Page | 11
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the
appliance is manufactured for.
This natural gas appliance is designed to operate on natural gas ONLY, at a pressure regulated at 4
”
water column (W.C.) when equipped with the correct natural gas orifices on the valves and a natural
gas regulator on the supply line regulated at the residential meter.
NOTE:
Supply line must be ½” ID from gas supply to regulator.
We recommend consulting a local licensed plumber to insure proper gas volume.
IMPORTANT:
Never connect the appliance to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company
representative.
NG Regulator
IMPORTANT:
NEVER
use appliance without leak testing this
connection.
Natural gas regulator model: GR120N / RN1204A / XD07A
Gas pressure: 4
” Water Column (W.C.)
Maximum rate working pressure: 1/2 PSIG
Natural Gas Supply Connection and Disconnection
1.
Make sure all burner valves are in the “OFF” position.
2. To connect: Push back sleeve of socket, insert plug, and release sleeve. Push plug until sleeve
snaps forward locking plug into socket. (THIS AUTOMATICALLY TURNS ON GAS.)
3. To disconnect: Push sleeve back and pull out plug. (THIS AUTOMATICALLY SHUTS OFF GAS.)
4. Connected hose assembly shall be of adequate length and capacity for intended application. Final
assembly must be tested for leaks.
Natural Gas Hook-up
Содержание HEAT HTSB1
Страница 26: ...Page 26 This page left intentionally blank ...