11
CAMBO
® Wide RS 5000 series
K. WTS TILT-SWING LENS PANELS
The WTS panel allows an angle adjustment b5 and -5 degrees in both
swing and tilt direction for setting Scheimpflug corrections. These can be used
separately as well as simultaneously, using the 2 adjustment knobs. The lens
plane and CCD are parallel when the tilt (T) and swing (S) indicators are set to
zero on the scale. This zero-position is reached when the bearing snaps into the
lock, where the drive knobs become slightly loose by purpose.
To apply tilt only use tilt knob, to apply swing only use swing knob. When need-
ed, a combination of both can be applied.
Note: do not force beyond the +5/-5 boundary marks.
L. LENS CAST
Under certain circumstances there may be occurrence of lens cast, caused by
the light striking the CCD under an angle due to either shifts or very short focal
length. The effect may differ quite a lot from one CCD to another and is not a
constant factor. This effect is acknowledged by all digital back manufacturers
and each have their own software solution for this.
Swing knob
Tilt knob
WTS lens panel
Tilt/swing scale
Swing index
Tilt index
Helical mount
Lens