2.4.1 Technical information reserved to the qualified installer
The following informations are aimed, only, at qualified technical
staff.
The specialist installer near the point of installation of the oven, must:
Place a length of power cable near the unit so as to permit the installed power cable to reach
the power socket (do not use extension cables to make this connection);
Install a suitable interlocked socket of industrial type;
Install a disconnection switch;
Install a thermal disconnector and differential switch whose sensitivity is suitable to
the current leakage from the heating elements
.
Once operating checks and inspections are finished, the installer will have to issue
the Declaration of Conformity in compliance with the provisions of Act 46/90