Chapter 8: Ethernet Protocols
Configuring LLDP
phn-3963_004v000
Page 8-85
Parameter
Definition
Reinit Delay (Seconds) Defines the minimum time, in seconds, the system waits after
the LLDP Admin status becomes Disabled until it will process a
request to reinitialize LLDP. For instructions on disabling or
enabling LLDP on a port, see
In this release, the Reinit Delay is set at 2.
Table 43 LLDP Configurable Configuration Parameters
Parameter
Definition
TX Interval (Seconds)
Defines the interval, in seconds, at which LLDP frames are
transmitted. You can select a value from 5 to 32768. The default
value is 30.
Notification Interval
(Seconds)
Defines the interval, in seconds, between transmissions of
LLDP notifications during normal transmission periods. You
can select a value from 5 to 3600. The default value is 10.
Hold Multiplier
Defines the time-to-live (TTL) multiplier. The TTL determines
the length of time LLDP frames are retained by the receiving
device. The TTL is determined by multiplying the TX Interval by
the Hold Multiplier.
You can select a value from 2 to 10. The default value is 4.
Configuring the LLDP Port Parameters
To enable LLDP per port and determine how LLDP operates and which TLVs are sent for each port:
1.
Select Ethernet > Protocols > LLDP > Advanced > Configuration > Port Configuration. The LLDP
Port Configuration page opens.