background image

7

Left=  0% :

This is the amount of water in the ET gage (measured as a percentage). Whenever the gage is refilled, this
should be reset. Press the 

%

 key, then the 

UP ARROW

 key to reset the value (the maximum setting is 99%).

Press the 

ENTER

 key after the value has been reset.

PROG :

Indicates the program that the current station is assigned to. A station can be assigned to only one program.
Press the 

CHANGE

 key until the program is highlighted. Press the 

UP ARROW

 key to select the desired program.

Estimated Mins : The Estimated Minutes is the amount of irrigation time calculated by the controller, it is the maximum amount of

irrigation that will be applied in the current 24 hour period. This setting cannot be changed directly by the user.
The time is calculated by the program based on the precipitation rate for the current station, the amount of ET in
the ET table, crop coefficients (if used), and the % of ET (described below). If any of these values are changed the
Estimated Minutes will change.

Mins Per Cycle : The Minutes Per Cycle is the maximum amount of irrigation time applied in a cycle. This setting should be the

most water you would want the current station to apply at any one time, that is before water starts to “run-off”. If
the setting is less than the Estimated Minutes (described above) there will be multiple cycle starts, until the total
time applied equals the Estimated Minutes. If the setting is more than the Estimated Minutes the run-time will be
equal to the Estimated Minutes (total run-time will never exceed the Estimated Minutes). Press the 

CHANGE 

key

until the setting is highlighted, Press the 

UP ARROW

 or 

DOWN ARROW

 key to adjust the setting.

Soak-in Time :

The Soak-in Time is the amount of time between multiple cycle starts (if there are multiple cycle starts). If there are
no multiple cycle starts, this setting will be ignored by the program. Press the 

CHANGE 

key until the setting is

highlighted, Press the 

UP ARROW

 or 

DOWN ARROW

 key to adjust the setting.

Last Min :

This is the average applied time for the last five irrigation cycles. It is for your information only.

% of ET :

This is the individual station adjustment to daily-ET. This adjustment is used to fine-tune each stations run-time. It
is one of the factors used in calculating the Estimated Minutes (described above). Press the 

CHANGE

 key to

highlight the % of ET, Press the 

UP ARROW

 or 

DOWN ARROW

 key to adjust the setting. As you make adjustments

to this setting, you will see the Estimated Minutes change. Try to make small adjustments, 5% to 10% at a time,
and allow a few days to pass before re-adjusting if necessary. Daily-ET only replaces the moisture that has
evaporated since the last irrigation cycle, if for example you have a problem with a valve, and an area becomes
stressed from lack of water, use the manual water feature to add water until the area is back to normal conditions.

The % of ET setting is used to adjust for factors such as different types of plant material (e.g. turf would generally
have a higher adjustment factor that shrubs), soil conditions (e.g. sandy soils might have a higher adjustment
factor than clay type soils because they don’t hold moisture as long), terrain (e.g. the system at the top of a slope
might have a higher adjustment factor that the system at the toe of a slope). If this adjustment ends up a large
number from 100% (in either direction), you should re-evaluate your precipitation rate numbers for that station,
which were entered in the Set-Up program (described earlier in this guide).

9. 12-Month Schedule

If 12-Month Schedule was enabled (while in the Set-Up program described earlier in this guide), it must be programmed after
leaving set-up. When using the 12-Month Schedule, you will be able to pre-program for each month of the year, every stations
Minutes Per Cycle and Soak-in Time settings, and each programs Start Time and Water Days. To program 12-Month Schedule
starting from the main display, Press the 

REVIEW

 key, the display will appear as shown below.

STN   01

(January)

PROG   A

Mins  Per  Cycle :

4

Soak-in  Time :

5

The month being programmed is shown at the top of the display. Press the 

CHANGE

 key (a message will appear saying you are

about to make changes to the Master Schedule (12-month schedule). Press the 

CHANGE

 key once more to highlight the “Mins

Per Cycle”. Press the 

UP ARROW

 or 

DOWN ARROW

 key to change the setting. Press the 

CHANGE

 key to move the highlight to

“Soak-in Time”, Press the 

UP ARROW

 or 

DOWN ARROW

 key to change the setting. Press the 

STATION UP

 or 

STATION DOWN

key to change to another station, make desired changes as described above. After all station settings have been programmed,
Press the 

ENTER

 key to save changes. Then press the 

SCHEDULE

 key, the Schedule screen will appear as shown below.

PROG  A

START  TIME  is    OFF

week  1

S U

MO

TU

WE

T H

FR

SA

- -

--

- -

- -

- -

- -

- -

The current program will be shown in the upper left corner, the lines beneath each day represent an off water day. Press the

CHANGE

 key, the current day will be highlighted. Press the 

UP ARROW

 key to turn the day on, Press the 

DOWN ARROW

 key to

Содержание ET1

Страница 1: ...ogal Suite P Carlsbad CA 92011 760 438 0525 Fax 760 438 2619 www calsense com Real Time ET Based Water Management A Guide to Programming the ET1 Irrigation Controller for use in Daily ET Mode Stock No...

Страница 2: ...es whenever scheduled irrigation is set to occur Since ET is determined by weather conditions irrigation run times change daily based on current weather conditions This helps conserve water and create...

Страница 3: ...w it got into the ET table h historical g ET Gage and e edited The upper left hand value is today s ET it will remain a historical number until 8 00 PM each night at which time the controller will pla...

Страница 4: ...of ET In this situation each Monday would have station run times much longer than any other day of the week which could cause over watering problems With ET averaging ON the extended run times on Mon...

Страница 5: ...o rain bucket installed and you are not sharing rain data using the Calsense Command Center program these settings will have no effect on daily ET Daily ET cont d RAIN BUCKET Stop Irrigation after inc...

Страница 6: ...ce data to drive the program In either case you would want to use the historical ET for the area you are located in The ET1 controller stores historical ET information for 21 counties in California an...

Страница 7: ...ts to this setting you will see the Estimated Minutes change Try to make small adjustments 5 to 10 at a time and allow a few days to pass before re adjusting if necessary Daily ET only replaces the mo...

Страница 8: ...e 4 View the amount of each station s hold over time with the option of clearing a station s hold over time Negative hold over time hold over time generated by a rain bucket will be shown as a negativ...

Страница 9: ...out of the system Then simultaneously make note of the meter reading and start timing using a stopwatch After 3 minutes has elapsed make note of the meter reading again Subtract the starting meter rea...

Отзывы: