                                                             SECTION 4: SELECT FROM LIST

 

 
 

making

         since 1986

 

water work

                                          

 

 
 

5. 
 
         
 
 
          
 

6.  

          Press the 

RESUME/ON

 key 

                             to turn on a selected station  
                             to compare the expected flow  
                             rate to the actual flow rate of  
                             a station. 
 

Note:

 When a station is activated to check the 

Expected Flow, all other stations on this controller 
and the controller chain, if applicable, will be turned 

OFF

. Only the selected station will stay 

ON

 for up to 

6.0 minutes. If any other key is pressed on the 
handheld all controllers will resume there prior 
activities. 

 

Note:

 Once all individual station data has been 

updated you will be required to send the changes to 
the controller. 

 

6.    

        Press the 

BACK/MENU

 key 

                             to access the 

SEND YOUR  

                             CHANGES 

screen. 

 

The SEND YOUR CHANGES screen is displayed 
(Figure 4.2.3.2).   

 

 
 

Send   Your   Changes?

YES

 

 

 

Figure 4.2.3.2 

 

Note:

 If 

YES

 was selected all changes will be sent to 

the controller at this time. If 

NO

 was selected all 

entries made on the remote will be set back to what 
they were before this session. 
 

Note:

 The Radio Remote will loop to the 

SEND 

YOUR CHANGES

 screen if any other key is pressed 

until a choice is made. 
 
 

4B.3  Turn Station Valve(s) ON / OFF: 

 

This section of the handheld unit allows the user to 
turn individual station valve(s) ON and OFF. 

 

From the SELECT A STATION screen (Figure 
4.0.3). 

 

 

1.  
 
         
 
 
          
 

2. 

         Press the 

ON/RESUME

 key once 

                             the station number desired has  
                             been chosen. 
 
This will turn the station select ON and display the 
CONTROLLER STATUS screen (Figure 4.3.1). 
 
 

ALABASTER COVE

(valves on)                 (time)

     1:                          14.6 min

12  GPM               0.46   AMPS

 

 

 

Figure 4.3.1 

3. 

        Press the 

OFF/PAUSE

 key two 

                            times (2x) to turn the selected 
                            station valve OFF. 

 

Note:

 Pressing the 

OFF/PAUSE

 key just one time 

(1x) will pause the selected station. It will still appear 
in the list and is available to be resumed. 

 

Note:

 Give the system some time to process your 

key inputs communications may take time. 

 

Press the 

PLUS/AUTO

 or 

MINUS/AUTO

 keys to scroll 

through the menu choices. 

Press the 

PLUS/AUTO

 or 

MINUS/AUTO

 keys to adjust 

the selected entry. 

 

Содержание RRe-TRAN

Страница 1: ...RRe TRAN USERS GUIDE making since 1986 water work RRe TRAN USERS GUIDE For use with firmware version 1 5a and above CHANGE 3 INCORPORATED 1 May 2008...

Страница 2: ...FLOW RATES 4B 3 TURN STATION VALVE S ON OFF 4B 4 PAUSE RESUME STATION VALVE S 4B 5 USE AUTO UP AND AUTO DOWN FUNCTION WHEN IRRIGATING ONE STATION VALVE SECTION 5 CHANGE LIST 5A ADD VIA CONTROLLER 5B...

Страница 3: ...uence Also used to increase a selected editable value 11 SELECT EDIT This button is used to make the choice of a highlighted item or to select an item for editing 8 LEFT ARROW This button is used to n...

Страница 4: ...Travel Select From List Change List Setup Battery Status There are No CONTROLLERS in the list Select a Region Delete Controllers Add via Controller PC Communications Select a Site Controller Status M...

Страница 5: ...he battery level reading is weak Note You should charge the Handheld Radio Remote unit after each use or when battery status reads weak The CHARGING STATUS screen is displayed Figure 2 0 1 CHARGING ST...

Страница 6: ...er operator by use of the RRe Interface software Example in figure 3 0 1 the hand held has been renamed to ALABASTER COVE from the default MAIN setting X in List This is the number of controllers curr...

Страница 7: ...ontroller This screen allows the user to access a controller that has been added to the handheld unit controller list The Handheld unit can store up to 270 individual controllers Figure 4 0 2 S N 2727...

Страница 8: ...CONTROLLER STATUS screen is displayed Figure 4 1 1 14 EXPECTED 14 GPM 0 46 AMPS ALABASTER COVE valves on time 4 14 9 min Figure 4 1 1 Note Figure 4 1 1 shows All Stations OFF This screen appears when...

Страница 9: ...Press the SELECT EDIT key once an access code has been entered Once access has been established the SELECT WHAT TO CHANGE screen will be displayed figure 4 2 1 2 1 2 3 SELECT WHAT TO CHANGE Station Ru...

Страница 10: ...they were before this session Note The Radio Remote will loop to the SEND YOUR CHANGES screen if any other key is pressed until a choice is made 4B 2 3 Expected Flow Rates From the SELECT WHAT TO CHAN...

Страница 11: ...ed all entries made on the remote will be set back to what they were before this session Note The Radio Remote will loop to the SEND YOUR CHANGES screen if any other key is pressed until a choice is m...

Страница 12: ...t and is available to be resumed Note Repeat steps 5 and 6 until all desired station valves have been turned OFF Note Station run times are fixed at 15 0 minutes and cannot be altered Note The maximum...

Страница 13: ...ntil all desired stations have been re activated 4B 5 Use UP AUTO and DOWN AUTO Function When Irrigating One Station Valve This section of the handheld unit allows the user to turn off the valve curre...

Страница 14: ...AMPS ALABASTER COVE valves on time 4 14 9 min Figure 4 5 3 Example In Figure 4 5 1 Station 5 is irrigating 10 3 minutes of a 15 0 minute cycle Once the MINUS AUTO key is pressed Station 5 will turn OF...

Страница 15: ...l Selection Mode SET BY USER With Handheld on the ADD A CONTROLLER screen push this button ADD CONTROLLER TO HANDHELD User Setting is CH 2 RRE CHANNEL SELECTION Figure 5 0 4 Set By User This setting i...

Страница 16: ...tion allows the user to obtain a controllers information from a desktop computer using the IR Interface Software program or by use of Command Center Software and an RRe IR Interface unit The RRe Inter...

Страница 17: ...lete the controller Note The Handheld Radio Remote will beep once for each controller as it is being deleted SECTION 6 SETUP From the MAIN MENU screen Figure 5 0 1 1 2 Press the SELECT EDIT key once T...

Страница 18: ...een title of most screens until charging takes place 6B Range Test This screen allows the user to monitor communication signal strength between the selected controller and the handheld unit From the S...

Страница 19: ...instructions 8 You as the qualified end user of the radio device must control the exposure conditions of bystanders to ensure the minimum separation distance above is maintained between the antenna a...

Страница 20: ...ate of original purchase by the owner California Sensor Corporation liability is limited solely to the replacement or repair of defective parts There are no other express warranties This warranty does...

Отзывы: