Chapter 1: About This User Guide
14
l
All grounding cables must be a minimum size of 10 mm2 csa (8AWG), preferably 16 mm2 csa
(6AWG), or 25 mm2 csa (4AWG).
Grounding guidelines
Implement the following requirements, when routing, fastening and connecting grounding cables:
l
Ensure the grounding conductors run as short, straight, and smoothly as possible, with the minimum
bends and curves.
l
Do not install the grounding cables with drip loops.
l
All bends must have a minimum radius of 203 mm and a minimum angle of 90° as shown in below
figure. A diagonal run is preferable to a bend, even though it does not follow the contour or run
parallel to the supporting structure.
l
Route all bends, curves and connections towards the grounding electrode system, ground rod, or
ground bar.
l
Securely fasten the grounding conductors.
l
Use the braided grounding conductors.
l
Use the approved bonding techniques for the connection of dissimilar metals.
Figure 1 :
Grounding cable minimum bend radius and angle
Pole or tower mount guidelines
If you need to install AP to a metal tower or pole, then in addition to the general protection requirements,
follow the below requirements:
l
Ensure that the position of the equipment is lower than the top of the tower or its lightning air
terminal.
l
Ensure that the metal tower or pole is correctly grounded.
l
Install a grounding kit at the first point of contact (top), between the drop cable and the tower.
l
Install a grounding kit at the bottom of the tower, near the vertical to horizontal transition point.