Chapter 6: Compliance with safety standards

279

Calculat ed d ist ances and p o w er co m p liance m arg ins

The following tables show calculated minimum separation distances, recommended distances and
resulting margins for each frequency band and antenna combination for the USA and Canada. These are
conservative distances that include compliance margins. At these and greater separation distances, the
power density from the RF field is below generally accepted limits for the general population.

450 Platform Family ODU adheres to all applicable EIRP limits for transmit power when operating in MIMO
mode. Separation distances and compliance margins include compensation for both transmitters.

Explanation of terms used in the following tables:

l

P burst – maximum average transmit power during transmit burst (Watt)

l

P – maximum average transmit power of the radio (Watt)

l

G – total transmit gain as a factor, converted from dB

l

S – power density (Watt/m2)

l

d – minimum safe separation distance from point source (meters)

Table 126 :FCC minimum safe distances – PMP 450m 3 GHz and 5 GHz (5.1 GHz, 5.2 GHz, 5.4 GHz and 5.8

GHz)

Band (GHz)

Antenna

PG (W)

S (W/ m2)

d (m)

3.65

90° sector

33.9

10

0.52

4.9

90° sector

174

10

1.08

5.1

90° sector

3.38

10

0.16

5.2

90° sector

0.85

10

0.08

5.4

90° sector

0.85

10

0.08

5.8

90° sector

3.38

10

0.16

Table 127 :FCC minimum safe distances – PMP/PTP 450b 3.65 GHz, 4.9 GHz, 5.1 GHz, 5.2 GHz, 5.4 GHz and

5.8 GHz

Band (GHz)

Antenna

P
(W)

G
(dBi)

S
(W/ m2)

d
(m)

3.65

Dish

0.199

20.0

10.0

0.40

4.9

Dish

0.501

24.0

10.0

1.00

Patch Array

0.501

17.0

10.0

0.45

On-board

0.501

0

10.0

0.06

5.1

Dish

0.501

24.0

10.0

1.00

Patch Array

0.501

17.0

10.0.

0.45

On-board

0.501

0

10.0

0.06

Содержание PMP 450 AP

Страница 1: ...Guide 333333333 PLANNING AND INSTALLATION GUIDE PMP PTP 450 Series System Release 21 0 Covers PMP 450 AP PMP 450 SM PTP 450 BH PMP 450d PMP 450i PTP 450i PMP 450b PTP 450b PMP 450m PMP 450 MicroPoP PMP PTP 450b Retro ...

Страница 2: ...gly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either directly or by im...

Страница 3: ...a specific information 16 Renseignements specifiques au Canada 16 EU Declaration of Conformity 17 Specific expertise and training for professional installers 17 Ethernet networking skills 17 Lightning protection 18 Problems and warranty 18 Reporting problems 18 Repair and service 18 Hardware warranty 18 Security advice 18 Warnings cautions and notes 19 Warnings 19 Cautions 19 Notes 19 Caring for t...

Страница 4: ...me Protocol NTP 42 cnMaestro 43 Wireless Manager WM 43 Radio recovery mode 44 Chapter 2 System hardware 46 System Components 46 Point to Multipoint PMP 46 Backhaul PTP 49 450 Platform Family interfaces 51 ATEX HAZLOC variants 61 Diagnostic LEDs 63 Power supply options 73 Power supply PMP 450m Series 74 Power supply PMP PTP 450i Series 74 Power supply PMP PTP 450b Series 78 Power supply PMP PTP 450...

Страница 5: ...utdoor copper Cat 5e Ethernet cable 95 SFP module kits 95 Main Ethernet port 97 Aux port 98 Ethernet cable testing 101 Lightning protection unit LPU and grounding kit 102 DC LPU and Grounding Kit 103 Cable grounding kit 106 Antennas and antenna cabling 106 Antenna requirements 106 Supported external AP antennas 107 Supported external BH SM antenna 107 RF cable and connectors 107 Antenna accessorie...

Страница 6: ...20 Ordering the components 120 Chapter 3 System planning 133 Typical deployment 133 ODU with PoE interface to PSU 133 Site planning 138 Site selection for PMP PTP radios 138 Power supply site selection 139 Maximum cable lengths 139 Grounding and lightning protection 139 ODU and external antenna location 141 ODU ambient temperature limits 141 ODU wind loading 141 Hazardous locations 145 Drop cable ...

Страница 7: ...quency reuse 155 Link planning 160 Range and obstacles 160 Path loss 161 Calculating Link Loss 161 Calculating Rx Signal Level 161 Calculating Fade Margin 162 Adaptive modulation 162 Planning for connectorized units 162 When to install connectorized units 163 Choosing external antennas 163 Calculating RF cable length 5 8 GHz FCC only 163 Data network planning 164 Understanding addresses 164 Dynami...

Страница 8: ...nning for RADIUS operation 174 Filtering protocols and ports 175 Encrypting downlink broadcasts 177 Isolating SMs in PMP 178 Filtering management through Ethernet 178 Allowing management from only specified IP addresses 178 Configuring management IP by DHCP 178 Controlling PPPoE PADI Downlink Forwarding 179 Remote AP Deployment 179 Remote AP RAP Performance 180 Example Use Case for RF Obstructions...

Страница 9: ...inventory 190 Preparing tools 190 Testing system components 190 Unpacking Components 191 Preparing the ODU 191 Configuring Link for Test 198 Configuring the management PC 198 Logging into the web interface AP SM BH 199 Using the Quick Start Configuration Wizard of the AP BHM 199 Chapter 5 Installation 200 ODU variants and mounting bracket options 200 Mount the ODU LPU and surge suppressor 201 Atta...

Страница 10: ...it 263 Disconnecting an RJ45 and gland from a unit 265 Installing ODU 265 Installing a 450 Platform Family AP 265 Installing a 450 Platform Family SM 266 Installing a 450 Platform Family BHM 267 Installing a 450 Platform Family BHS 268 Configuring the Link 269 Monitoring the Link 269 Installing the AC Power Injector 269 Installing CMM4 270 Supplemental installation information 270 Stripping drop c...

Страница 11: ...pliance margins 279 Tx power limits for PMP 450 MicroPoP 288 Hazardous location compliance 289 ATEX 289 Chapter 7 Compliance with radio regulations 290 Type approvals 290 Brazil specific information 292 Brazil notification 292 Brazil certification numbers 292 Australia Notification 292 Regulatory Requirements for CEPT Member States www cept org 292 ...

Страница 12: ...phone number list http www cambiumnetworks com contact Address Cambium Networks Limited Linhay Business Park Eastern Road Ashburton Devon TQ13 7UP United Kingdom Purpose Cambium Networks Point to Multi Point PMP Point To Point PTP 450 documents are intended to instruct and assist personnel in the operation installation and maintenance of the Cambium PMP PTP equipment and ancillary devices of 450 P...

Страница 13: ...orized Integrated PTP 450 l BHM BHS 900 MHz 3 5 GHz 3 65 GHz 5 GHz l Connectorized Integrated PMP 450d l SM 5 GHz 450i Series Refers to 450i Series devices in the following configurations PMP 450i l AP 900 MHz 3 GHz 5 GHz l Connectorized Integrated l SM 3 GHz 5 GHz l Connectorized Integrated PTP 450i l BHM BHS 3 GHz 5 GHz l Connectorized Integrated 450b Series Refers to 450b Series devices in the ...

Страница 14: ...sections Sections are not numbered but are individually named at the top of each page and are listed in the table of contents Feedback We appreciate feedback from the users of our documents This includes feedback on the structure content accuracy or completeness of our documents To provide feedback visit our support website https support cambiumnetworks com Caution This device complies with Part 1...

Страница 15: ... range of permissible values for maximum antenna gain and feeder cable losses are included in this user guide together with a sample calculation The product GUI automatically applies the correct conducted power limit to ensure that it is not possible for the installation to exceed the EIRP limit when the appropriate values for antenna gain and feeder cable losses are entered into the GUI Avoidance...

Страница 16: ...r radar installations Other variants of the 450 Platform Family are available for use in the rest of the world but these variants are not supplied to Canada except under strict controls when they are needed for export and deployment outside Canada Renseignement s specifiques au Canada Attention Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de l...

Страница 17: ...est founie dans le 450 Platform Configuration Guide EU Declarat ion of Conformit y Hereby Cambium Networks declares that the Cambium 450 Series 450b Series 450i Series and 450m Series Wireless Ethernet Bridge complies with the essential requirements and other relevant provisions of Radio Equipment Directive 2014 53 EU The declaration of conformity may be consulted at https www cambiumnetworks com ...

Страница 18: ...mbium Networks warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service Cambium shall within this time at its own option either repair or replace the defective product within thirty 30 days of receipt of the defective product Repaired or replaced product will be subject to the origin...

Страница 19: ...lowing the instructions in the warning Caut ions Cautions precede instructions and are used when there is a possibility of damage to systems software or individual items of equipment within a system However this damage presents no danger to personnel A caution has the following format Caution Caution text and consequence for not following the instructions in the caution Not es A note means that th...

Страница 20: ...mbiumnetworks com support compliance Disposal of surplus packaging Do not dispose of surplus packaging in landfill sites In the EU it is the individual recipient s responsibility to ensure that packaging materials are collected and recycled according to the requirements of EU environmental law In non EU count ries In non EU countries dispose of Cambium equipment and all surplus packaging in accord...

Страница 21: ...y Purpose Cambium 450 Platform Family products are designed for Ethernet bridging over point to point and point to multipoint microwave links in unlicensed and lightly licensed frequency bands 900MHz 2 4 GHz 3 5 3 65 GHz and 4 9 to 5 925 GHz Users must ensure that the 450 Platform Family complies with local operating regulations The 450 Platform Family acts as a transparent bridge between two or m...

Страница 22: ...packet rate compare 450 Series l 5 GHz Integrated with 14x14 MU MIMO antenna 3 GHz Integrated with 8x8 MU MIMO antenna l 5 GHz ports Gigabit copper power port combined 100BaseT port with power out and SFP port 2 5G Copper SFP l 3 GHz ports Gigabit copper Ethernet port without Power Ethernet 100 1000BaseT Auxiliary with power out SFP1 SFP2 l 45 bps Hz spectral efficiency in a single sector and 90 b...

Страница 23: ... 450m AP 4900 to 5925 MHz Integrated 15 dBi 90 MU MIMO sector antenna 3 GHz PMP 450m AP 3300 to 3900 MHz Integrated 16 dBi 90 MU MIMO sector antenna PMP PTP 450 i Series The PMP PTP 450i Series is a high performance wireless bridge for Ethernet traffic It is capable of operating in line of sight LOS near LOS and non LOS propagation conditions It supports 900 MHz 3 GHz and 4 9 to 5 925 GHz frequenc...

Страница 24: ...etwork application l MIMO B Mode This technique provides for the ability to double the throughput of a radio transmission under proper RF conditions Different data streams are transmitted simultaneously on two different antennas l MIMO A mode This mode of operation has same modulation levels as the MIMO B mode namely QPSK 16 QAM 64 QAM and 256 QAM This mode increases system reliability in the link...

Страница 25: ... 928 MHz 3 3 to 3 9 GHz 4 9 to 5 925 GHz Tx Power conducted Max 25 dBm 3 GHz Max 27 dBm 5 GHz Max 25 dBm 900 MHz Channel bandwidth 5 7 10 15 20 30 and 40 MHz Note All bands do not support all channel bandwidths For more information refer to this link Spectral efficiency Up to 7 5 bps Hz Timing synchronization CMM4 CMM5 or UGPS cnPulse Data rate Up to 310 Mbps 40 MHz channel BW for PMP PTP Frequenc...

Страница 26: ...torized Use with an external antenna PMP 450i SM 3 3 to 3 9 GHz Integrated 19 dBi SM BH with MARS antenna Connectorized Use with an external antenna 4 9 to 5 925 GHz support 4 9 5 1 5 2 5 4 and 5 8 GHz Integrated 23 dBi flat panel antenna Connectorized Use with an external antenna PTP 450i BH 3 3 to 3 9 GHz Integrated 19 dBi SM BH with MARS antenna Connectorized Use with an external antenna 4 9 to...

Страница 27: ...dition LOS near LOS or non LOS Range PTP Up to 186 mi or 299 km depending on configuration for all bands PMP Up to 40 mi or 64 km Duplexing TDD symmetric and asymmetric Connectivity 100 1000Base T Ethernet Main port with PoE input Operating frequencies 3 3 to 3 9 GHz 4 9 to 5 925 GHz Tx Power conducted Max 29 dBm 3 GHz Max 27 dBm 5 GHz Channel bandwidth 5 7 10 15 20 30 and 40 MHz Note All bands do...

Страница 28: ...um s point to multipoint and point to point solution with up to 310 Mbps usable throughput l State of the art MIMO Multi In Multi Out technology l Efficient GPS synchronized scheduled TDD operation for easy Access Point site deployment and performance that is consistent regardless of subscriber loading l A range of cost effective subscriber device solutions to meet the business case of a network a...

Страница 29: ...or more information refer to this link High spectral efficiency Up to 7 5 bps Hz Timing synchronization CMM4 CMM5 internal GPS or UGPS cnPulse Data rate Up to 310 Mbps 40 MHz channel BW for PMP PTP Frequency bands The PMP PTP 450 Series ODU can operate in the following bands l 900 MHz band 902 to 928 MHz SM and BH l 2 4 GHz band 2400 to 2483 MHz l 3 5 GHz band 3300 to 3600 MHz l 3 65 GHz band 3500...

Страница 30: ...ed patch Integrated 19 dBi Flat Plate integrated patch 5 GHz 5 4 and 5 8 GHz Connectorized Use with an external antenna Integrated 9 dBi H V integrated patch Integrated 25 dBi H V Integrated dish PTP 450 BH 902 to 928 MHz Connectorized Use with an external antenna 3 5 3 65 GHz Connectorized Use with an external antenna Integrated 8 dBi Dual Slant 5 GHz 5 4 and 5 8 GHz Connectorized Use with an ext...

Страница 31: ...croPoP Series characteristics Characteristic Value Topology PMP Wireless link condition LOS near LOS or non LOS Range Up to 2 miles License key available to unlock range up to 40 miles Duplexing TDD symmetric and asymmetric Connectivity 100 1000Base T Ethernet Main port with PoE input Operating frequencies 4 9 to 5 925 GHz Tx Power conducted Max 27 dBm 5 GHz Channel bandwidth 5 7 10 15 20 30 and 4...

Страница 32: ...e provides the maximum transfer rates to the device l 3 5 mm audio jack allows direct connection of headphones without any adapters l Updated FPGA enhances Packet Processing Power more than 4 times that of the 450m SM l Capable of up to 300 Mbps aggregate in a 40 MHz channel l Same form factor of the PMP 450 SM l The form factor allows use of existing Offset Reflector dishes Table 11 PMP 450 Retro...

Страница 33: ...erability for 450 m 450 i 450 b 450 series The supported interoperability among various 450m 450i 450 Series hardwares are listed below Table 13 Supported Interoperability for PMP Band AP SM 4 9 5 1 5 2 and 5 9 GHz PMP 450m AP PMP 450i SM PMP 450b SM PMP 450b Retro SM 4 9 5 1 5 2 and 5 9 GHz PMP 450i AP PMP 450i SM PMP 450b SM PMP 450b Retro SM PMP 450 MicroPoP 5 4 and 5 8 GHz PMP 450m AP PMP 450i...

Страница 34: ...a power supply PSU see PMP PTP 450 Platform Family typical bridge deployment The ODU provides the following interfaces Ethernet port This provides proprietary power over Ethernet and connection to the management and or data networks Note PMP 450m 3 GHz has a separate power and data interface Figure 1 PMP PTP 450 Platform Family typical bridge deployment Note Lightning Protection and Power supply d...

Страница 35: ...the following product variants l The ODU is supplied in the following regional variants l FCC intended for deployment in the USA l IC intended for deployment in Canada l EU intended for deployment in countries of the European Union or other countries following ETSI regulations l Rest of the World RoW intended for deployment in countries other than USA and EU countries l Integrated connectorized OD...

Страница 36: ...using ground cables For more information about these components including interfaces specifications and Cambium part numbers refer to Chapter 2 System hardware W ireless operation This section describes how the 450 Platform Family wireless link is operated including modulation modes power control and security Time division duplexing The system uses Time Division Duplexing TDD one channel alternate...

Страница 37: ...urable to one of the following values 5 7 10 15 20 30 and 40 MHz Higher bandwidths provide greater link capacity at the expense of using more bandwidth Systems configured for a narrower channel bandwidth provide better receiver sensitivity and can also be an appropriate choice in deployments where the amount of free spectrum is limited Note The channel bandwidth must be configured to the same valu...

Страница 38: ...nd 3X MIMO A 64 QAM and 8X MIMO B and 4X MIMO A 256 QAM If received power varies due to distance between the AP BHM and the SM BHS or due to obstructions or if interference affects the RF environment the system automatically and dynamically adjusts the links to the best operation level The system chooses its modulation rate dynamically based on an internal ARQ Automatic Repeat reQuest error contro...

Страница 39: ...hnologies used to multiply the capacity of a wireless connection without requiring more spectrum Although traditional MIMO techniques are focused on increasing the bandwidth available between two wireless nodes multi user MIMO MU MIMO applies these technologies to increase overall wireless network capacity by allowing an access point to communicate wirelessly with more than one wireless node at on...

Страница 40: ...Family management system including the web interface installation configuration alerts and upgrades Management agent The 450 Platform Family radios are managed through an embedded management agent Management workstations network management systems or PCs can be connected to this agent using the module s Ethernet port or over the air SM BHS The management agent supports the following interfaces l H...

Страница 41: ...l When identity based user accounts are configured a security officer can define from one to four user accounts each of which may have one of the four possible roles l ADMINISTRATOR who has full read and write permissions This is the level of the root and admin users as well as any other administrator accounts that one of them creates l INSTALLER who has permissions identical to those of ADMINISTR...

Страница 42: ...lized AP and SM user name and password management Allows AP and SM usernames and access levels Administrator Installer Technician and Read Only to be centrally administered in the RADIUS server instead of on each radio and tracks access events logon logoff for each username on the RADIUS server This accounting does not track and report specific configuration actions performed on radios or pull sta...

Страница 43: ... Configuring cnMaestroTM Connectivity in Configuration Guide for details W ireless Manager W M Cambium Networks Wireless Manager 4 0 is also used for managing 450 Platform Family networks You can achieve better uptime through better visibility of your network with the Cambium Wireless Manager This network management software tool offers breakthrough map based visualization capabilities using embed...

Страница 44: ...BHM accepts this command from only the IP address that specified in the Configuration page of ODU l For convenience Network Updater automatically sets this Configuration parameter in the AP BHM to the IP address of the Network Updater server when the server performs any of the update commands l Allows you to choose among updating l Entire network l Only elements that you select l Only network bran...

Страница 45: ...P 450m in Configuration Guide for more details Default Mode or Default Plug 450 Series A default plug is available to provide access to a module whose password and or IP address have been forgotten This plug allows the 450 Series ODUs to be accessed using IP address 169 254 1 1 and no password During the override session you can assign any new IP address and set either or both user passwords displ...

Страница 46: ...form Family components System Components Point t o Mult ipoint PMP The PMP radio is a transceiver device It is a connectorized or radiated outdoor unit containing all the radio networking and surge suppression electronics It can be purchased as l Access Point Module AP l Subscriber Module SM PMP 450 Platform Family Integrated or Connectorized ODU The PMP 450i Series and PMP 450 Series ODUs are sup...

Страница 47: ...zed 902 928 MHz 5 7 10 15 20 MHz 25 dBm 3 GHz PMP 450i AP All No Encryption Connectorized 3300 3900 MHz 5 7 10 15 20 30 40 MHz 25 dBm Integrated 16 dBi 5 GHz PMP 450i AP FCC IC EU RoW No Encryption Connectorized 4900 5925 MHz 5 10 15 20 30 40 MHz 27 dBm Integrated 16 dBi 90 degree Table 18 PMP PTP 450b Series variants Frequency Variant Variant Antenna Frequency Range Channel Bandwidth Max Conducte...

Страница 48: ...8 dBi integrated 4900 5925 MHz 5 10 15 20 30 40 MHz 27 dBm Note The Transmit power is limited based on regional setting Table 21 PMP 450 Series variants Variant Region Antenna Frequency Range Channel Bandwidth Max Tx Power 900 MHz PMP 450 SM FCC Connectorized 902 928 MHz 5 7 10 15 20 MHz 25 dBm 2 4 GHz PMP 450 AP FCC ISM Connectorized 2400 2483 5 MHz 5 10 15 20 MHz 22 dBm Integrated 18 dBi 2 4 GHz...

Страница 49: ...5 MHz 5 10 15 20 30 40 MHz 5 15 and 30 MHz not available in DFS regions 22 dBm Integrated 9 dBi Integrated 25 dBi Note The Transmit power is limited based on regional setting Backhaul PTP The Backhaul radio is a transceiver device It is a connectorized or integrated outdoor unit containing all the radio networking and surge suppression electronics It can be configured as l Backhaul Master BHM l Ba...

Страница 50: ...ion Antenna Frequency Range Channel Bandwidth Max Tx Power Notes 3 GHz PTP 450b FCC RoW Canada Row DES Europe 20 dBi Dish antenna 3300 3900 MHz 5 7 10 15 20 30 40 MHz 29 dBm Transmit power limited based on regional setting 5 GHz PTP 450b FCC RoW Canada Row DES Europe Integrated 16 dBi 4900 5925 MHz 5 10 15 20 30 40 MHz 27 dBm Transmit power limited based on regional setting 23 dBi Dish antenna Tab...

Страница 51: ... 22 dBm Integrated 9 dBi Integrated 25 dBi Note The Transmit power is limited based on regional setting Table 25 PTP 450b Retro Series variants Variant Region Antenna Frequency Range Channel Bandwidth Max Tx Power 5 GHz PTP 450b Retro BH FCC RoW Canada RoW no encryption Europe Integrated 8 dBi 4900 5925 MHz 5 10 15 20 30 40 MHz 27 dBm 450 Plat form Family int erfaces PMP 450 m Series interfaces AP...

Страница 52: ...se T Ethernet plus Cambium Sync over data CAT 5e AUX 10 100Base T Ethernet with PoE out CAT 5e UGPS synchronization port Audio tones SFP 1 SFP module Currently not used when operating a 3 GHz 450m as an AP For future use when operating 3 GHz 450m as an LTE RRH Fibre or copper SFP 2 SFP module single or dual This is the module currently used for 3 GHz 450m AP Fibre or copper Ground Lugs For groundi...

Страница 53: ...Chapter 2 System hardware 53 PMP 450 m Series interfaces AP 5 GHz The 5 GHz 450m Series AP interfaces is illustrated below ...

Страница 54: ...MM5 sync over power synchronization input RJ45 Cable See Main port pinout Aux Sync GPS synchronization input and output UGPS power output RJ 45 Cable SeeAux port pinout Audio tones Data SFP Read Ethernet communications management and data Ground Lugs For grounding the unit 10 AWG copper wire Note For PMP 450m AP the Sync Over Power is supported with CMM5 only For PMP 450m AP the Sync Over Power wi...

Страница 55: ...AP SM BH The AP SM BH interfaces are illustrated below Figure 5 PMP PTP 450i interfaces Table 28 PMP PTP 450i Series AP SM BH interface descriptions and cabling Interface Function Cabling PSU Ethernet Power over Ethernet Ethernet communications management and data CMM sync over power synchronization input RJ45 Cable See Main port pinout Aux Sync GPS synchronization input and output UGPS power outp...

Страница 56: ...N type Ground Lugs For grounding the unit 10 AWG copper wire Note If the Aux port will be used a second Ethernet Gland will need to be ordered Part Number N000065L033A PMP PTP 450 b Mid Gain Series interfaces SM The PMP PTP 450b Series SM interfaces are illustrated below Figure 6 PMP 450b Mid Gain Series SM interfaces ...

Страница 57: ...e interfaces are accessible from the rear of the dish and are located under the cover shown Figure 7 450b Series interfaces High Gain Table 30 PMP PTP 450b Series High Gain interface descriptions and cabling Interface Function Cabling PSU Ethernet Power over Ethernet Ethernet communications management and data RJ45 Cable AUX Port 3 5 mm audio jack for alignment tone and synchronization Standard 3 ...

Страница 58: ...ment and data RJ45 Cable Sync Default GPS synchronization signaling provides power to UGPS module Default plug port RJ11 cable default plug RF Port A 2 4 GHz 45 degree RF connection to AP antenna 50 ohms RF cable N type 5 GHz Vertical RF connection to AP antenna RF Port B 2 4 GHz 45 degree RF connection to AP antenna 50 ohms RF cable N type 5 GHz Horizontal RF connection to AP antenna Ground Lugs ...

Страница 59: ... hardware 59 Figure 9 PMP PTP 450 Series SM BH interfaces Figure 10 PMP PTP 450 Series SM BH Connectorized interfaces Note As per Underwriters Laboratory UL guidelines the Ground Lug on the radiated SM is not required ...

Страница 60: ...Chapter 2 System hardware 60 Figure 11 PMP 450d Series SM Integrated Dish Figure 12 PMP 450 Series SM 3 GHz Integrated Figure 13 PTP 450 Series BHM BHS ...

Страница 61: ... to 4940 MHz to 5850 MHz l The maximum EIRP generated by ODU is restricted to comply with the ATEX and HAZLOC standards In order to meet specific radio regulations in the USA Canada and the EU Cambium supplies products approved for USA Canada EU and the rest of the world under different models and part numbers These models and part numbers are shown in PMP 450i Integrated ODU models part numbers a...

Страница 62: ...ame Connector Interface Description PSU Ethernet Port RJ45 PoE Input Power over Ethernet PoE 10 100 1000 BASE T Ethernet Data Reset button Push button Short press Reboot the device Long press Recovery mode Sector interface The PMP 450 MicroPoP Series Sector AP interfaces are illustrated below ...

Страница 63: ...oE Input Power over Ethernet PoE 10 100 1000 BASE T Ethernet Data Reset button Push button Short press Reboot the device Long press Recovery mode Diagnost ic LEDs The diagnostic LEDs of 450 Platform Family ODUs are as shown below Note The colors shown in the diagram may differ from the actual color displayed by the AP BHM depending on its current status ...

Страница 64: ...YN 1 PWR PMP PTP 450i Series AP BHM MAIN LNK 5 ACT 4 GPS 3 SES 2 SYN 1 PWR PMP PTP 450 Series AP BHM MAIN LNK 5 ACT 4 GPS 3 SES 2 SYN 1 PWR Table 36 450m 450i 450 AP BHM LED descriptions LED Color when active Status information provided Notes PWR Red DC power Always lit after 10 20 seconds of power on SYN 1 Yellow Presence of sync SES 2 Green Unused GPS 3 Red Pulse of sync Lit when the AP BHM is g...

Страница 65: ...n link is present Indicates speed based on the following colors 10BASE T Red 100BASE T Green 1000BASE T Orange For 450 AP Orange Green Yellow 10 100 1000 Ethernet link Continuously lit when link is present 10BASE T Orange 100BASE T Green 1000BASE T Yellow For 450 BHM Green Continuously lit when link is present 10BASE T Green 100BASE T Green MAIN LNK ACT 5 For 450m Series Red Green Orange bi colore...

Страница 66: ...it after power on ETH Red Green Orange Flashes in presence of data activity on the Ethernet link 10BASE T Red 100BASE T Green 1000BASE T Orange SES SYN Yellow Green Sync status Generating sync Yellow Receiving sync Green Solid Unit transmitting Blinking Unit synchronized but not transmitting SM BHS LEDs The SM BHS LEDs provide different status of radio based on the operating modes A SM BHS in oper...

Страница 67: ...K 5 ACT 4 GPS 3 SES 2 SYN 1 PWR PMP PTP 450b Mid Gain Series SM BHS ETH GPS SES SYNC POWER PMP PTP 450b 5 GHz High Gain Series SM BHS ETH GPS SES SYNC POWER PMP PTP 450 Series SM BHS MAIN LNK 5 ACT 4 GPS 3 SES 2 SYN 1 PWR PMP PTP 450b 3 GHz High Gain Series SM BHS ...

Страница 68: ...as been removed to show the location of the LEDs Table 40 450i 450 SM BHS LED descriptions Status information provided LED Color when active SM BHS in Operating Mode SM BHS in Aiming Mode Note PWR Red DC power Always lit after 10 20 seconds of power on SYN 1 Yellow Presence of sync These three LEDs act as a bar graph to indicate the relative quality of alignment As power level improves during alig...

Страница 69: ...E T Orange For 450 Series Green Ethernet link Continuously lit when link is present Table 41 5 GHz 450b SM BHS LED descriptions Status information provided LED Color when active SM BHS in Operating Mode SM BHS in Aiming Mode Note POWER Blue DC power Flashes Yellow during boot up Flashes Blue when operating Always lit after 10 20 seconds of power on SYNC Green Presence of sync These three LEDs act ...

Страница 70: ...ctive SM BHS in Operating Mode SM BHS in Aiming Mode Note PWR Blue DC power Always lit after power on ETH Red Green Orange 10 100 1000 Ethernet Link Flashes during data transfer Frequency of flash is not a diagnostic indication 10Base T Red 100BASE T Green 1000BASE T Orange SES SYN Yellow Green Session status Scanning Blinking yellow Registering Solid yellow Registered Solid green This LED indicat...

Страница 71: ...te PWR Blue DC power Always lit after power on ETH Red Green Orange 10 100 1000 Ethernet Link Flashes during data transfer Frequency of flash is not a diagnostic indication 10BASE T Red 100BASE T Green 1000BASE T Orange SES SYN Green Yellow Session status Scanning Blinking green This LED indicates when the signal level is sufficient for normal operation When the power rises above this threshold th...

Страница 72: ...o For 450m AP the MAIN LNK ACT 5 LED flashes to indicate data transfer speed and activity on the Main port and the AUX LNK ACT 4 LED flashes to indicate data transfer speed and activity on the Aux port o For 450 450i AP BHM the ACT 4 LED flashes during data transfer o For 450 450i SM BHS the ACT 4 LED flashes during data transfer o For 450b 3 GHz and 5 GHz the ETH LED flashes during data transfer ...

Страница 73: ...nected to the ODU and network terminating equipment using Cat 5e cable with RJ45 connectors Model 30 V DC 56 V DC 802 3af 802 3at N000900L001B C Gigabit 15W N000900L002A 100 Base T 15W obsolete N000000L034A AC 30W 56VDC N000065L001C AC 60W C000065L002C AC DC 100W N000000L054B AC 54V 240W PMP 450 AP X X X PMP 450 SM X X X PTP 450 X X X PMP PTP 450b X X X PMP 450i AP X X X X X PMP 450i SM X X X X X ...

Страница 74: ... Enhanced Power Injector l Power over Ethernet midspan 60 W 48 V DC Input l CMM4 with external 56 V power supply and CMM4 to 450i Series ODU cable Dongle l CMM5 56 V power and sync injector module with external 240 W or 600 W power supply l IEEE802 3at power injector Note The 900 MHz SM is based off of the 450 Series please see Power supply PMP PTP 450 Series Warning Always use an appropriately ra...

Страница 75: ...net midspan 60 W 48 V DC Input N000000L036A Power supply 30 W 56 V Gbps support N000000L034A AC Power Injector N0 0 0 0 65L0 0 1B The AC Power Injector interfaces are shown in AC Power Injector interfaces and described in AC Power Injector interface functions Figure 16 AC Power Injector interfaces Table 46 AC Power Injector interface functions Interface Function AC power in AC power input main sup...

Страница 76: ...17 AC DC Enhanced Power Injector interfaces Table 47 AC DC Enhanced Power Injector interface functions Interface Function 100 240V 47 63Hz 1 7A AC power input main supply DC In Alternative DC power supply input DC Out DC power output to a second PSU for power supply redundancy or to a NIDU ODU RJ45 socket for connecting Cat5e cable to ODU LAN RJ45 socket for connecting Cat5e cable to network Power...

Страница 77: ...and PTP 700 families only It does not operate with the 450 platform products Note The earlier power injector models only had a single power LED that combined the AC DC indications 48 V DC Power Injector N0 0 0 0 0 0 L0 36A The DC Power Injector interfaces are shown in 48 V DC Power Injector interfaces and described in 48 V DC Power Injector interfaces Figure 18 48 V DC Power Injector interfaces ...

Страница 78: ...Ds Two AC and Port Power supply PMP PTP 450 b Series The PMP PTP 450b Series support powering from the following powering sources l Gigabit Ethernet Capable Power Supply 20 to 32 V DC 15 W l CMM4 with external 29 V power supply l CMM5 29 V power and sync injector module with external 240 W or 600 W power supply Figure 19 20 to 32 V DC Power Injector interfaces ...

Страница 79: ...encapsulated in a 450i type enclosure contains 450 circuitry which must be powered via 30 V DC Powering these SMs with a 56 V DC will damage the device PSU part numbers Table 51 PSU part numbers for PMP PTP 450 Series Cambium description Cambium part number Gigabit Enet Capable Power Supply 30 V DC 15 W N000900L001C Cable UL Power Supply Cord Set US N000900L007A Cable UL Power Supply Cord Set EU N...

Страница 80: ...from the following powering sources l Power Supply 15 W or 30 W 56 V with 1000BASE T or GigE l AC DC Enhanced Power Injector l Power over Ethernet midspan 60 W 48 V DC Input l CMM4 with external 56 V power supply and CMM4 to 450i Series ODU cable Dongle l CMM5 56V power and sync injector module with external 240 W or 600 W power supply l IEEE802 3at power injector PSU part numbers Table 53 PSU par...

Страница 81: ...AC Power Injector interfaces Table 54 AC Power Injector interface functions Interface Function AC power in AC power input main supply ODU RJ45 socket for connecting Cat5e cable to ODU LAN RJ45 socket for connecting Cat5e cable to network Power green LED Power supply detection ODU mounting brackets accessories The list of supported brackets is provided in Accessories part numbers l The Tilt bracket...

Страница 82: ...5L036A Lightning protection The 450 Platform Family supports the lightning protection units listed in below table The LPU offers the highest level of protection and is the recommended device Where low cost deployment is essential for example for SM in residential application the Gigabit Surge Suppressor may be used instead Table 56 Lightning protection part numbers Model 30 V DC 56 V DC C000000L06...

Страница 83: ...L114 A DC Lightning Protection Unit kit PTP 450i X X X 5 GHz PMP 450m AP X X 3 GHz PMP 450m AP X PMP 450 MicroPo P X X X Cambium Networks does NOT recommend deploying Gas Discharge Tube based surge protection on PMP 450i PMP 450b or PMP 450 MicroPoP platforms ODU interfaces PMP 450 m Series 5 GHz AP These interfaces are described in PMP PTP 450i Series ODU rear interfaces Figure 22 PMP 450m Series...

Страница 84: ...E T Ethernet Data PoE output Standard IEEE802 3at PoE Sync input output Connection and powering of UGPS Sync input SFP SFP 2 5 Gbps Fiber Ethernet and 1 Gbps Copper Data and Management Services Plug in SFP module must be purchased separately Ground Lugs 10 AWG copper wire For grounding the unit PMP 450 m Series 3 GHz AP These interfaces are described in ODU interfaces Figure 23 PMP 450m 3 GHz AP r...

Страница 85: ...00BASE T Ethernet with PoE out Synchronization UGPS synchronization port Alignment Audio tones SFP 1 SFP Ethernet SFP module SFP 2 SFP Ethernet SFP module single or dual Ground Lugs 10 AWG copper wire For grounding the unit PMP PTP 450 i The Ethernet and Sync Aux ports are on the rear of the integrated and connectorized ODUs PMP PTP 450i Series ODU rear interfaces These interfaces are described in...

Страница 86: ...Data Sync Aux RJ45 10 100 1000BASE T Ethernet Data see Note below PoE output Standard IEEE802 3at PoE Sync input output Connection and powering of UGPS Sync input The front of the connectorized ODU PMP PTP 450i Series Connectorized ODU antenna interfaces provides N type female connectors for RF cable interfaces to antennas with ports A and B for vertical and horizontal polarization respectively ...

Страница 87: ...must be powered via 30 V DC Powering these SMs with a 48 V DC will damage the device Figure 25 PMP PTP 450i Series Connectorized ODU antenna interfaces PMP PTP 450 b Mid Gain High Gain Ret ro Int erfaces The Ethernet and Aux ports are on the rear of the integrated ODUs PMP PTP 450b Mid Gain High Gain ODU rear interfaces covers removed These interfaces are described in PMP PTP 450b Mid Gain High Ga...

Страница 88: ...GHz 450b Mid Gain 5 GHz 450b High Gain 3 GHz 450b High Gain 450b High Gain connections are located below cover behind the dish PMP PTP 450b Retro Table 60 PMP PTP 450b Mid Gain High Gain Retro ODU interfaces Port name Connector Interface Description PSU Ethernet RJ45 PoE input Power over Ethernet PoE 30 V DC ...

Страница 89: ...lse UGPS Aux Port Can also be configured to provide sync out when in BHM BHS SM modes cnPulse UGPS can also be powered from the 450b Aux port Note 1 GUI option Sync Aux Port Configuration controls the behavior of the Aux port Note 2 Pin out detail for Aux port Tip Alignment Tone Default GPS Sync 1PPS IN cnPulse or GPS Sync 1PPS Out Remote AP Ring 1 cnPulse 5 V Power Out Alignment Tone Stereo Out R...

Страница 90: ...in orange trace The 2 125 mast is at 270 degrees and you are looking top down onto the mast The orange pattern has major ripple due to the mast being beside the omni antenna and causing reflections If the lightning rod diameter is smaller such as 0 3 to 0 625 5 8 inches maximum then the omni pattern is not effected ripple is no worse than the base line plastic mast that is the light blue and blue ...

Страница 91: ...ersion or having a dissipator on top the dissipator concept has many smaller rods clustered together so they have many weak streamers instead of one large streamer which would attract a lighting hit better Below is a recommended example from the LBA Group 5 feet long 5 8 O D model DAT 160SS It is mandatory to have the mast grounded if this is not possible a 6 8 AWG Cu ground wire needs to attach t...

Страница 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical ...

Страница 93: ...450b AUX port Note Aux port can also be configured to provide Sync out Cambium Networks provide a 3 meter accessory cable N000000127A which operates with cnPulse only If a longer cable is desired please source a shielded outdoor 4 core cable and wire according to the table below Table 62 Connections for cnPulse to 450b Aux port cnPulse RJ45 pin 450b 3 5 mm TRRS jack Signal description 4 Ring 1 GPS...

Страница 94: ...th m ft Power supply PoE powered device on AUX SYNC port From power supply to ODU From ODU to PoE device on AUX SYNC port Power supply 30 W None 100 m N A IEEE 802 3at Type 2 Not supported AC Power Injector 60 W None 100 m N A IEEE 802 3at Type 2 100 m in total AC DC enhanced Power Injector None 100 m N A IEEE 802 3at Type 2 100 m in total 48 V DC power injector None 100 m N A IEEE 802 3at Type 2 ...

Страница 95: ...n and contraction and to facilitate terminating the cable again when needed l Include a drip loop to shed water so that most of the water does not reach the connector at the device l Properly crimp all connectors l Use dielectric grease on all connectors to resist corrosion Order Superior Essex type BBDGe cable from Cambium Networks Drop cable part numbers Other lengths of this cable are available...

Страница 96: ...ladding microns Mode Bandwidth at 1310 nm MHz km Maximum length of optical interface Insertion loss dB 62 5 125 Multi 500 550 m 1800 ft 1 67 50 125 Multi 400 550 m 1800 ft 0 07 50 125 Multi 500 550 m 1800 ft 1 19 10 125 Single N A 5000 m 16400 ft 0 16 Table 68 Multi mode Optical SFP Interface per ODU part number C000065L009 Core cladding microns Mode Bandwidth at 850 nm MHz km Maximum length of op...

Страница 97: ... pinout diagram for Main port is given below Table 69 Main port PoE cable pinout RJ45 pin Interface Ethernet description PoE input description 1 1000 BaseT Ethernet with PoE In TxRx0 Ve or Ve 2 TxRx0 3 TxRx1 Ve or Ve 6 TxRx1 4 TxRx2 Ve or Ve 5 TxRx2 7 TxRx3 Ve or Ve 8 TxRx3 Note The PoE input on the Main port accepts any polarity ...

Страница 98: ...Ethernet gland will need to be ordered Part Number N000065L033A Aux port to alignment tone headset wiring A standard 32 ohms stereo headset can be connected to the Aux port to use the audio alignment tool The diagrams of the adapters for RJ45 and RJ12 are provided in Alignment Tone Cable and RJ12 Alignment Tone Cable respectively The recommended values for both resistors are 220 ohms 0 25 W Differ...

Страница 99: ...g part number Table 73 Alignment tone adapter third party product details Reference Product description BT 1277 Headset alignment cable RJ45 for the PMP PTP 450i Series products BT 0674 Headset alignment cable RJ12 for the PMP PTP 450 Series products RJ45 connectors and spare glands RJ45 connectors are required for plugging Cat 5e cables into ODUs LPUs PSUs and other devices Order RJ45 connectors ...

Страница 100: ...able 74 RJ45 connector and spare gland part numbers Cambium description Cambium part number Tyco AMP Mod Plug RJ45 100 pack WB3177 Tyco AMP Crimp Tool WB3211 RJ45 Spare Grounding Gland PG16 size Qty 10 N000065L033 Breather Vent Breather vent is required for plugging into the spare ports of the ODUs Identify the spare port and remove the black sealing cap from the ODUs Install the breather vent scr...

Страница 101: ... looking towards the radio Test access can be made via any of the following l Directly onto the pins of the RJ45 plug l Using a commercially available RJ45 breakout board Measure between Approximate resistance Example Wire 1 and wire 2 Wire 3 and wire 6 Wire 4 and wire 5 Wire 7 and wire 8 1 ohm 2 ohms per 10 m of cable Maximum difference between any two readings 0 3 ohms 0 3 ohms per 10 m of cable...

Страница 102: ...e suppression for ODU installations Each cable requires two LPUs one near the ODU and the other near the linked device usually at the building entry point LPU and grounding kit contents Table 76 LPU and grounding kit contents Lightning protection units LPUs LPU grounding point nuts and washers ODU to top LPU drop cable 600 mm EMC strain relief cable glands U bolts nuts and washers for mounting LPU...

Страница 103: ...5L007B When using LPUs on the Ethernet Ports of the 3 GHz 450m a separate PoE power supply must be used at the bottom of the mast to forward bias the diodes in the LPUs This should be placed in the same position as used in a PoE Ethernet Port If this is not done CRC errors will occur on the Ethernet interface DC LPU and Grounding Kit 450m 3 GHz LPUs provide transient voltage surge suppression for ...

Страница 104: ... U bolts nuts and washers for mounting LPUs ODU to top LPU ground cable M6 M6 bolt and washers ODU to grounding system ground cable bottom LPU ground cable 2pcs M6 and M10 lugs bolt and washers 4 pin connector kits 4 kits one shown ...

Страница 105: ...y device one additional LPU and grounding kit is required for the Aux drop cable Order the kits from Cambium Network DC LPU and grounding kit part number Note When installing LPUs use only EMC cable glands supplied in the ODU and LPU kits with black caps Do not use the non EMC cable glands supplied in other kits with silver caps as these may only be used in ODU installations without LPUs ...

Страница 106: ...t One grounding kit Cable grounding kit is required for each grounding point on the cable Order cable grounding kits from Cambium Networks LPU and grounding kit part number Figure 38 Cable grounding kit Table 80 Cable grounding kit part numbers Cambium description Cambium part number Cable Grounding Kits For 1 4 And 3 8 Cable 01010419001 Antennas and antenna cabling Ant enna requirement s Each con...

Страница 107: ...i Series BH or PMP 450 450i Series SM external antenna Cambium description Cambium part number 900 MHz 12 dBi gain directional antenna Dual Slant N009045D003A RF cable and connect ors RF cable of generic type LMR 400 is required for connecting the ODU to the antenna N type male connectors are required for connecting the RF cables to the connectorized ODU Two connectors are required per ODU Use wea...

Страница 108: ...k s own self interference The Cluster Management CMM provides Global Positioning System GPS synchronization to the Access Point AP and all associated Subscriber Modules SM Network operators have a choice of UGPS and CMM solutions to select the option that works best for the environment Universal GPS UGPS The UGPS provides network synchronization for smaller networks where a CMM may not be cost eff...

Страница 109: ... optional AC DC power supplies are available from Cambium Networks l Uses Cambium Networks UGPS for a synchronization source l Dual resilient power inputs l Rack mountable l Secure remote management when used with the optional CMM5 Controller Module l Support for PMP 450m cnMedusa l Future support for integration into cnMedusa for cloud or NOC based management It consists of four subsystems descri...

Страница 110: ...t Scenario 2 The following is a CMM5 Cluster Management scenario using four PMP 450i Access Points and four PMP 450 Access Points Table 85 CMM5 Cluster Management Scenario 2 Scenario Equipment Needed Features Four PMP 450i Access Points Four PMP 450 Access Points l 56 Volt Injector l 29 Volt Injector l 1 CMM5 Controller l One UGPS l Gigabit Ethernet support l Local Management Interface l 48 V DC I...

Страница 111: ... Resilience required Secure Remote Management https Scalable to 32 devices Figure 41 Cluster Management Scenario 2 CMM5 Cont roller Module The major features of the CMM5 Controller Module are l Auto detect control up to 8 Power Injectors l Monitor SYNC Power GPS status l Manage up down ports l Web HTTPS and SNMPv2 v3 management SNMP on roadmap l 1U half width rack mount Figure 42 Controller Module...

Страница 112: ...r for the types of radios that you will be powering In both cases the injectors use the same input power supplies or can be powered with 48 V DC The output power is different and the type of SYNC signal used is different between the two types of injectors Systems can have 29 V and 56 V injectors deployed alongside each other Figure 43 Injector Module CMM5 Inject or Compat ibilit y Mat rix The foll...

Страница 113: ... Chain port OUT Surge Suppression Lightning Suppression for each To Radios RJ45 Port Power Input Voltage or 48 V DC Input Power Consumption 400 watts Output Voltage or 55 V DC Output Current 0 1 8 A per channel Output Power 0 90 Watts per channel Cabinet Temperature 40 C to 55 C 40 F to 131 F 90 humidity condensing Physical Max Distance from Managed Radios 328 cable feet 100m Max Distance to GPS A...

Страница 114: ...ck Mount The CMM4 has two DC power inputs one 29 V and one 56 V It can be used to power and synchronize both 29 V legacy products such as the PMP 450 Series and 56V products such as the PMP 450i Series simultaneously If the 29 V legacy products are connected to the CMM4 a 29 V power supply needs to be connected If the 450i Series is connected to the CMM4 a 56 V power supply needs to be connected T...

Страница 115: ...System hardware 115 Figure 45 CMM4 56 V power adapter dongle CMM4 56 V power adapter cable pinout Figure 46 CMM4 power adapter cabling diagram Table 88 CMM4 power adapter cable pinout Plug J1 pin Jack J2 pin 1 1 ...

Страница 116: ...oadband service the PMP PTP system gracefully scales to support large deployments The cluster management module is the heart of the system s synchronization capability which allows network operators to re use frequencies and add capacity while ensuring consistency in the quality of service to customers As a result subscribers can experience carrier grade service even at the outer edge of the netwo...

Страница 117: ...tiate Alternatively these parameters are settable A CMM3 requires only one cable terminating in an RJ45 connector for each connected module to distribute l Ethernet signaling l power to as many as 8 co located modules APs BHMs or BHSs Through a browser interface to the managed switch ports can be powered or not l sync to APs and BHMs The CMM3 receives 1 pulse per second timing information from Glo...

Страница 118: ...at meets the following requirements l It must be possible to protect the installation as described in Grounding and lightning protection l It must have an un interrupted view of at least half of the southern resp northern sky in the northern resp southern hemisphere For a receiver mounted on a wall there must be no other significant obstructions in the view of the sky l It must be mounted at least...

Страница 119: ...wer or mast GPS receiver tower or mast installation select a position that meets the following requirements l It must not be mounted any higher than is necessary to receive an adequate signal from four GPS satellites l It must be protected by a nearby lightning air terminal that projects farther out from the tower than the GPS receiver module Mount ing t he GPS receiver Mount the GPS receiver foll...

Страница 120: ...ntenna Please refer to the PMP Synchronization Solutions User Guide located on the Cambium website http www cambiumnetworks com resource pmp synchronization solutions Inst alling and connect ing t he GPS LPU Install and ground the GPS drop cable LPU at the building or cabinet entry point as described in Install the bottom LPU Ordering the components This section describes how to select components ...

Страница 121: ...0i Integrated High Gain Directional 5092JH 5092KH 450i Connectorized ATEX HAZLOC ATEX CONTROLLED ITEM 5085CHH 5085CJH 450i Integrated 90 Deg Sector ATEX HAZLOC ATEX CONTROLLED ITEM 5085HH 5085JH 450i Integrated High Gain Directional ATEX HAZLOC ATEX CONTROLLED ITEM 5095HH 5095JH PMP 450i AP Access Point 900 MHz PMP 450i Connectorized Access Point C009045A001A 3 GHz PMP 450i Connectorized Access Po...

Страница 122: ...MP 450i SM Integrated High Gain Antenna C030045C002A 5 GHz PMP 450i Connectorized Subscriber Module C050045C001A C050045C001B 5 GHz PMP 450i SM Integrated High Gain Antenna C050045C002A Previous model end April 2019 Revised model starts May 2019 Note The 450i SM does not have license keys Table 91 PMP 450i Integrated ODU models part numbers Cambium description Superseded Sales SKU Revised SKU suff...

Страница 123: ...Only ATEX HAZLOC C050045A019A C050045A019B 5 GHz PMP 450i Integrated Access Point 90 degree DES Only ATEX HAZLOC C050045A020A C050045A020B 5 GHz PMP 450i Conn Subscriber Module ATEX HAZLOC C050045C003A C050045C003B 5 GHz PMP 450i Integrated High Gain Antenna ATEX HAZLOC C050045C004A C050045C004B 5 GHz PMP 450i Integrated Access Point 90 degree ROW C050045A005B C050045A005C 5 GHz PMP 450i Integrate...

Страница 124: ...5 GHz PTP 450i END Connectorized RoW C050045B001A C050045B001B 5 GHz PTP 450i END Connectorized FCC C05004B003A C050045B003 5 GHz PTP 450i END Connectorized EU C050045B005A C050045B005B 5 GHz PTP 450i END Connectorized DES only C050045B007A C050045B007B 5 GHz PTP 450i END Connectorized IC C050045B015A C050045B015B 5 GHz PTP 450i END Integrated High Gain Antenna RoW C050045B002A C050045B002B 5 GHz ...

Страница 125: ... 450i END Integrated High Gain Antenna ROW ATEX HAZLOC C050045B010A C050045B010B 5 GHz PTP 450i END Connectorized FCC ATEX HAZLOC C050045B011A C050045B011B 5 GHz PTP 450i END Integrated High Gain Antenna FCC ATEX HAZLOC C050045B012A C050045B012B 5 GHz PTP 450i END Connectorized EU ATEX HAZLOC C050045B013A C050045B013B 5 GHz PTP 450i END Integrated High Gain Antenna EU ATEX HAZLOC C050045B014A C050...

Страница 126: ...n EU Radio Only C050045B024A 5 GHz 450b High Gain No Encryption Radio Only C050045B025A 5 GHz 450b 50 Mbps High Gain ROW Radio Only C050045B051A 5 GHz 4 Pack High Gain Antenna Assembly IP55 N050045D002A 3 GHz 450b High Gain Radio Only C030045B021A 3 GHz 450b High Gain No Encryption Radio Only C030045B025A 3 GHz High Gain Antenna Assembly IP55 4 pack N030045D001A 5 GHz 450b Retro ROW C050045B101A 5...

Страница 127: ...bscriber Module Uncapped C024045C004A 2 4 GHz PMP 450 Connectorized Subscriber Module 4 Mbps C024045C005A 2 4 GHz PMP 450 Connectorized Subscriber Module 10 Mbps C024045C006A 2 4 GHz PMP 450 Connectorized Subscriber Module 20 Mbps C024045C007A 2 4 GHz PMP 450 Connectorized Subscriber Module Uncapped C024045C008A 3 5 GHz PMP 450 High Gain Directional Integrated Subscriber C035045C014A 3 5 GHz PMP 4...

Страница 128: ...ectorized Subscriber Module 4 Mbps C054045C005B 5 GHz PMP 450 Connectorized Subscriber Module 10 Mbps C054045C006B 5 GHz PMP 450 Connectorized Subscriber Module 20 Mbps C054045C007B 5 GHz PMP 450 Connectorized Subscriber Module Uncapped C054045C008B 5 GHz PMP 450d Subscriber Module 20 Mbps 4 pack C054045H013B 5 GHz PMP 450d Subscriber Module Uncapped 4 pack C054045H014B PMP 450 MicroPoP Cambium de...

Страница 129: ...ted ROW DES Only C054045B003A PTP 450 5 GHz END Connectorized ROW DES Only C054045B004A PTP 450 5 GHz END Integrated FCC C054045B005A PTP 450 5 GHz END Connectorized FCC C054045B006A PMP PTP 450 450 i Series Accessories Table 97 PMP PTP 450 450i Series Accessories Cambium description Cambium part number PMP 450 AP Antenna Options 900 MHz 65 degree Sector Antenna Dual Slant N009045D001A 900 MHz 12 ...

Страница 130: ...6 V C000000L556B CMM5 Power Supply AC 54 V 240 W N000000L054B CMM5 Power Supply AC 48 V 600 W N000000L101A CMM5 Spare Controller Cable 1m N000000L102A CMM5 to UGPS Shielded Cable 20 meter N000000L103A CMM5 Spare DC Power Connector 10 pack N000000L104A CMM4 W RUGGEDIZED Switch and GPS 1090CKHH CMM4 NO Switch 1091HH CMM4 Rack Mount Assembly 1092HH Ethernet cable adapter for CMM4 N000045L001A cnPulse...

Страница 131: ...MP Mod Plug RJ45 100 pack WB3177 Tyco AMP Crimp Tool WB3211 RJ45 Spare Grounding Gland PG16 size Qty 10 N000065L033 DC LPU and Grounding Kit C000000L114A Cable assy Shielded 4C Stereo Plug 3 5mm TO RJ45 N000000L127A Mounting brackets Tilt Bracket Assembly N000045L002A Mounting Bracket Integrated N000065L031A Mounting Bracket Connectorized N000065L032A Upgrade Keys PMP 450 4 To 10 Mbps Upgrade Key ...

Страница 132: ...y 2 Additional Years SG00TS4017A PMP 450 Platform AP Extended Warranty 4 Additional Years SG00TS4025A PMP 450 Platform SM Extended Warranty 1 Additional Year SG00TS4010A PMP 450 Platform SM Extended Warranty 2 Additional Years SG00TS4018A PMP 450 Platform SM Extended Warranty 4 Additional Years SG00TS4026A ...

Страница 133: ...escribes factors to be taken into account when planning to use connectorized ODUs with external antennas in PMP PTP 450 Platform links l Data network planning describes factors to be considered when planning PMP PTP 450 Platform data networks l Network management planning describes how to plan for PMP PTP 450 Platform links to be managed remotely using SNMP l Security planning describes how to pla...

Страница 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation ...

Страница 135: ...Chapter 3 System planning 135 Figure 52 Wall installation ...

Страница 136: ...Chapter 3 System planning 136 Figure 53 Roof installation ...

Страница 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation ...

Страница 138: ...ecting a site for the ODU consider the following factors l Height and location to ensure that people are kept away from the antenna l Height and location to achieve the best radio path l Indoor location where the power supply LED indicators will be visible so the drop cable length will not exceed the maximum recommended length see Power supply site selection l Ability to meet the requirements spec...

Страница 139: ... feet 300m power cable Grounding and light ning prot ect ion Warning Electro magnetic discharge lightning damage is not covered under warranty The recommendations in this guide when followed correctly give the user the best protection from the harmful effects of EMD However 100 protection is neither implied nor possible Structures equipment and people must be protected against power surges typical...

Страница 140: ...ossibility of a direct strike Mount equipment in this zone Site grounding system Confirm that the site has a correctly installed grounding system on a common ground ring with access points for grounding the 450 Platform Family ODU If the outdoor equipment is to be installed on the roof of a high building Roof installation confirm that the following additional requirements are met l A grounding con...

Страница 141: ...ion as defined in EN 60950 1 if the operating ambient temperature may exceed 40 C including solar radiation l If the ambient temperature never exceeds 40 C the temperature of the external metal case parts of the ODU will not exceed the touch temperature limit of 70 C l If the ambient temperature never exceeds 60 C the temperature of the external metal case parts of the ODU will not exceed the touc...

Страница 142: ...formulae l Force in kilograms 0 1045aV2 where l a is the surface area in square meters and V is the wind speed in meters per second l Force in pounds 0 0042Av2 l where o A is the surface area in square feet and o v is the wind speed in miles per hour Applying these formulae to the 450 platform at different wind speeds the resulting wind loadings are shown in below tables Table 98 PMP 450m Series w...

Страница 143: ...r antenna 3 565 150 165 181 198 216 Table 101 PMP PTP 450i Series wind loading lb force Type of ODU Max surface area square feet Wind speed miles per hour 100 105 110 115 120 Connectorized 0 377 16 17 19 21 23 Directional antenna 5 GHz 1 001 42 46 51 56 61 Integrated 90º sector antenna 5 GHz 1 356 57 63 69 75 82 Directional Yagi antenna 900 MHz 0 27 11 13 14 15 16 External 65º sector antenna 900 M...

Страница 144: ... 375 423 474 528 585 Table 103 PMP PTP 450 Series wind loading lb force Type of ODU Max surface area square feet Wind speed miles per hour 100 105 110 115 120 External 60º sector antenna 2 4 GHz AP 2 9 122 134 147 161 175 External 60º sector antenna 5 GHz AP 0 71 29 8 33 37 39 43 External 90º sector antenna 5 GHz AP 0 89 37 41 45 49 54 SM 0 29 12 13 15 16 18 Integrated High Gain Ruggedized 1 42 46...

Страница 145: ...IIB C Ethylene 3 5 IIC B Hydrogen 2 IIC A Acetylene 2 Table 107 Further reading For information about Refer to Ordering Connectorized Integrated ATEX HAZLOC ODUs PMP 450i Integrated ODU models part numbers and PTP 450i Series Con ODU part numbers ATEX HAZLOC standards and type approval Hazardous location compliance in Legal and Open Source Guide Deployment of ATEX HAZLOC ODUs PMP PTP 450i Hazardou...

Страница 146: ... Light ning Prot ect ion Unit LPU locat ion Find a location for the bottom LPU that meets the following requirements l The bottom LPU can be connected to the drop cable from the ODU l The bottom LPU is within 600 mm 24 in of the point at which the drop cable enters the building enclosure or equipment room within a larger building l The bottom LPU can be bonded to the grounding system Radio Frequen...

Страница 147: ...yzing t he RF Environment An essential element in RF network planning is the analysis of spectrum usage and the strength of the signals that occupy the spectrum Regardless of how these parameters are measured and log or chart the results through the Spectrum Analyzer feature or by using a spectrum analyzer ensure measurements are performed l At various times of day l On various days of the week l ...

Страница 148: ...ocat ion Co location between OFDM 450 Series and FSK PMP PTP 1x0 The first step to avoid interference in wireless systems is to set all AP BHMs to receive timing from a synchronization source Cluster Management Module or Universal Global Positioning System This ensures that the modules are in sync and start transmitting at the same time each frame The second step to avoid interference is to config...

Страница 149: ...ultiple access points APs are deployed in the same geographical area it is important that they all transmit and receive at the same time If one AP transmits when another receives the AP that is receiving might not be able to correctly decode the signal coming from the subscriber modules SMs communicating with it because of the interfering signal coming from the other AP In order to avoid this type...

Страница 150: ...link signal Also in the time indicated with the orange arrow in below figure AP2 transmits when AP1 receives This may completely corrupt the reception of AP1 s uplink signal As indicated above LTE supports 5 ms and 10 ms frame lengths Cambium PMP devices support 2 5 ms and 5 ms frame length The only option for co locating LTE and Cambium PMP devices is for both systems to operate with a 5 ms frame...

Страница 151: ... its frame start shifted by an integer number of subframes The Cambium PMP frame always starts with the downlink portion of the frame followed by the turnaround time and then the uplink portion of the frame The LTE 10 ms interval however always starts with subframes D S and U as the first three subframes but it may have additional downlink subframes in the same frame For example in Frame Configura...

Страница 152: ...d with these parameters Figure X Example of APs that can be co located Figure Y Example of APs that cannot be co located Once the LTE Frame Configuration is selected from the drop down menu the LTE downlink and uplink times are defined The Cambium PMP frame times are determined by the following configuration parameters l Channel Bandwidth amount of spectrum allocated for communication in the secto...

Страница 153: ...er to help with the selection of system parameters Cambium Networks offers a PMP LTE co location tool available at https support cambiumnetworks com files colocationtool The PMP and LTE configuration parameters are entered in the spreadsheet and the frame structure for the two systems is displayed on the right side The tool checks that there is no overlap between one AP transmitting and the other ...

Страница 154: ...between one AP transmitting and the other receiving Mult iple OFDM Access Point Clust ers When deploying multiple AP clusters in a dense area consider aligning the clusters as shown below However this is only a recommendation An installation may dictate a different pattern of channel assignments Figure 57 Example layout of 16 Access Point sectors ABCD 90 degree sectors An example for assignment of...

Страница 155: ... 8 GHz 3 channel assignment by access site Symbol Frequency A 5 740 GHz B 5 760 GHz C 5 780 GHz Considerat ions on back t o back frequency reuse Cambium Networks recommends using back to back ABAB frequency reuse as shown in Example layout of 16 Access Point sectors ABCD 90 degree sectors This means that a base site of four sectors can be created using two frequencies which works very well and hel...

Страница 156: ...idth is low Also the range ratio applies to the longest distance SM shorter distance SMs have a better range ratio This frequency reuse plan may not always give 256QAM for the longest distance SMs It is usually a good compromise between using more spectrum and guaranteed modulation rate Reflecting objects Reflection shows two diagrams of the same reflecting object Uplink interference demonstrates ...

Страница 157: ...uce the throughput when both sector 1 and sector 3 are carrying traffic Sector Antenna and cnMedusa Antenna show regions enumerated A B C and D We also need to consider objects of size 1 2 3 and 4 and define the areas where the objects may interfere l object size 1 a flat building face with a clear reflecting property from sector to AP l object size 2 random metalwork such as a wireless tower l ob...

Страница 158: ...Chapter 3 System planning 158 Figure 61 cnMedusa Antenna ...

Страница 159: ...ed at zero azimuth The middle diagram represents the scaling required to the top diagram to allow for differences in azimuth of the considered reflecting object The bottom diagram is the scaled version of the top diagram allowing for the dotted azimuth line in the middle diagram PMP 450m Series AP is based on Massive MU MIMO technology The 5 GHz 450m is a 14x14 MIMO system which allows simultaneou...

Страница 160: ...or best MU MIMO performance it is recommended that the 450m AP is mounted installed on a mast that is extremely rigid no movement and is vertical l LINKPlanner can be used to plan SMs across the AP antenna azimuth Link planning This section describes factors to be considered when planning links such as range obstacles path loss and throughput LINKPlanner is recommended Range and obst acles Calcula...

Страница 161: ...etrate walls or extensive trees and foliage Pat h loss Path loss is the amount of attenuation the radio signal undergoes between the two ends of the link The path loss is the sum of the attenuation of the path if there were no obstacles in the way Free Space Path Loss the attenuation caused by obstacles Excess Path Loss and a margin to allow for possible fading of the radio signal Fade Margin The ...

Страница 162: ...gnal and the strength that the receiver requires for maintaining a reliable link A higher fade margin is characteristic of a more reliable link Adapt ive modulat ion Adaptive modulation ensures that the highest throughput that can be achieved instantaneously will be obtained taking account of propagation and interference When the link has been installed web pages provide information about the link...

Страница 163: ... maximum transmit power will be calculated automatically by the unit Calculat ing RF cable lengt h 5 8 GHz FCC only The 5 8 GHz band FCC approval for the product is based on tests with a cable loss between the ODU and antenna of not less than 1 2 dB If cable loss is below 1 2 dB with a 1 3 m 4 ft diameter external antenna the connectorized 450 Platform Family may exceed the maximum radiated spurio...

Страница 164: ...ithin two minutes l have an assigned static IP address for example 169 254 1 5 on the 169 254 network W hen a DHCP server is not found To operate on a network a computer requires an IP address a subnet mask and possibly a gateway address Either a DHCP server automatically assigns this configuration information to a computer on a network or an operator must input these items When a computer is brou...

Страница 165: ...Server l NAT without DHCP NAT NAT isolates devices connected to the Ethernet wired side of a SM from being seen directly from the wireless side of the SM With NAT enabled the SM has an IP address for transport traffic separate from its address for management terminates transport traffic and allows you to assign a range of IP addresses to devices that are connected to the Ethernet wired side of the...

Страница 166: ...his IP address is for only management purposes For security you must either l Assign a non routable IP address l Assign a routable IP address only if a firewall is present to protect the module You assign an IP addresses to computers and network components by either static or dynamic IP addressing You will also assign the appropriate subnet mask and network gateway to each module Address Resolut i...

Страница 167: ...red l 10 0 0 0 10 255 255 255 l 172 16 0 0 172 31 255 255 l 192 168 0 0 192 168 255 255 Also the subnet mask and network gateway for each CMM4 can be assigned Translat ion bridging Optionally the AP can be configured to change the source MAC address in every packet it receives from its SMs to the MAC address of the SM BHS that bridged the packet before forwarding the packet toward the public netwo...

Страница 168: ...e routing ERIF in the 802 1Q header l Multicast pruning l Flooding unknown unicast frames in the downlink As an additional exception the AP BHM does not flood downward the unknown unicast frames to the SM BHS A VLAN configuration in Layer 2 establishes a logical group within the network Each computer in the VLAN regardless of initial or eventual physical location has access to the same data For th...

Страница 169: ...t modules Table 112 VLAN filters in point to multipoint modules Where VLAN is active if this parameter value is selected then a frame is discarded if because of this VLAN filter in the software entering the bridge NAT switch through Ethernet TCP IP any combination of VLAN parameter settings with a VID not in the membership table Ingress any combination of VLAN parameter settings with a VID not in ...

Страница 170: ...802 1ad Q in Q DVLAN Double VLAN tagging which is a way for an operator to put an 802 1Q VLAN inside of an 802 1ad VLAN A nested VLAN which is the original 802 1Q tag and a new second 802 1ad tag allows for bridging of VLAN traffic across a network and segregates the broadcast domains of 802 1Q VLANs Q in Q can be used with PPPoE and or NAT The 802 1ad standard defines the S VLAN as the Service Pr...

Страница 171: ...hispGPSInSync which signals a transition from not synchronized to synchronized l whispGPSOutSync which signals a transition from synchronized to not synchronized l whispRegComplete which signals registration completed l whispRegLost which signals registration lost l whispRadarDetected which signals that the one minute scan has been completed radar has been detected and the radio will shut down l w...

Страница 172: ...k AES Advanced Encryption Standard An over the air link encryption option that uses the Rijndael algorithm and 128 bit keys to establish a higher level of security than DES AES products are certified as compliant with the Federal Information Processing Standards FIPS 197 in the U S A The default encryption setting for 450 Platform Family ODU is None Planning for HTTPS operat ion Before starting to...

Страница 173: ...er Identify the format used for SNMP Engine ID The following formats are available l MAC address default l 5 and 32 hex characters the hex character input is driven by RFC 3411 recommendations on the Engine ID Identify the usernames and security roles of initial SNMPv3 users Two security roles are available l Read Only l System Administrator Identify the security level for each of the security rol...

Страница 174: ...ou are intent on configuring only one of them delete the admin account The root account is the only account that CNUT uses to update the module After a password has been set for any ADMINISTRATOR level account initial access to the module GUI opens the view of GUEST level Planning for RADIUS operat ion Configure RADIUS where remote authentication is required for users of the web based interface Re...

Страница 175: ... Enabled Where NAT is enabled on the SM BHS the filtering can be enabled for only the user defined ports The following are examples for situations where the configure port can be filtered where NAT is enabled l To block a subscriber from using FTP you can filter Ports 20 and 21 the FTP ports for both the TCP and UDP protocols l To block a subscriber from access to SNMP you can filter Ports 161 and...

Страница 176: ...cal protocol filtering The following are example situations in which the protocol filtering is configured where NAT is disabled l If a subscriber is blocked from only PPPoE and SNMP then the subscriber retains access to all other protocols and all ports l If PPPoE IPv4 and Uplink Broadcast are blocked and check the All others selection then only Address Resolution Protocol is not filtered The port...

Страница 177: ...fic destined to exit the FEC interface Port Configuration 450 Platform Family supports access to various communication protocols and only the ports required for these protocols are available for access by external entities Operators may change the port numbers for these protocols via the radio GUI or SNMP Table 115 Device default port numbers Port Usage Port Usage Device 21 FTP Listen Port AP SM 8...

Страница 178: ...vel switching It is not based on VLAN IDs Filt ering management t hrough Et hernet Configure the SM to disallow any device that is connected to its Ethernet port from accessing the IP address of the SM If the Ethernet Access Control parameter is set to Enabled then l No attempt to access the SM management interface by http SNMP ftp or tftp through Ethernet is granted l Any attempt to access the SM...

Страница 179: ...thing else apart from valid characters will be skipped Cont rolling PPPoE PADI Downlink Forwarding The AP supports the control of forwarding of PPPoE PADI PPPoE Active Discovery Initiation packets This forwarding is configured on the AP GUI Configuration Radio page by parameter PPPoE PADI Downlink Forwarding When set to Enabled the AP allows downstream and upstream transmission of PPPoE PADI packe...

Страница 180: ...ns not all frequencies are available l your deployments must be consistent with local regulatory restrictions Example Use Case for RF Obst ruct ions A remote AP can be used to provide last mile access to a community where RF obstructions prevent SMs from communicating with the higher level AP in cluster For example you may be able to use 900 MHz for the last mile between a remote AP and the outlyi...

Страница 181: ...ch SMs can be connected to which APs Devices PMP 450 AP BHM PMP 450i AP BHM PMP 450m AP PMP 450 SM BHS X PMP 450i SM BHS X X Examples of passing sync over cable are shown under Passing Sync in an Additional Hop For PMP 450 the sync is passed in a cable that connects Pins 1 and 6 of the RJ 11 timing ports of the two modules For PMP 450i 450m the sync is passed in a cable that connects Pins7 and 8 o...

Страница 182: ... a customer Figure 68 Remote AP wired to SM that also serves a customer If the SM simply serves as a relay you must use a straight through RJ 45 female to female coupler and wire the SM to the remote AP as shown in Remote AP wired to SM that serves as a relay ...

Страница 183: ...is BH timing master sends the sync over the air to a BH timing slave Passing Sync in an Additional Hop Network sync can be extended by one additional link in any of the following network designs Note In each of these following designs Link 2 is not on the same frequency band as Link 4 For example Link 2 may be a 5 2 GHz link while Link 4 is a 5 7 or 2 4 GHz link l Design 3 o A CMM provides sync to...

Страница 184: ...rs the sync to a co located BHM o This BHM passes the sync in the additional link over the air to a BHS This design is illustrated in Additional link to extend network sync Design 4 Figure 71 Additional link to extend network sync Design 4 l Design 5 o A CMM provides sync to a co located BHM or the BHM generates timing o This BHM sends the sync over the air to a BHS o This BHS delivers the sync to...

Страница 185: ...ted modules using a sync cable with RJ 11 for 450 or RJ 45 for 450i 450m connectors 2 Set the Sync Input parameter on the Configuration page of the co located AP or BH timing master to AutoSync 3 Set the Device Type parameter on the Configuration page of the co located AP or BH timing master to Remote 4 Set the Sync Output to Aux Port parameter on the Configuration page of the co located AP or BH ...

Страница 186: ...uld void the user s authority to operate the equipment and will void the manufacturer s warranty Attention Changements ou modifications Intentionnels ou non de l équipement ne doivent pas être entrepris sans l autorisation de l organisme responsable de la déclaration de conformité Ces modifications ou changements pourraient invalider le droit de l utilisateur à utiliser cet appareil et annuleraien...

Страница 187: ...zardous locat ions Warning When installing the PMP PTP 450i ATEX HAZLOC product variants in hazardous locations follow the instructions contained in the PMP PTP 450i Series Hazardous Location Guide supplied in box with the products in addition to the instructions in this user guide Sit ing of ODU and soundness of st ruct ure l Ensure that the Outdoor Unit ODU and the structure to which it is mount...

Страница 188: ...tenna l The units start to radiate RF energy as soon as they are powered up Grounding and light ning prot ect ion requirement s Structures equipment and people must be protected against electrostatic discharge l By siting ODU equipment in a lightning protection zone l ODUs external antennas and GPS receivers are not designed to survive direct lightning strikes For this reason they must be installe...

Страница 189: ... connection requirements for grounding electrodes Other regulations may apply in different countries and therefore it is recommended that installation of the outdoor unit be contracted to a professional installer Thermal Safet y The ODU enclosure may be hot to the touch when in operation The ODU must not be operated in ambient temperatures exceeding 40 C unless mounted in a Restricted Access Locat...

Страница 190: ...stem Ensure that all safety precautions are observed Preparing invent ory Perform the following inventory checks l Check that the correct components are available as described in Ordering the components on page 1 l Check the contents of all packages against their packing lists Preparing t ools Check that following specific tools are available in addition to general tools l RJ45 crimp tool it must ...

Страница 191: ...ng the Computing Device for Test If the computer is configured for Dynamic Host Configuration Protocol DHCP disconnect the computer from the network If the computer is instead configured for static IP addressing l Set the static address in the 169 254 network l Set the subnet mask to 255 255 0 0 For detailed instructions see section Configuring the management PC on page Configuring the management ...

Страница 192: ...s during data transfer Frequency of flash is not a diagnostic indication Table 116 3 GHz 450b BHM LED descriptions LED Color when active Status information provided Note POWER Blue DC power Always lit after power on ETH Red Green Orange Flashes in presence of data activity on the Ethernet link 10Base T Red 100Base T Green 1000Base T Orange SES SYN Yellow Green Sync status Generating sync Yellow Re...

Страница 193: ...to the pole l Alignment tone adapter headset Used for aligning the SM to the AP Universal Global Positioning System l Philips Screwdriver Used for attaching the UGPS unit to the pole mast mounting bracket l 13mm Spanner Wrench or Ratchet Spanner Wrench Used for connecting the mounting bracket s U bolt to the antenna or mast Cabling l Electrician s Scissors or Wire Cutters Used for cutting wire to ...

Страница 194: ... when needed l Include a drip loop to shed water so that most of the water does not reach the connector at the device l Properly crimp all connectors l Use dielectric grease on all connectors to resist corrosion l Use only shielded connectors to resist interference and corrosion W iring Connectors The following diagrams correlate pins to wire colors and illustrate crossovers where applicable Pin 1...

Страница 195: ... Alignment tone out GPS data out 5 GPS data in 6 TxRx1 7 GPS 0v 8 GPS Sync in RJ 45 Pinout for Straight through Ethernet Cable Figure 75 Straight through Ethernet Cable Table 120 RJ 45 pinout for straight through Ethernet cable Pin Signal Pair Color 1 TP1 2 White orange stripe 2 TP1 2 Orange solid 3 TP2 3 White green stripe 4 TP3 1 Blue solid 5 TP3 1 White blue stripe 6 TP2 3 Green solid ...

Страница 196: ...2 3 Green solid 3 TP2 3 White green stripe TP1 2 White orange stripe 4 TP3 1 White blue stripe TP4 4 White brown stripe 5 TP3 1 Blue solid TP4 4 Brown solid 6 TP2 3 Green solid TP1 2 Orange solid 7 TP4 4 White brown stripe TP3 1 Blue solid 8 TP4 4 Brown solid TP3 1 White blue stripe AP BHM to UGPS cable The AP BHM to UGPS cable can be constructed from RJ12 to RJ 45 cable using the pin configuratio...

Страница 197: ...ructed using RJ45 plug and Stereo plug The pin configuration is shown in Alignment tone cable pin configuration Figure 78 Alignment tone cable pin configuration For more information refer Aux port to alignment tone headset wiring Override plug cable for PMP 450 only To construct an override plug perform the following steps l Crimp an RJ 12 6 pins connector onto a 6 inch length of CAT 5 cable l Pin...

Страница 198: ...ernet jack of the computing device 4 Plug the power supply into an electrical outlet Warning From this point until you remove power from the ODU stay at least as far from the AP as the minimum separation distance specified 5 Power up the computing device 6 Start the browser in the computing device The AP BHM interface provides a series of web pages to configure and monitor the unit Access web base...

Страница 199: ...BH Procedure 4 Logging into the web interface 1 Plug one end of a CAT 5 Ethernet cable into the AP BHM 2 Plug the Ethernet cable connector labeled To Radio into the jack in the pig tail that hangs from the power supply 3 Plug the other connector of the pig tail this connector labeled To Computer into the Ethernet jack of the computing device 4 Plug the power supply into an electrical outlet Warnin...

Страница 200: ...iled installation procedures that are not included in the above topics such as how to strip cables create grounding points and weatherproof connectors Note These instructions assume that LPUs are being installed from the 450 Platform Family LPU and grounding kit Cambium part number C000065L007 If the installation does not require LPUs adapt these instructions as appropriate If LPUs are being insta...

Страница 201: ...ounting bracket which is supplied along with Yagi antenna Mount the ODU LPU and surge suppressor To install the ODU and top LPU use the following procedures l Attach ground cables to the ODU l Mount the ODU on the mast l Mount the top LPU l Mount the Surge Suppressor At t ach ground cables t o t he ODU PMP 450m Series AP 1 Fasten an AWG 10 or 6mm2 copper ground cable to each ODU grounding point us...

Страница 202: ...licable regulations PMP PTP 450 i Series AP SM BH PMP 450 3 GHz Ruggedized SM 1 Fasten an AWG 10 or 6mm2 copper ground cable to each ODU grounding point using the M6 small lugs 2 Tighten the Ground post screws 3 Securely connect the copper wires to the grounding system Protective Earth and the LPU or Gigabit Ethernet Surge Suppressor according to applicable regulations ...

Страница 203: ... Earth according to applicable regulations PMP 450 SM 1 Fasten an AWG 10 or 6mm2 copper ground cable to each ODU grounding point using the M6 small lugs 2 Tighten the Ground post locking nut in the copper wire 3 Securely connect the copper wire to the grounding system Protective Earth according to applicable regulations The grounding point on PMP 450 Series SM 900 MHz is different from 2 4 3 5 3 6...

Страница 204: ...er and lower brackets of ODU 3 Attach the upper and lower bracket of ODU to the mount point by closing the rear strap around the pole 4 Secure the four serrated flange M8 nuts by applying 10 Nm torque on upper and lower rear strap using a 13 mm spanner wrench These must be tightened evenly on the pole to avoid jumping stripping threads 5 Secure the bolts on four sides by applying 8 Nm torque as pe...

Страница 205: ...rs 5 Adjust the elevation and azimuth to achieve visual alignment PMP 450 b Mid Gain SM 1 Use a stainless steel hose clamp for the attachment 2 Attach the mounting bracket to the structure with the release tab facing downward Tighten the hose clamp 3 Slide the 450b SM onto the mounting bracket Press downwards until it clicks into place 4 Loosen the adjuster wingnut on the bracket and set the requi...

Страница 206: ... l 5mm Allen key l 13mm wrench l Torque wrench 1 Snap in the rear housing assembly 2 Insert screws to hold the rear housing assembly to the dish and tighten to a 10 Nm torque 3 Snap in the center feed tube radio to the assembly ...

Страница 207: ...hten to avoid damaging the feed tube 5 Assemble the pole bracket to the Rear housing bracket using the M8 bolts 6 Slide the cover onto the body of the radio ensuring that the two sliding rails engage with the slots in the dish body Attach and tighten the two cover screws to the body Tighten to 5 Nm torque ...

Страница 208: ...move outer clamp Slip clamp over pole and tighten M8 nuts by applying 8 Nm torque Do not over tighten to prevent aligning the dish After alignment ensure that the two bracket bolts and two pole clamp nuts are tightened to 25 Nm Fitting a synchronization cable to the aux port For PTP Backhaul Master applications requiring synchronization a synchronization cable may be fitted to the aux port as desc...

Страница 209: ...r door and locate the breakout 3 Use pincers to break out the piece of plastic and trim with a sharp blade Check that synchronization cable fits the opening 4 Assemble unit as in steps 1 to 8 above 5 Connect the synchronization cable to the rear 3 5 mm jack socket and replace the door ...

Страница 210: ...kit N00000L135A is required This kit contains 4 off IP67 door glands Follow the fitting instructions 1 5 in section PMP 450b High Gain IP55 Version above and then the steps below Note that a permanent connection to the AUX port is not available when using this kit 1 Locate an IP67 door gland from kit N00000L135A 2 Remove the cable gland from bottom cover Feed the RJ45 cable though the gland bottom...

Страница 211: ... the radio 5 On the pole bracket loosen the M8 nuts to remove outer clamp Slip clamp over pole and tighten M8 nuts by applying 8 Nm torque Do not over tighten to prevent aligning the dish After alignment ensure that the two bracket bolts and two pole clamp nuts are tightened to 25 Nm PMP 450 MicroPoP Omni 1 Assemble the pole mounting bracket to the radio with two screws ...

Страница 212: ...5 Installation 212 2 Secure pole mounting bracket to the radio with M8 nut and bolt by applying 3 0 Nm torque 3 Insert hose clamps through the pole mounting bracket and attach to pole by applying 3 0 Nm torque ...

Страница 213: ...on 213 4 Remove the cable gland from bottom of the radio Feed the RJ45 cable though the gland bottom cover and connect to the radio PMP 450 MicroPoP Sector 1 Assemble the pole mounting bracket to the radio with two screws ...

Страница 214: ...Chapter 5 Installation 214 2 Secure pole mounting bracket with M8 nut and bolt by applying 3 0 Nm torque 3 Insert hose clamps through pole mounting bracket and clamp to pole by applying 3 0 Nm torque ...

Страница 215: ...from bottom of the radio Feed the RJ45 cable though the gland bottom cover and connect to the radio 5 Align radio to required angle by tilting up and down The maximum radio tilting angle is 40 with an incremental of 10 Secure radio with max 5 0 Nm torque ...

Страница 216: ...o Pole Mount 1 Insert hose clamps on the device bracket and attach to the pole by applying 3 0 Nm torque 2 Release the bottom cap and insert RJ45 cable on the bottom of the device 3 Place the cap back on the device after the cable installation ...

Страница 217: ...Chapter 5 Installation 217 Dish Mount 1 Slide the device into the dish slot as shown in the below figure 2 Insert hose clamps on the device bracket and attach to the dish by applying 3 0 Nm torque ...

Страница 218: ...Chapter 5 Installation 218 3 Release the bottom cap and insert RJ45 cable on the bottom of the device 4 Place the cap back on the device after the cable installation ...

Страница 219: ...quantity and l M8 flat washers 2 quantity l M8 coil washers 2 quantity Attach the mounting bracket to the pole mast The mounting bracket is designed to attach to poles with diameters in the range of 2 in 50mm to 3in 75mm 3 Complete the AP mounting assembly by attaching the included l 8mm hex cap bolt one quantity Through the AP s attached mounting bracket and pole mount Now the AP may be adjusted ...

Страница 220: ... mounting procedure is different from other radios It does not get directly mounted on pole 1 Align the 900 MHz SM to E bracket of Yagi antenna 2 Slide the radio towards right to lock on the antenna Mount t he t op LPU 1 For separate LPU mounting use the U bolt bracket from the LPU kit to mount the top LPU on the pole below the ODU Tighten to a torque setting of 7 0 Nm 5 2 lb ft Please refer Gigab...

Страница 221: ...ck procedure for the Surge Suppressor for PMP PTP 450i 450b Series mounting is as follows 1 Ground using the terminal on the back of the units Use the supplied Tubular Lug and 6 mm2 10 AWG stranded cable max length 600 mm 24 l Waterproof the cable lug with heat shrink sleeving l Secure the Cable assembly to the unit using the supplied screw and washer 2 Mount the Gigabit Ethernet Surge Suppressor ...

Страница 222: ...Installation 222 4 Slide the end cap over the bottom of the Gigabit Ethernet Surge Suppressor ensuring it clicks firmly in place Refer to the Gigabit Ethernet Surge Suppressor Installation Guide for more details ...

Страница 223: ...rge Suppressor PMP PTP 450 Series The PMP PTP 450 Series uses 600SSH Surge Suppressor The inside of the surge suppressor is shown in Installation Caution The PMP 450 SM 900 MHz is based off of the 450 Series be sure to use a 600SS to protect this radio type ...

Страница 224: ...le Opening route the 10 AWG 6 mm2 ground cable through this opening 5 CAT 5 Cable Knockouts route the two CAT 5 cables through these openings or alternatively through the Conduit Knockouts 6 Conduit Knockouts on the back of the case near the bottom Available for installations where cable is routed through building conduit Note The 600SSH surge suppressor is shipped in the isolated position pin 4 i...

Страница 225: ... the 600SSH and to the power adapter 11 Replace the cover of the 600SSH General prot ect ion inst allat ion To adequately protect a 450 Platform Family installation both ground bonding and transient voltage surge suppression are required Grounding cable requirements When routing fastening and connecting grounding cables the following requirements must be implemented l Grounding conductors must be ...

Страница 226: ... Surge Suppressor should be kept to a minimum l The drop cable must not be laid alongside a lightning air terminal l All grounding cables must be a minimum size of 10 mm2 csa 8AWG preferably 16 mm2 csa 6AWG or 25 mm2 csa 4AWG Protection requirements for a wall installation If the ODU is to be mounted on the wall of a building then in addition to the general protection requirements above the follow...

Страница 227: ...l tower or mast then in addition to the general protection requirements above the following requirements must be observed l The equipment must be lower than the top of the tower or its lightning air terminal l The metal tower or mast must be correctly grounded Schematic examples of mast or tower installations are shown in Grounding and lightning protection on mast or tower ...

Страница 228: ...w the lightning terminals and finials l A grounding conductor must be installed around the roof perimeter to form the main roof perimeter lightning protection ring l Air terminals are typically installed along the length of the main roof perimeter lightning protection ring typically every 6 1m 20ft l The main roof perimeter lightning protection ring must contain at least two down conductors connec...

Страница 229: ...when power is applied to the PSU or network terminating equipment Caution Always use Cat5e cable that is gel filled and shielded with copper plated steel Alternative types of Cat5e cable are not supported by Cambium Networks Cambium Networks supply this cable Cambium part numbers WB3175 and WB3176 RJ45 connectors Cambium part number WB3177 and a crimp tool Cambium part number WB3211 The LPU and gr...

Страница 230: ...g a grip can cause the cable to slip break or fall l The minimum requirement is one hoisting grip for each 60 m 200 ft of cable Cut to length and fit hoisting grips 1 Cut the main drop cable to length from the top LPU to the bottom LPU 2 Slide one or more hoisting grips onto the top end of the drop cable 3 Secure the hoisting grip to the cable using a special tool as recommended by the manufacture...

Страница 231: ...n 4 Blue Blue 5 Light Blue White Blue 6 Green Green 7 Light Brown White Brown 8 Brown Brown Figure 88 RJ45 cable Inst all t he bot t om LPU t o PSU drop cable Install the bottom LPU Install the bottom LPU ground it and connect it to the main drop cable 1 Select a mounting point for the bottom LPU within 600 mm 24 in of the building entry point Mount the LPU vertically with cable glands facing down...

Страница 232: ...g the M10 large lug Install the LPU to PSU drop cable Use this procedure to terminate the bottom LPU to PSU drop cable with RJ45 connectors at both ends and with a cable gland at the LPU end Warning The metal screen of the drop cable is very sharp and may cause personal injury ALWAYS wear cut resistant gloves check the label to ensure they are cut resistant ALWAYS wear protective eyewear ALWAYS us...

Страница 233: ...connectorized ODU proceed as follows 1 Mount the antenna s according to manufacturer s instructions 2 Connect the ODU A and B interfaces to the antenna s with RF cable of type LMR 400 Cambium part numbers 30010194001 and 30010195001 and N type connectors Cambium part number 09010091001 Tighten the N type connectors to a torque setting of 1 7 Nm 1 3 lb ft 3 If the ODU is mounted indoors install lig...

Страница 234: ...hods Ensure that no undue strain is placed on the ODU or antenna connectors Ensure that the cables do not flap in the wind as flapping cables are prone to damage and induce unwanted vibrations in the supporting structure Note A video on weatherproofing procedure can be found at https www youtube com watch v a twPfCVq4A Assembling the PMP 450 i AP 5 GHz sector antenna and attaching to the radio To ...

Страница 235: ...ng the unit at the deployment site 1 Inventory the parts to ensure that you have them all before you begin The full set of parts is shown below Figure 89 AP antenna parts 2 Remove top plate from the antenna as shown in Antenna top plate Figure 90 Antenna top plate 3 Attach the antenna plate to the AP as shown in Attaching antenna plate to the AP ...

Страница 236: ...t Figure 91 Attaching antenna plate to the AP 4 Attach the plate mounted AP to the antenna and tighten the 4 serrated flange nuts using a spanner wrench Figure 92 Attaching the plate 5 Connect the port A of AP to vertical and port B of AP to horizontal polarization interfaces of the antenna with RF cable Tighten the N type connectors to a torque setting of 1 7 Nm 1 3 lb ft ...

Страница 237: ...e 2 7 hex bolts to the bracket using 2 serrated flange nuts Figure 94 AP antenna upper bracket assembly 7 Attach the upper bracket to the adjustment arms using 2 hex bolts 2 flat washers and 2 lock washers Feed the bolt through the lock washer then flat washer then thread the bolt into the upper bracket s threaded receptacle ...

Страница 238: ...errated flange nuts and 1 retaining bracket Do not tighten the nuts now Figure 96 Rear strap connected to upper AP antenna bracket 9 Attach the entire upper bracket to the antenna using 2 hex bolts 2 flat washers and 2 lock washers Feed the bolt through the lock washer then flat washer then thread the bolt into the upper bracket s threaded receptacle ...

Страница 239: ... to the bracket using 2 serrated flange nuts Figure 98 AP Antenna Lower Bracket Assembly 11 Attach the rear strap to the bracket using 2 serrated flange nuts and 1 retaining bracket Do not tighten the nuts now Attach the entire lower bracket to the antenna using 2 hex bolts 2 flat washers and 2 lock washers Figure 99 Lower bracket attached to AP antenna ...

Страница 240: ...um recommends assembling the antenna attach the AP and cabling and to seal the RF connections before installing the unit at the deployment site 1 Inventory the parts to ensure that you have them all before you begin The full set of parts is shown below Figure 101 PMP 450 AP antenna parts 2 Begin assembling the upper bracket by attaching the 2 7 hex bolts to the bracket using 2 serrated flange nuts...

Страница 241: ...at washers and 2 lock washers Feed the bolt through the lock washer then flat washer then thread the bolt into the upper bracket s threaded receptacle Figure 103 AP antenna upper bracket attached to upper adjustment arms 4 Attach the rear strap to the upper bracket using 2 serrated flange nuts and 1 retaining bracket Do not tighten the nuts now ...

Страница 242: ...105 Assembled upper bracket connected to AP antenna Note Use shielded cable for all infrastructure connections associated with APs SMs and CMMs The environment that these modules operate in often has significant unknown or varying RF energy Operator experience consistently indicates that the additional cost of shielded cables is more than compensated by predictable operation and reduced costs for ...

Страница 243: ...Lower bracket attached to AP antenna Attaching the PMP 450 AP to the antenna To attach a PMP 450 Series AP to the antenna perform the following steps Note Use shielded cable for all infrastructure connections associated with APs SMs and CMMs The environment that these modules operate in often has significant unknown or varying RF energy Operator experience consistently indicates that the additiona...

Страница 244: ... bracket to the rear of the AP 2 Attach the AP to the antenna by sliding the bracket onto the bolts and tighten the 4 serrated flange nuts using a 13 mm spanner wrench Figure 109 Lower bracket attached to AP antenna Note If using a non standard antenna do not cover the equilibrium membrane vent located on the back of the unit ...

Страница 245: ...ket of the antenna to the mount point by closing the rear strap around the pole and tightening the 2 serrated flange nuts using a 13mm spanner wrench These must be tightened evenly on the pol to avoid jumping stripping threads Figure 111 Attaching the AP antenna upper bracket to the pole 2 Attach the lower bracket of the antenna to the mount point by closing the rear strap around the pole ...

Страница 246: ...lan to allow at least 25 MHz of separation between their center channels 5 Secure a ground strap to the ground lug on the back of the AP 6 Secure the ground strap to the pole tower or other trusted ground 7 The bracket of the standard antenna has provision for measured down tilt The recommended practice is to use one of the many radio analysis and mapping tools or on line tools to calculate down t...

Страница 247: ...s A expressed in kilometers To use English standard units to find the angle of elevation use the following formula Where Is B expressed in feet A expressed in miles The angle of depression from the higher module is identical to the angle of elevation from the lower module 8 Connect the coax cables to the antenna and to the AP 9 Weatherproof the connector on the coax cables see section Attaching an...

Страница 248: ...Hz Mounting of PMP 450 i AP 90 0 MHz 1 Inventory the parts to ensure that you have them all before you begin The full set of parts is shown in Installation Figure 114 PMP 450i AP 900 MHz antenna unbox view Figure 115 PMP 450i AP 900 MHz antenna inventory ...

Страница 249: ... 1 Unfold the upper bracket assembly of the antenna 2 Unfold the lower bracket assembly 3 Loose the radio assembly plate by untightening M8 four bolds 4 Remove the radio assembly top plate by sliding towards upper bracket assembly ...

Страница 250: ...sure that the radio plate notch opening and RF port of radio in same direction It is also important to make sure you attach the radio assembly plate in the proper orientation as shown in figure 2 Insert M6 bolts through plate into radio enclosure 3 Fix the plate by tightening four bolts with a torque setting on 2 0 5 Nm ...

Страница 251: ...s shown in the figure Ensure that the orientation of RF port of antenna and radio are in same direction 2 Line up the radio assembly to four bolts and slide towards lower bracket assembly to lock 3 Tighten the radio assembly plate using four M8 bolts to a torque setting of 2 0 5 Nm ...

Страница 252: ...r bracket assembly 2 Hand tighten the N type connectors and the torque should not exceed more than 1 Nm Mounting of PMP 450 i AP 90 0 MHz antenna to the pole The mounting procedure of PMP 450i AP 900 MHz and antenna to the pole is given below 1 Remove the upper and lower rear bracket strap from the sector antenna 2 Attach the upper and lower bracket of the antenna to the mount point by closing the...

Страница 253: ...adio on the pole secure the upper and lower bracket assemblies with a torque setting of 3 to 4 Nm as shown in Figure 1 Also ensure that inner strap of upper bracket is set to zero degree marking Figure 116 Attaching radio mounting PMP 450i AP 900 MHz antenna to the pole ...

Страница 254: ...rench These must be tightened evenly on the pole to avoid jumping stripping threads Sector antenna alignment The 900 MHz sector antenna horizontal and vertical alignment procedure is shown in 900 MHz sector antenna alignment The antenna can be aligned from 5 to 10 degree by adjusting the inner strap of the upper bracket assembly ...

Страница 255: ...lt PMP 450 Series SM 90 0 MHz Attaching the SM 90 0 MHz directional antenna to the pole 1 Unbox the directional Yagi antenna Figure 118 PMP 450i SM 900 MHz external directional antenna 2 Attach the directional antenna to the pole and insert the two U clamps into the mounting bracket of the antenna Figure 119 Attach the antenna to the pole ...

Страница 256: ...imately 6 to 7 Nm or less to avoid deforming the pole Figure 120 Fixing the nuts Radio mounting to the antenna 1 Align the radio to E bracket and slide towards right to lock on the antenna as shown in below figure Figure 121 Fixing the radio to the antenna ...

Страница 257: ...to horizontal polarization interfaces of the antenna with RF cable Figure 122 Connecting RF cable to the radio Directional Yagi antenna alignment The directional Yagi antenna horizontal and vertical alignment procedure is shown below The Yagi antenna can be aligned for 15 to 15 degree ...

Страница 258: ...Chapter 5 Installation 258 Figure 123 Yagi antenna alignment horizontally Figure 124 Yagi antenna alignment upward tilt ...

Страница 259: ...m Series 5 GHz AP To mount and connect an integrated ODU proceed as follows 1 Inventory the parts to ensure that you have them all before you begin The full set of parts is shown in PMP 450m Series 5 GHz AP unbox view Note The additional nuts provided for top and bottom brackets are used to hold the long bolts in position during installation PMP 450m Series 5 GHz AP unbox view 2 Attach the bottom ...

Страница 260: ... two M8 nuts by applying 5 Nm torque 4 Fix the front and rear strap assembly to the upper bracket using two bolts Do not tighten the nuts now Note The PMP 450m antenna operates with 2 degrees of electrical down tilt 5 Fix the front and rear strap assembly to the bottom bracket using two bolts Do not tighten the nuts now ...

Страница 261: ...nnect an integrated ODU proceed as follows 1 Inventory the parts to ensure that you have them all before you begin The full set of parts is shown in PMP 450m Series 5 GHz AP unbox view Note The additional nuts provided for top and bottom brackets are used to hold the long bolts in position during installation PMP 450m Series 3 GHz AP unbox view 2 Attach the bottom bracket to the ODU using 2 hex bo...

Страница 262: ... tilt 5 Fix the front and rear strap assembly to the bottom bracket using two bolts Do not tighten the nuts now 6 See PMP 450m Series AP for the grounding procedure See PMP 450m Series AP for the mounting procedure PMP PTP 450 i Series AP SM BH To mount and connect an integrated ODU proceed as follows 1 Fix the mounting plate to the back of the ODU using the four M6 bolts and spring and plain wash...

Страница 263: ...shers 5 If the ODU is mounted outdoors weatherproof the N type connectors when antenna alignment is complete using PVC tape and self amalgamating rubber tape Figure 127 Attaching the bracket body Connecting Cat5e Ethernet cable Connect ing an RJ45 and gland t o a unit Perform this task to connect the Ethernet cable to an AP To connect the Ethernet cable with a gland to an AP unit proceed as follow...

Страница 264: ...o the unit body Note Do not fit the back shell prior to securing the gland body 4 Once the gland is fully hand screwed into the unit tighten it one full rotation only with a 1 1 8 inch spanner wrench 5 When the gland body has been fitted tighten the gland back shell Caution Do not over tighten the gland back shell as the internal seal and structure or RJ45 port may be damaged Figure 128 Ethernet c...

Страница 265: ...tic watertight bushing from the compression fins being careful not to damage the bushing 3 Unscrew the gland body from the AP making sure that the Ethernet cable is not rotating while disengaging the gland body from the AP housing 4 Use a small screwdriver to depress the RJ45 locking clip 5 Unplug the RJ45 cable 6 Remove the gland from the cable if necessary Installing ODU Inst alling a 450 Plat f...

Страница 266: ... the AP in the proper direction and downward tilt 5 Attach the cables to the AP See Powering the AP SM BH for test configuration 6 Waterproof the cables See section Attaching and weatherproofing an N type connector Inst alling a 450 Plat form Family SM Installing a 450 Platform Family SM consists of two procedures l Physically installing the SM on a residence or other location and performing a coa...

Страница 267: ...aptop fails to access the interface of the SM follow the procedure Radio recovery mode 17 Log in as admin on the ODU Configure a password for the admin account and log off 18 Log back into the SM as admin or root using the password that you configured 19 For coarse alignment of the SM use the Alignment Tool located at Tools Alignment Tool Optionally connect a headset to the AUX SYNC port on the SM...

Страница 268: ...uring this interval self tests and other diagnostics are being performed 6 Access Configuration General page of the BHM for Synchronization configuration 7 If a CMM4 is connected set the Sync Input parameter to the AutoSync or Autosync Free Run selection Inst alling a 450 Plat form Family BHS To install a PTP 450 platform Series BHS perform the following steps Procedure 8 Installing a BHS 1 Choose...

Страница 269: ...PTP 450i Series ODU into the ODU port of the PSU Other devices may be damaged due to the non standard techniques employed to inject DC power into the Ethernet connection between the PSU and the ODU Do not plug any device other than a Cambium 450 Platform PSU into the PSU port of the ODU Plugging any other device into the PSU port of the ODU may damage the ODU and device Follow this procedure to in...

Страница 270: ... a 14 port EtherWAN switch and is also available without a switch The CMM4 originally shipped with a 9 port EtherWAN switch l Surge suppression on the controller board for the incoming 30V DC and 56V DC power lines and GPS coax cable l Auto negotiation on the Ethernet ports Ports will auto negotiate to match inputs that are either 100Base T or 10Base T and either full duplex or half duplex when th...

Страница 271: ...to connect the screen of the main drop cable to the metal of the supporting structure using the cable grounding kit Cambium part number 01010419001 To identify suitable grounding points refer to Hazardous locations 1 Remove 60 mm 2 5 inches of the drop cable outer sheath 2 Cut 38mm 1 5 inches of rubber tape self amalgamating and fit to the ground cable lug Wrap the tape completely around the lug a...

Страница 272: ...e ties with pliers Cut the surplus from the cable ties 5 Cut a 38mm 1 5 inches section of self amalgamating tape and wrap it completely around the joint between the drop and ground cables 6 Use the remainder of the self amalgamating tape to wrap the complete assembly Press the tape edges together so that there are no gaps ...

Страница 273: ... to top The edges of each layer should be 25mm 1 inch above A and 25 mm 1 inch below B the previous layer 9 Prepare the metal grounding point of the supporting structure to provide a good electrical contact with the grounding cable clamp Remove paint grease or dirt if present Apply anti oxidant compound liberally between the two metals 10 Clamp the bottom lug of the grounding cable to the supporti...

Страница 274: ...seal the RF connections before installing the unit at the deployment site Note N type connectors should be tightened using a torque wrench set to 15 lb in or 1 7 Nm If a torque wrench is not available N type connectors may be finger tightened Use this procedure to weatherproof the N type connectors fitted to the connectorized ODU and external antenna if recommended by the antenna manufacturer 1 En...

Страница 275: ...it so that it will wrap completely around the connector and cable 6 Press the tape edges together so that there are no gaps The tape should extend 25 mm 1 inch beyond the PVC tape 7 Wrap a layer of 50 mm 2 inch PVC tape from bottom to top starting from 25 mm 1 inch below the edge of the self amalgamating tape overlapping at half width ...

Страница 276: ...lternate directions l Second layer top to bottom l Third layer bottom to top l Fourth layer top to bottom l Fifth layer bottom to top The bottom edge of each layer should be 25 mm 1 inch below the previous layer 9 Check the completed weatherproof connection Note A video of this procedure can be found at https www youtube com watch v a twPfCVq4A ...

Страница 277: ...iance The EMC specification type approvals that have been granted for 450 Platform Family are listed under EMC emissions compliance Table 125 EMC emissions compliance Region Specification USA FCC Part 15 Class B Canada RSS Gen International EN 301 489 1 V2 1 1 EN 301 489 17 V3 1 1 EN 301 489 4 V3 1 1 Human exposure to radio frequency energy Relevant standards USA and EC applicable when working wit...

Страница 278: ...aintain the minimum separation distances from all persons The applicable FCC power density exposure limit for RF energy in the 3 4 9 5 4 and 5 8 GHz frequency bands is 10 W m2 and in 900 MHz frequency band is 6 W m 2 For more information see Human exposure to radio frequency energy on page Human exposure to radio frequency energy on the previous page The applicable ISEDC power density exposure lim...

Страница 279: ...wing tables l P burst maximum average transmit power during transmit burst Watt l P maximum average transmit power of the radio Watt l G total transmit gain as a factor converted from dB l S power density Watt m2 l d minimum safe separation distance from point source meters Table 126 FCC minimum safe distances PMP 450m 3 GHz and 5 GHz 5 1 GHz 5 2 GHz 5 4 GHz and 5 8 GHz Band GHz Antenna PG W S W m...

Страница 280: ... MicroPoP APs 4 9 GHz 5 1 GHz 5 2 GHz 5 4 GHz and 5 8 GHz Band GHz Antenna P W G dBi S W m2 d m 4 9 Omni 0 501 9 10 0 0 18 Sector 0 501 13 10 0 0 28 5 1 Omni 0 501 9 10 0 0 18 Sector 0 199 13 10 0 0 18 5 2 Omni 0 125 9 10 0 0 09 Sector 0 050 13 10 0 0 09 5 4 Omni 0 125 9 10 0 0 09 Sector 0 050 13 10 0 0 09 5 8 Omni 0 501 9 10 0 0 18 Sector 0 199 13 10 0 0 18 Table 129 FCC minimum safe distances PM...

Страница 281: ...enna connectorized 0 316 40 0 16 dBi 10 0 0 32 Panel integrated 0 251 79 0 19 dBi 10 0 0 40 4 9 GHz Omni directional 0 2138 0 2512 20 0 13 dBi 10 0 0 17 90 sector antenna 0 2138 0 2512 50 0 17 dBi 10 0 0 26 2ft directional flat plate 0 2138 0 2512 631 0 28 dBi 10 0 0 93 4ft directional parabolic 0 851 0 1000 2344 0 34 9 dBi 10 0 1 14 6ft directional parabolic 0 1413 0 1659 5248 0 37 2 dBi 10 0 2 1...

Страница 282: ...dBi 10 0 0 08 5 8 GHz Omni directional 0 24 0 28 20 0 13 dBi 10 0 0 18 90 sector 0 10 0 12 50 0 17 dBi 10 0 0 18 2ft directional flat plate 0 54 0 63 708 0 28 5 dBi 10 0 1 57 4ft directional parabolic 0 54 0 63 3388 0 35 3 dBi 10 0 3 43 6ft directional parabolic 0 54 0 63 6457 0 38 1 dBi 10 0 4 74 Table 131 FCC minimum safe distances PMP PTP 450 900 MHz 2 4 GHz 3 65 GHz and 5 GHz Band Antenna P bu...

Страница 283: ... dBi 10 0 0 19 Integrated Dish 450d 0 158 316 25 dBi 10 0 0 63 Table 132 ISEDC minimum safe distances PMP 450m 3GHz and 5 GHz 4 9 GHz 5 4 GHz and 5 8 GHz Band GHz Antenna PG W S W m2 d m 3 45 90 sector 851 6 85 3 14 3 65 90 sector 33 84 7 12 0 61 4 9 90 sector 174 8 75 1 16 5 4 90 sector 0 85 9 39 0 08 5 8 90 sector 3 38 9 83 0 17 Table 133 ISED minimum safe distances PMP 450 MicroPoP APs 4 9 GHz ...

Страница 284: ... 13 0 15 6 29 5 4 Integrated 0 501 8 9 39 0 15 6 29 5 8 Integrated 0 501 8 9 69 0 15 6 29 Table 135 ISEDC minimum safe distances PMP PTP 450b 3 65 GHz 4 9 GHz 5 1 GHz 5 2 GHz 5 4 GHz and 5 8 GHz Band GHz Antenna P W G dBi S W m2 d m S 20 cm W m2 3 5 Dish 0 794 20 6 99 0 88 158 0 3 65 GHz Lower Canada Dish 0 199 20 7 13 0 44 39 7 3 65 GHz Upper Canada Dish 0 199 20 7 13 0 44 39 7 4 9 Dish 0 501 24 ...

Страница 285: ...d 0 316 50 0 17 dBi 6 99 0 39 90 sector antenna connectorized 0 316 40 0 16 dBi 6 99 0 35 Panel integrated 0 316 79 0 19 dBi 6 99 0 49 3 65 GHz Lower Canada 90 sector antenna integrated 0 316 50 0 17 dBi 7 13 0 42 90 sector antenna connectorized 0 316 40 0 16 dBi 7 13 0 37 Panel integrated 0 251 79 0 19 dBi 7 13 0 47 3 65 GHz Upper Canada 90 sector antenna integrated 0 316 50 0 17 dBi 7 13 0 42 90...

Страница 286: ...bolic 0 001 0 001 707 9 28 5 dBi 9 39 0 06 5 8 GHz Omni directional 0 24 0 28 20 0 13 dBi 9 69 0 20 90 sector 0 10 0 12 50 1 17 dBi 9 69 0 20 2ft directional flat plate 0 54 0 63 707 9 28 5 dBi 9 69 1 67 4ft directional parabolic 0 54 0 63 3388 4 35 3 dBi 9 69 4 82 Table 137 ISEDC minimum safe distance PMP PTP 450 900 MHz 2 4 GHz 3 5 3 65 GHz and 5 GHz Band Antenna P burst W G dBi S W m2 d m 900 M...

Страница 287: ...9 0 10 Reflector 0 158 316 25 dBi 9 69 0 064 CLIP 0 158 50 17 dBi 9 69 0 25 LENS 0 158 28 14 5 dBi 9 69 0 19 Integrated Dish 450d 0 158 316 25 dBi 9 69 0 64 1 P maximum average transmit power capability of the radio including cable loss Watt Note Gain of antenna in dBi 10 log G The regulations require that the power used for the calculations is the maximum power in the transmit burst subject to al...

Страница 288: ...istance proportionnellement au gain de l antenne Capacité de puissance d émission moyenne maximale de la radio comprenant la perte dans les câble de connexion W 2 G total transmit gain as a factor converted from dB Gain total d émission converti à partir de la valeur en dB 3 S power density W m2 Densité de puissance W m2 4 d minimum distance from point source meters Distance minimale de source pon...

Страница 289: ...2012 The approval is given by certificate number EMT126ATEX0003X issued by Element Materials Technology with the specific level of coverage shown below l II 3 G Ex ic IIC T4 l II Equipment group surface applications l 3 Equipment category infrequent exposure l G Atmosphere Gas l ic Protection concept intrinsic safety l IIC Gas group up to and including Hydrogen and Acetylene l T4 Temperature class...

Страница 290: ...onales nécessaires pour faire fonctionner ce produit Celles ci doivent être obtenus avant d utiliser le produit dans un pays particulier Contactez les administrations nationales concernées pour les détails des conditions d utilisation des bandes en question et toutes les exceptions qui pourraient s appliquer Attention Les changements ou modifications non expressément approuvés par les réseaux de C...

Страница 291: ...CO Use of 4940 to 4990 MHz band 5 4 GHz Acuerdo del 27 de noviembre de 2012 5 8 GHz NOM 121 SCT1 2009 USA 900 MHz FCC Part 15 247 FCC Part 15 Class B 2 4 GHz FCC Part 15 247 FCC Part 15 Class B 3 6 GHz FCC Part 96 FCC Part 15 Class B 4 9 GHz FCC 47 CFR Part 90 FCC Part 15 Class B 5 1 GHz FCC 47 CFR Part 15 E FCC Part 15 Class B 5 2 GHz FCC 47 CFR Part 15 E FCC Part 15 Class B 5 4 GHz FCC 47 CFR Pa...

Страница 292: ...uipment operating in the 5 1 GHz and 5 4 GHz bands is compliant with CEPT Resolution 229 REV WRC 12 Operating the 450 Platform Family in the bands 5150 to 5350 MHz and 5470 to 5725 MHz is granted providing it is not causing interference to the existing primary services allocated to those bands For compliant operation in the 5250 to 5350 MHz band the transmit power from the integrated antenna or a ...