Connecting 60 GHz cnWave™ Products
27
Connecting 60 GHz cnWave™ Products
Installing PSU and powering the ODU
Install one of the following types of PSU:
l
60W DC power injector
l
AC/DC power supply
l
V1000 power injector
Warning
Always use an appropriately rated and approved AC supply cord-set in accordance with the
regulations of the country of use.
Attention
Utilisez toujours un cordon d'alimentation secteur approprié et approuvé conformément aux
réglementations du pays d'utilisation.
Attention
As the PSU is not waterproof, locate it away from sources of moisture, either in the
equipment building or in a ventilated moisture-proof enclosure. Do not locate the PSU in a
position where it may exceed its temperature rating.
Attention
Le bloc d'alimentation n'étant pas étanche, placez-le à l'écart des sources d'humidité, que ce
soit dans le bâtiment de l'équipement ou dans une enceinte ventilée étanche à l'humidité. Ne
placez pas le bloc d'alimentation dans une position où il pourrait dépasser sa température
nominale.
Attention
l
Do not plug any device other than a 60 GHz cnWave™ ODU into the ODU port of the
PSU. Other devices may get damage due to the non-standard techniques employed to
inject DC power into the Ethernet connection between the PSU and the ODU.
l
Do not plug any device other than a Cambium 60 GHz cnWave™ PSU into the PSU
port of the ODU. Plugging any other device into the PSU port of the ODU may damage
the ODU and device.