18. Replace front cover, turn on electrical supply and turn humidistat towards 
20%. (Unless remote humidistat fi tted, see note 15 above) unit fan will start, 
followed 6 minutes later by th e compressor.
20. It is recommended th at th e fan mode switch is set to continuous, as in 
cycle mode th e fan and heaters only run togeth er if th ere is a demand for 
dehumidifi cation.

Safety thermostat
press to reset
(red button)

FIG 3

MODEL

DH30A & 
DH30AX

DH30AP & 
DH30AXP

DH30ARH

DH33A & 

DH33AX

DH33ARH

DH50A & 

DH50AX

DH50AP & 

DH50AXP

DH50ARH

DH55A & 

DH55AX

DH55ARH

SUPPLY

230V 50Hz

FUSE

Amps

10

20

10

10

10

13

32

13

13

13

NOMINAL RUNNING 
AMPS

Amps

3.4

11.7

3.4

3.4

3.4

5.6

22.3

5.6

5.6

5.6

FULL LOAD AMPS

Amps

4.4

12.7

4.4

4.4

4.4

7.5

24.2

7.5

7.5

7.5

COMPRESSOR LRA

Amps

15.8

15.8

15.8

15.8

15.8

30

30

30

30

30

AIR FLOW

m

3

/h

700

700

700

440

440

1280

1280

1280

740

740

NOISE LEVEL @3m

dB/A

52

52

52

48

48

56

56

56

48

48

WATER FLOW RATE

L/min

n/a

n/a

10

n/a

10

n/a

n/a

14

n/a

14

PRESSURE DROP

m hd

n/a

n/a

1.6

n/a

1.6

n/a

n/a

1.5

n/a

1.5

LPHW FLOW RATE

L/min

n/a

n/a

n/a

5.0

5.0

n/a

n/a

n/a

5.0

5.0

LPHW PRESSURE 
DROP

m hd

n/a

n/a

n/a

1.1

1.1

n/a

n/a

n/a

1.8

1.8

LPHW VOLUME

Litres

n/a

n/a

n/a

0.5

0.5

n/a

n/a

n/a

0.85

0.85

DIMENSIONS
(UNPACKED)

HEIGHT

mm

655

655

655

655

655

655

655

655

655

655

WIDTH

mm

780

780

780

780

780

1245

1245

1245

1245

1245

DEPTH

mm

250

250

288

250

288

250

250

288

250

288

WEIGHT

kg

40

40

45

40

45

60

60

65

60

65

HERMETIC SYSTEM

REFRIGERANT 
CHARGE 
‘A’ DEHUMIDIFIERS

kg 

R407c

0.5

0.5

1.04

0.5

1.04

0.75

0.75

1.64

0.76

1.65

REFRIGERANT 
CHARGE 
‘AX’ 
DEHUMIDIFIERS

kg

0.5

0.5

N/A

0.5

N/A

0.8

0.8

N/A

0.8

N/A

R407c Global Warming Potential (GWP) 1774

'P' MODELS WITH RESISTANCE HEATER
16. Connect remote air th ermostat as shown above to mains in terminal 
block marked Remote Thermostat
17. Ensure safety th ermostat(s) below are set, ie push red button(s).