ZXIMCU PT01 P200 Portable Emergency Command System Operation Manual
Page 4
© 2021 Copyright Caltta Technologies Co.,Ltd.
All rights reserved
2.2
ZXIMCU PT01 P200 Connection Operation
Step 1: Take out the device as shown below
Figure 2- 4 ZXIMCU P200 device
Step 2: Connect the A connector of the power line to RRU, connect B connector to
MPU, and tighten them up
Figure 2- 5 Connection between MPU and RRU with the the power line
Step 3: Connect feeder and antenna: Connect one end of the antenna feeders (2
pieces) to the RF interface of RRU, connect the other end to the RF antenna. Make
sure to tighten them up when connecting, otherwise it may cause the weak signal
and lead to failure of registration when the terminal is slightly far away from the
system.
Figure 2- 6 Connection of the feeder and antenna