CIRCUIT
2.5A
VENTILATEUR
4.5A
VALEURS DISJONCTEUR
COMPRESSEUR
32.8A
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS
SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON
CONDITION
WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT
MAXIMUM RATE
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH
REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM
ABOVE CONDITIONS APPLY
VOYANT
ALIMENTATION
PRINCIPALE
DISJONCTEUR
COMMANDE
MONITEUR
DE PHASES
CONTACTEUR
(COMP 2)
VENTILATEUR
COMP
2
RECHA
UFFEUR
COMPRES
SEUR
PRESSOSTAT
HP
VOYANT
REFROIDISSEMENT
SOUPAPE
D'INVERSION
DISJONCTEUR
COMP 2
DISJONCTEUR
(COMP 1)
DEMARRAGE AMORTI
DISJONCTEUR THERMIQUE
ET VOYANT DEFAUT
SI INSTALLE
BORNES D'INTER- VERROUILLA
GE
CHAUFFAGE
VOYANT
DEMARREUR OU
CONTACTEUR DE DEBIT
PRESSOSTAT BP
PROTECTION ELECTRONIQUE
COMPRESSEUR 1
VOYANT DEFAUT
VEILLE
COMMUTATEUR
VOYANT
TEMP OK
PRESSOSTAT ET VOYANT
LIMITE DE
REFROIDISSEMENT
COMMUTATEUR
DEBIT D'EAU
COMP
1
PROTECTION ELECTRONIQUE
COMPRESSEUR 2
ELECTROVANNE
(ARRET LIGNE
LIQUIDE)
VOYANT
DEBIT D'EAU
DISJONCTEUR COMP 2
AUX
RECHA
UFFEUR
COMPRES
SEUR
CONTACT 7 ET 8 FERMES EN MODE FROID
THERMOSTAT 2 CANAUX
CONTACT 6 ET 4 FERMES EN MODE CHAUD
3 N/F (VEILLE)(O)
2 N/O (MARCHE)(I)
(COM) C
(N/F) L
H (N/O)
THERMOSTAT
DEGIVRAGE
(10 SECS)
6 (N/F)
4 (N/F)
2 (N/F)
12 (N/F)
DISJONCTEUR
(VENTILATEUR)
(N/O)
A
B
RELAIS (R3)
(COM) 1
4 (N/O)
2 (N/O)
TEMPORISATION T3
22 (N/F)
A1
A2
(V)
(U)
1
2 (N/F)
(N/O)
4 (N/O)
1 (N/F
)
(COM) 7
RELAIS (R2)
16 (N/F)
TEMPORISATION T1
(12 HEURES)
A
B
RELAIS (R1)
CONTACTEUR
(VENTILATEUR)
(N/F
) 1
7 (COM)
(N/O) 4
(N/F
) 3
9 (COM)
(N/O) 6
VOYANT
DEGIVRAGE
5
3
1
6 (N/O)
4 (N/O)
2 (N/O)
21
22 (N/F)
CONTACTEUR
(COMP 1)
(W)
(V)
(U)
1
6 (N/F)
18 (N/O)
(COM) 15
A2
A1
TEMPORISATION T2
(6 MINS)
54
53 (N/O)
COMP 2 MCB AUX
16 (N/F)
13
14 (N/O)
13
14 (N/O)
DISJONCTEUR COMP 1
AUX
(SE COUPE A H EN
BASSE TEMPERATURE
L3
L2
L1
14 (N/O)
11 (COM)
5
3
1
CONTACT ALARME
DISJONCTEUR VENTILATEUR
CONTACT ALARME DISJONCTEUR
COMPRESSEUR 1
CONTACT ALARME DISJONCTEUR
COMPRESSEUR 2
L3 L2 L1
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
6 (N/O)
4 (N/O)
2 (N/O)
5
3
1
6 (N/O)
(N/O) 11
14 (COM)
21
(W)
5
3
6 (N/F)
4 (N/F)
(COM) 15
18 (N/O)
A1
A2
A2
A1
A1
A2
5
3
4 (N/F)
2 (N/F)
A1
A2
54
53 (N/O)
COMP 1 MCB AUX
(COM) 6
4 (N/O)
11
10
SONDE
5 (N/C)
(COM) 7
8 (N/O)
9 (N/F
)
2 (N
)
C (COM)
H (N/O)
(N/F) L
OUT 2
(SE COUPE A H EN BASSE
DE TEMPERATURE)
1 (L)
44
43 (N/F)
43
44 (N/F)
(N/F)
C (COM)
H (N/F)
(N/O) L
C (COM)
H (N/O)
(N/F) L
(SE COUPE A L EN
HAUTE PRESSION)
(SE COUPE A H EN
BASSE PRESSION)
(N/F)
95
96 (N/F)
(NF)
TK
TK
PROTECTION THERMIQUE
VENTILATEUR
PP(T)70EHC, TRIPHASEE (200V ~3 60Hz)
21
SD566250 ISSUE 35
Содержание Pro-Pac 140
Страница 1: ...Pro Pac system Pro Pac 30 45 70 90 140HC Owner installation manual SD566250 issue 35...
Страница 2: ...2 SD566250 ISSUE 35 PR0 PAC SYSTEM OWNER INSTALLATION MANUAL...
Страница 50: ...50 SD566250 ISSUE 35 PR0 PAC SYSTEM OWNER INSTALLATION MANUAL...
Страница 51: ...51 SD566250 ISSUE 35...
Страница 54: ...2 SD566250 ISSUE 35 SYSTEME PRO PAC MANUEL D INSTALLATION...
Страница 102: ...50 SD566250 ISSUE 35 SYSTEME PRO PAC MANUEL D INSTALLATION...
Страница 103: ...51 SD566250 ISSUE 35...