OWNER/INSTALLATION MANUAL

Thank you for choosing this product, which is designed 
for quiet and energy efficient operation. It is the ideal 
way to heat your pool in an environmentally friendly 
way.

This guide provides information needed to install and 
operate the product effectively. Please ensure you 
read this manual and use the correct installation and 
operating procedures. 

This manual is intended for installers and users� 
Read the entire manual before using the heat 
pump� Awareness of the correct operating 
procedure for the machine and any safety devices 
is important, to avoid damage or injury�

The appliance can be used by children aged from 8 
years and above and persons with reduced, physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision 
or instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without 
supervision. 

1�2 WARNINGS

Important safety information is contained in this manual 
and marked on the heat pump.

Please read and follow all safety advice�

The refrigerant used in this heat pump is R32*� 
This refrigerant is environmentally friendly, but 
safety instructions must be strictly adhered to� 

* The refrigerant used in the CPT20 is R410a�

The WARNING sign denotes a hazard� It calls 
attention to a procedure or practice, which if not 
adhered to could result in injury� Warning if signs 
and procedures must be complied with�

If a refrigerant leak is suspected stop using the 
heat pump and contact Dantherm Group UK 
service� 
service�department@dantherm�com

Take the following precautions in order to avoid 
any danger:

REFRIGERANT SAFETY:

This heat pump contains R32 refrigerant� Work 
on the refrigeration system, repair and disposal 
must be carried out by appropriately qualified and 
registered engineers� 

Repair, service and disposal must be carried out in the 
EU by F-Gas registered engineers.

Completely de-gas the refrigerant before any brazing 
is performed. Brazing can only be carried out by 
technicians trained to EU 517/2014. 

Risk assessments must be carried out before 
maintenance or repairs are started.

Appropriate safety measures and risk assessments 
must be taken before work commences.

Do not attempt to work on the equipment by 
yourself�

 

Consult the qualified engineer undertaking the work to 
establish all requirements before work commences.

1�0 INTRODUCTION

1�1 FOREWORD

Содержание C-PAC+ CPT6 ALY

Страница 1: ...C PAC swimming pool heat pumps CPT 6 8 12 15 20 Owner Installation Manual 1006905 Issue 2...

Страница 2: ...s This appliance can be used by children from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision...

Страница 3: ...N IN SWIMMING POOLS 16 3 7 ELECTRIC WIRING AND SUPPLY 16 3 8 CONNECTING THE HEAT PUMP TO THE POWER SUPPLY 17 3 9 POOL PUMP SYNCHRONISATION TERMINALS P1 AND P2 18 3 10 REMOTE ON OFF CONNECTION 19 4 0 U...

Страница 4: ...and follow all safety advice The refrigerant used in this heat pump is R32 This refrigerant is environmentally friendly but safety instructions must be strictly adhered to The refrigerant used in the...

Страница 5: ...e following location requirements must be fulfilled The heat pump must be kept away from sources of fire or naked flames The heat pump must be installed operated and stored where the floor area is lar...

Страница 6: ...up without warning Electric storms can damage electronic equipment Ideally the heat pump should be switched off at the mains HEAT PUMP MALFUNCTION WARNING Isolate heat pump electrically and wait 3 min...

Страница 7: ...nts may not contain an odour Appliance shall be installed operated and stored in a room with a floor area larger than Xm2 where X is the minimum area shown in section 3 2 and section 8 0 The heat pump...

Страница 8: ...eat pump by the water inlet or outlet connections If this is done the titanium heat exchanger inside the heat pump could be damaged 2 2 ACCESSORIES These accessories are provided with the heat pump 2...

Страница 9: ...at exchanger High pressure and low pressure protection Soft start and wide voltage application Multi function operation Can also be used for cool pools 2 4 OPERATING CONDITIONS AND RANGE Air temperatu...

Страница 10: ...absorbs energy from the air drawn through it To function effectively the heat pump must have access to the fresh air it needs Air must not recirculate The air leaving the heat pump must not be sucked...

Страница 11: ...rea or where required to pass air through a wall etc Ensure the heat pump is sealed against the wall so the outlet air cannot recirculate Ensure the hole through the wall is sealed to avoid the outlet...

Страница 12: ...WNER INSTALLATION MANUAL 350 cm Swimming pool or spa To comply with safety regulations regarding electrical installations in wet areas the heat pump must be installed at least 350cm away from the edge...

Страница 13: ...evel in a room stays below their lower flammability limit LFL European standard EN378 defines requirements to remain far below the lower flammable limit in case of accidental leakage By choosing the l...

Страница 14: ...tiser fitted Non return valve Sanitiser or chemical dosing device If fitted Aux heater If fitted Filter Pump To waste for winterising drain down 100mm Condensate water to waste Spare port for winteris...

Страница 15: ...must be supported to avoid excessive strain on the connections 4 Water quality must be maintained See warranty conditions 3 5 INITIAL CHECKS Start the filtration pump before the heat pump is turned o...

Страница 16: ...lectrical items such as metal filters pump strainer boxes heat exchangers steps and handrails It is highly recommended that bonding be retrofitted to existing pools which may not be protected by this...

Страница 17: ...within 2m and in line of sight of the heat pump Secure cables using cable clamps and feed through cable entry points in machine Isolator which disconnects all poles fitted within 2m and in line of si...

Страница 18: ...s If the pool does not need heating cooling the filter pump will be turned off after 5 minutes until the next sampling period or the next timeclock pump on period If the pool needs heating cooling the...

Страница 19: ...itch which are marked Remote on off and are situated below the mains in terminals The heat pump is supplied with a link wire in the remote terminals for use without a switch When fitting a remote swit...

Страница 20: ...mode Auto mode Fan running Heating mode 88 88 88 88 Current water inlet temperature SET IN Ambient temperature ROOM OUT Error codes show here Timer function enabled Timer function disabled Fault indi...

Страница 21: ...eat pump is defrosting the symbol will appear It will disappear when defrost is complete e Clock setting Press the to enter the timer settings The icon will flash Press M to set hour with p and q Pres...

Страница 22: ...eating Set temperature too low Set desired heating temperature 3 minutes start delay Wait for the delay timer to time out Inaccurate switch action Stop the machine and cut off the power supply immedia...

Страница 23: ...time when in standby to prevent frost build up This does not replace winterisation Heat pump will resume standby one process is completed 5 3 FAULT CODES No Display Description of fault code 1 P1 Eva...

Страница 24: ...Check bolts cables and connections regularly Repair service and disposal of redundant heat pumps must be completed by authorised technicians It is illegal to allow refrigerant gases to escape to air D...

Страница 25: ...67 4 6 Rated input current A 5 49 6 26 9 42 12 1 12 3 Maximum input current A 10 0 15 3 18 3 25 3 11 1 Rated RCD A 30mA 30mA 30mA 30mA 30mA Rated fuse aM MCB type C A 20 20 32 40 20 Sound pressure le...

Страница 26: ...on F H Pressure gauge J G Air inlet Air inlet D A B C Water Inlet A B C D E F G H J CPT6 ALY 381 620 363 405 968 370 96 654 741 CPT8 ALY 381 620 363 405 968 370 96 654 741 CPT12 ALY 466 750 443 490 11...

Страница 27: ...R CPT6 ALY 470 470 327 342 493 560 50 CPT8 ALY 470 470 327 342 493 560 50 CPT12 ALY 545 545 350 389 598 608 50 CPT15 ALY 545 545 350 389 598 608 50 CPT20 BLY 650 650 400 446 713 709 50 M N Water Inle...

Страница 28: ...ive To provide frost protection To eliminate corrosion problems To inhibit electrical components 1 Switch off electrical supply to heat pump 2 Remove external fuses and keep in safe place away from he...

Страница 29: ...icient or in any way incorrect 8 The fan amps and duct pressure are outside the specified limits 9 The air flow to and from the machine is outside the specified limits If in doubt or if advice is requ...

Страница 30: ...30 1006905 ISSUE 2 OWNER INSTALLATION MANUAL 12 0 DECLARATION OF CONFORMITY...

Страница 31: ...31 1006905 ISSUE 2...

Страница 32: ...Dantherm Ltd Unit 12 Galliford Road Maldon CM9 4XD United Kingdom 44 0 1621 856 611 sales uk dantherm com Calorex is a brand of danthermgroup co uk...

Отзывы: