background image

5

D. 

TEMPERATURE CONTROL

1. 

BUILT-IN Thermostat - Heaters with a factory installed 
thermostat are prewired and require only power 

connection. The thermostat sensing bulb must be 
assembled into its final position. See B.4.7. for final 
assembly. 

2. 

The thermostat supplied is a high quality device with a 

factory calibrated range of 50 to 104°F (10 to 40°C). Due 
to the proximity of the sensing bulb to the heater, the 
actual thermostat setting will not be the same as the 

desired room ambient temperature. This is normal with all 
unit mounted thermostats. It should be a simple matter to 

find the setpoint to provide the desired comfort level. 

3. 

REMOTE LINE VOLTAGE THERMOSTAT - A remote 
thermostat rated to operate on full voltage may be 

desired. Installation and wiring of the selected thermostat 

must comply with the manufacturer’s instructions. 
CCI Thermal Technologies Inc. can supply appropriate 
thermostats. 

E. 

MAINTENANCE

WARNING

WARNING. 

The BX convection heater is constructed to 

operate in tough industrial applications with minimum 
maintenance. However, some routine maintenance is 
recommended to extend the life of the heater and its 
components. ALWAYS DISCONNECT THE 
ELECTRICAL SOURCE BEFORE PERFORMING ANY 
MAINTENANCE.

1. 

TERMINAL ENCLOSURE - The periodic intervals, but 

not more than once a year, open the terminal enclosure 
to inspect for cleanliness and dampness. Vacuum any 

dust and wipe up any moisture. Check all electrical 
connections and tighten if necessary. 

2. 

HEATER PAINT FINISH - The BX convection heater 
is finished with a heavy duty enamel paint to provide 
maximum resistance to corrosion due to air-born 

contaminants. We recommend the cabinet to be wiped 
down periodically using a mild detergent.

Содержание BX2011S

Страница 1: ...ts ISO 9001 WARNING WARNING The BX convection heater is a heavy duty baseboard designed for use in industrial environments and is not intended for use in residential and commercial locations The heater is not thermally protected and air flow obstruction with flammable materials could create a fire hazard All openings must be clear at all times ...

Страница 2: ...lectrical power supply available DO NOT CONNECT THE BX CONVECTION HEATER TO AN ELECTRICAL SUPPLY VOLTAGE OTHER THAN THAT SHOWN ON THE PRODUCT NAMEPLATE 3 The BX convection heater is CSA approved for operation in non hazardous areas only Ensure that no hazardous conditions exist before energizing the heater TABLE OF CONTENTS A Initial Inspection 2 B Installation 3 C Electrical Connections 4 D Tempe...

Страница 3: ...ounting details 4 1 Remove the two screws located on the front panel 4 2 Remove the heater front panel 4 3 Back off the screws on the universal mounting legs enough to allow penetration of the screw heads through the keyhole openings in the back of the heater 4 4 Slide the heater assembly to the side so that the mounting screws engage the keyhole openings 4 5 Tighten the mounting screws to secure ...

Страница 4: ...ination 1 2 3 4 knockouts are provided for easy connection 4 The BX convection heater is completely prewired internally Connect the power conductors and control conductors to the terminations as illustrated on the wiring diagram enclosed 5 The schematic wiring diagrams shown below illustrate the BX convection heater with various control options Some of this equipment is optional and may not be inc...

Страница 5: ...nd wiring of the selected thermostat must comply with the manufacturer s instructions CCI Thermal Technologies Inc can supply appropriate thermostats E MAINTENANCE WARNING WARNING The BX convection heater is constructed to operate in tough industrial applications with minimum maintenance However some routine maintenance is recommended to extend the life of the heater and its components ALWAYS DISC...

Страница 6: ...refix Heater Element V Phase BX2011S 120 1 IXS11132 10 BX2021S BX2023S 208 1 3 IXS11132 13 BX2031S BX2033S 240 1 3 IXS11132 14 BX2071S 480 1 IXS11132 11 BX2073S 480 3 IXS11132 15 BX2081S 600 1 IXS11132 12 BX2083S 600 3 IXS11132 16 BX2011 120 1 IXS11132 01 BX2021 BX3021 BX2023 BX3023 208 1 3 IXS11132 02 BX2031 BX3031 BX2033 BX3033 240 IXS11132 03 BX2071 BX3071 BX2073 BX3073 480 IXS11132 07 BX2081 B...

Страница 7: ...NOTES ...

Страница 8: ...not so as to limit the generality of the foregoing includes physical chemical or mechanical abuse accident improper installation of the product improper storage and handling of the product improper application or the misalignment of parts No warranty applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation The Company neither assumes nor auth...

Отзывы: