7: ...2 Power On Off P 18 4 3 Indicators 4 3 1 Input Selection LED 4 3 2 Output Mode LED 4 3 3 Clip LED 4 3 4 Signal LED 4 3 5 Device Identifier LED 4 3 6 DSP LED 4 3 7 Uman LED P 19 4 4 Main Menu 4 5 Power...

Страница 8: ...elopers are able to take the next steps in building a more coherent future with tools that really integrate together The ancient cultures developed an understanding of our world by a reali sation of t...

Страница 9: ...PS with automatic voltage range selection for 120 V 230 V operation which significantly reduces the weight and size only 2U of the amplifier Using SMPS the seamlessly regulated symmetrical supply volt...

Страница 10: ...ion LED 10 DSP LED 4 Output Mode LED 11 Uman Network Status LED 5 Clip LED Channel A 12 Cooling Air Inlet Vents 6 Signal LED Channel A 13 Removable Air Filter System 7 Device Indicator LED 2 4 V8 The...

Страница 11: ...ions to restore the original factory settings 1 The reset Settings option will restore all amplifier parameters and a reboot of the amplifier will take place Note that this type of reset is also done...

Страница 12: ...ker for 120 V operation respectively Please do NOT use much larger mains breakers than recommended here and especially do NOT connect several V8 amplifiers to one sin gle very large breaker Always res...

Страница 13: ...very high when demanding large output powers Please refer to following table for an overview of mains currents and power cunsuption under differ ent operating conditions Operating condition Mains cur...

Страница 14: ...dB 1 4 V V8 5100 W 2 4000 W 4 2300 W 8 5 08 V 6 38 V 6 80 V 2 54 V 3 19 V 3 40 V 40 dB 3 4 2 AES Input The digital AES XLR input accepts any AES EBU signals pro or consumer format in 16 18 20 or 24 b...

Страница 15: ...nnel B ground Pin 2 Channel A amplifier output Pin 2 Channel A ground WARNING SPEAKON connectors marked with the lightning flashes indicate high voltages that are potentially life threatening Wiringto...

Страница 16: ...th SPEAKON connectors where possible for current sharing Not doing so may cause permanent damage to the connectors and may consid erably reduce performance 3 6 4 Mono Bridge Operation One channel mono...

Страница 17: ...e to the selected menu item activate selected items confirm changes Shortcut key touch and hold 2 s to access the Quick Access Menu 3 A button Select channel A related parameters 4 B button Select cha...

Страница 18: ...Hot Key accessible from all menus and screens Touch and hold MENU 2 s let you directly jump to the Home Menu You can step back to the previous screen by touching the MENU button The Home Menu can be...

Страница 19: ...LED is illuminated when the input signal level is suffi ciently high for creating an output voltage of approx 4 V this corresponds to an output power of approx 4 W over a 4 load Note that these LED s...

Страница 20: ...end ent approach The Clip Limiter works on each channel independently except for the two mono operation modes The Clip Limiter has three different modes Off Slow and Fast which can be selected in the...

Страница 21: ...tput voltage These limits will be set automatically This improves reliability without de grading sound quality when driving complex loads 4 6 Mains Protections 4 6 1 Inrush Current Limitation Within 2...

Страница 22: ...demanding for a mains distribution even with this limiter set to low values See also chapter 3 3 3 If active this limitation is indicated in the display s Signal Monitor and also by a red LED behind...

Страница 23: ...is working If the amplifier has been powered down standby this LED will be slowly pulsating indicating that the SMPS is off but ready to be switched on again at any time Note that the picture shows th...

Страница 24: ...lter no tools are required first gently slide the whole plastic filter assembly a few millimeters to the left and lift it from the front panel Next beginning on one of the long sides carefully unclip...

Страница 25: ...operation typical values may be subjected to component tolerances Mono Bridge 4600 W 16 8000 W 8 10200 W 4 5000 W 16 Peak 9800 W 8 Peak 10600 W 4 Peak Parallel Mono 4600 W 4 8000 W 2 10200 W 1 5000 W...

Страница 26: ...ower on off transients temperature monitoring of transformers and heatsinks output DC protection temperature dependent SOA protection intelligent mains fuse protection SMPS overload protection overcur...

Страница 27: ...ormance will decrease with lower mains voltages than the rated 230 V 120 V and slightly increase with higher mains voltages Dual voltage SMPS with automatic voltage range selection 230 V 120 V 50 60 H...

Страница 28: ...60 55 50 45 d B 60 10 50 40 30 20 10 0 dBu USER MANUAL VORTEX SILVER SERIES V8 P 27 Figure 6 1 Gain vs frequency 120 W output power 4 channel 1 channel 2 Measurement of a typical performance Figure 6...

Страница 29: ...10 k Hz USER MANUAL VORTEX SILVER SERIES V8 P 28 Figure 6 6 Channel separation vs frequency 250 W 2 channel 1 channel 2 Measurement of a typical performance Figure 6 8 Common mode rejection ratio chan...

Страница 30: ...THD Peak Power 0 1000 2000 3000 4000 5000 6000 Watts Impedance 5300 5100 4900 2500 1250 4000 2300 1250 USER MANUAL VORTEX SILVER SERIES V8 P 29 Figure 6 9 SMPTE intermodulation distortion 60 Hz and 7...

Страница 31: ...ect AC voltage operation with faulty peripheral equipment modification or alteration without prior factory ap proval service by an unauthorized service center and normal wear and tear Amplifiers on wh...

Страница 32: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 33: ...position to judge the safe functioning of power amplifiers based on technical rules according to IEC 60065 IEC 60065 DIN EN 60065 Safety Requirements for Audio Video or simlar Electronic Appliances I...

Страница 34: ...3 Mailing Address CAMCO Produktions und Vertriebs GmbH f r Beschallungs und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany Telephone 49 0 2762408 0 Facsimile 49 0 2762408 10 Internet www camcoa...

Страница 35: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 36: ...www camcoaudio com...