WARNING:
Do not attempt to move the Air Curtain Ultra Refrigerator until the unit is turned off, the power cord is unplugged and out-of-the-way, or
secured around rear handle.
Door must be securely shut and all caster locks released.
Maneuver unit by grasping the side handles or rear handle.
CAUTION:
The unit is designed for internal use and not designed for outdoor all-terrain
transport. Though the compressor has been located at the bottom of the unit, lowering the center-of-gravity, the distribution of weight of the unit and
food product makes the unit top heavy. Be cautious when approaching uneven flooring (such as door sills, drains, thresholds, etc).
OPEN DOOR OPERATION
1. Set Temp. Pre-Chill empty cabinet to minimum of 34°F to 36°F (1°C to 2.2°C) with door closed minimum of one (1) hour.
Load cabinet from bottom to top with PRE-CHILLED FOOD AT 40F (4.4°C) or colder. Push trays to rear of wall.
FULL SWING DOOR WITH MAGNETIC HOLD OPEN CATCH:
Door opens to lay flat against cabinet and is secured by a magnetic door edge.
Note:
Prior to “operating with door open”, food product should be prechilled to an internal food temperature of 36°F (2.2°C) or below.
2. After loading, close cabinet door and allow inside temperature to re-stabilize to designated set temperature (or to desired internal temperature
of food product).
3. Unload cabinet from top to bottom. Empty trays can be removed or left in the unit after unloading. Trays will not appreciably effect the overall
performance of the unit, however, keeping the 10 tray slides racked in the cabinet after trays have been emptied of food product may result in
slightly better performance.
4. This unit is equipped with an automatic condensate evaporator. To prevent water spills, leave unit plugged in with door closed after use. A
recommendation would be to defrost after use as well, to free coil from ice build up formed during use.
5. Your unit is equipped with a smart controller. During open door operation your unit knows the door is open. When operating your unit with door
open the display will show “OPEn” and an internal count down timer will start. Your unit will allow open door operation for a maximum of 2 hours.
During the open door operation your unit will not go into an auto or timed interval defrost cycle. During open door operation the cooling system
will remain on. This ensures you will receive optimum open door performance. If door is open longer than 2 hours an open door alarm will be
activated. Display will flash “OPEn” and beep three times every ten seconds.
To terminate the open door alarm, the door must be closed
and remain closed for five minutes. If door open alarm is activated, unit will activate a hard defrost cycle five minutes after door is
closed.
Door must remain closed until defrost cycle is complete, approximately 30 minutes.
6. INTERNAL CABINET TEMPERATURE WILL ELEVATE DURING DEFROST CYCLE.
7. For performance values with door open,
see section
V
.
8. For trouble shooting and addressing performance issues,
see section
XII
.
WARNING:
RISK OF ELECTRICAL SHOCK. DISCONNECT ELECTRICAL POWER SUPPLY
BEFORE CLEANING ANY PARTS OF THE UNIT OR PRIOR TO ANY SERVICE.
Cleaning the Condenser:
The most important thing you can do to insure a long, reliable service life for your Cambro Air Curtain ultra Refrigerator is to regularly clean
the condenser (compressor) coil. The condensing unit requires regularly scheduled cleaning to keep the finned condenser clean of link and
dust accumulation. Keeping the condenser clean allows the cabinet to operate efficiently, use less energy, and achieve top performance
values.
VIII - Transporting
IX - Open Door Operation
X - General Cleaning & Maintenance