Follow the routine maintenance schedules
and the promptly replace damaged parts,
this will allows the device to work in the
best conditions. Use only original spare
parts provided from Calpeda or from an
authorized distributor.
Don’t remove or change the labels placed
on the device. Do not start the device in
case of defects or damaged parts.
Maintenance operations, requiring full or
partial disassembly of the device, must
be done only after disconnection from the
supply.
All the power terminals and other terminals
must be inaccessible after installation is
completed.
4.2. Residual risks
The device, for its design and designation (in
accordance to intended use and safety standard),
has no residual risks.
4.3. Safety icons and information
Please refer to all product manuals supplied in the
pack.
4.4. Individual protection devices
During installation, starting and maintenance it is
suggested to the authorized operators to consider
the use of individual protection devices suitable for
described activities.
During ordinary and extraordinary maintenance
interventions, safety gloves are required.
Signal individual protection device
HAND PROTECTION
(gloves for protection against chemical,
thermal and mechanical risks).
5. TRANSPORT AND HANDLING
During transport do not stack heavy objects on it.
Make sure that during transport the vehicle that is
used, is big enough for the total dimension of the
package.
The vehicles used must be suited for the dimensions
and weights of the chosen device.
5.1. Handling
If the weight exceeds 25 Kg the package
must be handled by two person at the same
time.
The weight of the booster set may require the use
of specialist lifting equipment in order that it can
be handled safely. During lift or manoeuvre of the
equipment never use the set pipe-work, vessels or
fittings as a lifting point.
5.2. Site storage
It is advised that once the set has been delivered it
must be placed immediately in a dry, frost and dust
free area and secured from interference. Respect
the following storage conditions :
- Ambient temperature: from -10°C up to +70°C
- Relative humidity: from 20% to 85% without
condensing.
6. INSTALLATION
6.1. Ambient requirements and installation site
dimensions
The customer has to prepare the installation site in
order to guarantee the right installation and in order
to fulfill the device requirements (electrical supply,
etc...).
The place where the device will be installed must
fulfill the requirements in the paragraph 3.2. It's
absolutely forbidden to install the machine in an
environment with potentially explosive atmosphere.
6.2. Unpacking
i
Inspect the device in order to check any
damages which may have occurred during
transportation.
Package material, once removed, must be
discarded/recycled according to local laws of the
destination country.
6.3. Installation
The booster set should not be installed in roof
spaces as the small level of vibration associated
with rotating equipment will cause disturbance, and
considerable damage could occur in the event of
water leakage or loss during commissioning and/
or service.
The booster sets should be installed in a well-
ventilated, dry frost free position.
External installation should make use of a rodent
proof enclosure with adequate ventilation and
protected from freezing.
A space around the set of approximately 750 mm
should be provided for access and servicing.
Adequate drainage should be provided with
protection from water damage in the immediate
vicinity should a leak or spillage occur.
Adequate lighting should be provided for service,
inspection and commissioning.
6.3.1. Positioning / Foundation
The set should be installed with anti-vibration
mounting pads and anti-vibration pipe coupling
especially in noise sensitive areas. Otherwise
install the set on a level concrete plinth which will
not distort or twist the base-plate, use shims if
required. Always install in a horizontal position and
use adequate fixings. Do not install on a wooden
substructure or any potentially flexible substructure.
6.4. Pipes
Ensure the insides of pipes are clean and
unobstructed before connection.
ATTENTION: The pipes connected to the booster
set should be secured to rest clamps so that they
do not transmit stress, strain or vibrations to the
booster set.
The pipe diameters must not be smaller than the
booster set connections.
Isolation valves should be fitted before the set
suction manifold and on the discharge manifold
after the set to allow the set to be removed without
a major loss of water in the system.