The usable rain in the rain table can be thought of as negative ET, (or negative hold-over). When scheduled irrigation is set to occur,
the controller will subtract the negative hold-over in the rain table from the ET in the ET table, and calculate a run-time with the
reduced ET value. If the negative hold-over is greater than ET, no irrigation will occur, this will continue until all of the negative hold-
over is subtracted from ET, then irrigation will begin again. The amount of time that irrigation is reduced or halted is determined by
the rate and amount of rainfall. Usable rain is determined by the settings programmed at the Rain Bucket Setup screen 

(See

Section 7 for more information about Rain Bucket settings)

.

To view the ET table and the rain table (this can only be done if the ET1 controller is in daily-ET mode), press the 

STATUS

 key, the

ET table will appear. Press the 

REVIEW

 key to toggle between each table 

(See Section 10 for more information about the Status

screen).

7. Setting Up The ET1 Controller For Use In Daily-ET Mode

When programming the ET1 Controller, there are four keys which are used repeatedly, the 

CHANGE

 key, 

UP ARROW

 key, 

DOWN

ARROW

 key and the 

ENTER

 key. They are used in the following manner:

Press the 

CHANGE

 key to highlight an item to be changed.  It is also used to move the highlighted cursor around the display to

other items (if necessary). Press the 

UP ARROW

 or 

DOWN ARROW

 Keys to make a change to the highlighted item. Press 

ENTER

after making changes to proceed to the next screen.

Start by accessing the ET1 Set-Up Program. To access Set-Up, a four key code must be entered as follows. Press the 

IRRIGATE

ON/OFF

 key (this will not be necessary if the controller is already off). Press 

STATION UP

, Press 

STATION DOWN

 then Press the

UP ARROW

 key. The following pages describe each screen, and the settings necessary to set-up the ET1 controller in daily-ET

mode.

The ET table stores the last 28 days of ET values. In the example shown on the previous page, the ET table has a combination of
historical ET,  actual real-time ET and user edited ET. The letter next to each value indicates how it got into the ET table, h=historical,
g=ET Gage and e=edited.

The upper left hand value is today’s ET, it will remain a historical number until 8:00 PM each night, at which time the controller will
place the total real-time ET from the ET Gage into that position (if an ET Gage is not attached and you are not sharing ET, the value
will remain historical). The total real-time ET value is the amount of ET that has occurred since 8:00 PM the previous night. Scheduled
irrigation occurring after 8:00 PM will use that value to calculate station run-times. At midnight all numbers will shift one place to the
right, a historical number will be placed in today’s position (upper left) and the number from 28 days ago (lower right) will be deleted.

If at the time scheduled irrigation is set to occur, there was no scheduled irrigation the previous night, the controller will combine the
ET values for the last 2 days and calculate station run-times using the total of the two values (if it had been 3 days since the last
scheduled irrigation it would combine the last 3 days of ET values and so on, for up to 28 days of total ET).

6. Rain Table

The rain table is where the controller stores rainfall values (measured in inches). The values in this table can only be generated from
a rain bucket wired to the controller, or shared using the Calsense Command Center program from a rain bucket wired to a
controller. In the example below the rain table has a combination of values. The letter next to the value indicates what the value
represents:

o=original, this value is zero which means it has not been altered, it has no effect on daily-ET

m=below minimum, the below minimum value is measured rain but it is not used to offset daily-ET.

r=usable rain, this value is rain that is used to offset daily-ET.

0.00  Rain  Amounts  From  10/29/2001  Back

Mon

Sun

Sat

Fri

T h u

Wed

Tue

o .00

o. 00

m .06

o .00

r .23

r .18

o. 00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

o .00

( push  <review>  to  see  ET  table )

Daily  ET  Section :

USE  DAILY  ET  TO  CALCULATE  RUN-TIMES ?    

NO

After Entering Set-Up, Press the 

ENTER

 key repeatedly to proceed through each screen until the first DAILY ET screen appears

(shown above). To enable daily-ET, Press the 

UP ARROW

 key to change the highlighted selection from NO to YES.

Содержание ET1

Страница 1: ...ogal Suite P Carlsbad CA 92011 760 438 0525 Fax 760 438 2619 www calsense com Real Time ET Based Water Management A Guide to Programming the ET1 Irrigation Controller for use in Daily ET Mode Stock No...

Страница 2: ...es whenever scheduled irrigation is set to occur Since ET is determined by weather conditions irrigation run times change daily based on current weather conditions This helps conserve water and create...

Страница 3: ...w it got into the ET table h historical g ET Gage and e edited The upper left hand value is today s ET it will remain a historical number until 8 00 PM each night at which time the controller will pla...

Страница 4: ...of ET In this situation each Monday would have station run times much longer than any other day of the week which could cause over watering problems With ET averaging ON the extended run times on Mon...

Страница 5: ...o rain bucket installed and you are not sharing rain data using the Calsense Command Center program these settings will have no effect on daily ET Daily ET cont d RAIN BUCKET Stop Irrigation after inc...

Страница 6: ...ce data to drive the program In either case you would want to use the historical ET for the area you are located in The ET1 controller stores historical ET information for 21 counties in California an...

Страница 7: ...ts to this setting you will see the Estimated Minutes change Try to make small adjustments 5 to 10 at a time and allow a few days to pass before re adjusting if necessary Daily ET only replaces the mo...

Страница 8: ...e 4 View the amount of each station s hold over time with the option of clearing a station s hold over time Negative hold over time hold over time generated by a rain bucket will be shown as a negativ...

Страница 9: ...out of the system Then simultaneously make note of the meter reading and start timing using a stopwatch After 3 minutes has elapsed make note of the meter reading again Subtract the starting meter rea...

Отзывы: